3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are tted by a qualied
installer (see www.jotul.com for a complete list of dealers).
Any modications to the product by the distributor, installer or
consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning and
safety of the replace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
NB: Parts of the stove, in particular, the external surfaces, get
hot during combustion! Exercise caution!
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your replace. The following instructions must therefore be
followed:
• The minimum safety distances when installing and using
the replace are given in g. 1.
• Ensure that furniture and other ammable materials are
not too close to the replace. Flammable materials should
not be placed within 900 mm of the replace.
• Allow the re to burn out. Never extinguish the ames with
water.
• The replace becomes hot when lit and may cause burns
if touched.
• Only remove ash when the replace is cold. Ash can
contain hot embers and should therefore be placed in a
non-ammable container.
• Ash should be placed outdoors or be emptied in a place
where it will not present a potential re hazard.
In case of chimney re:
• Close all hatches and vents.
• Keep the rebox door closed.
• Check the loft and cellar for smoke.
• Call the re service.
• Before use after a re an expert must check the replace
and the chimney in order to ensure that it is fully functional.
Steel chimney
If a top-mounted steel chimney is used, t an uninsulated
pipe from the burn chamber to approx. 10 mm over the top
grate. Make sure that the gasket is properly seated between
the ue pipe and the smoke outlet. Then t the steel chimney
in accordance with the chimney supplier’s installation
instructions.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a replace.
See “2.0 Technical Data” for specied weight.
We recommend the removal of any ooring that is not attached
to the foundation (“oating oors”) beneath the installation.
Requirements for protection of
inammable oors in front of the
replace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions
and installation requirements.
3.3 Walls
Distance to walls made of combustible material - see g. b
Distance to combustible wall protected by rewall: See
g. 1c.
The replace may be used with an uninsulated ue pipe
provided the distances between the replace and walls made
of combustible materials are as shown in g. 1b. Alternative
distances with shielded or insulated ue pipe are also
displayed in g. 1b.
NB: Place the product in such a way that it is possible to clean
the stove, the ue pipe and the chimney passage.
Note! Ensure that furniture and other ammable materials
are not too close to the replace. Flammable materials
should not be placed within 900 mm of the replace.
NB: Make sure that furniture and other household items are
not so close as to get dried up by the stove.
3.4 Ceiling
The fireplace can be fitted with the top edge of the hot air
opening of the surround at least 750 mm below a ceiling
of inflammable material.