Operation Manual

4
550 mm
C
L
625 mm
705 mm
330 mm
475 mm
Jøtul GF 3 CF 2
Technical Information
With Short Legs, reduce height by 2 1/4” ( 51 mm)
Material: Cast iron/steel
Finish: Blue Black enamel or Matte Black paint
Flue outlet: Top or Rear
Vent system: BV-standard system
Weight: Approx. 71 kg (product)
PIN: 0063BS5908
Product dimensions: See fig. 1.
Figure 1. Top view dimensions.
Figure 2. Front view dimensions.
Figure 3. Side view dimensions.
705 mm
565 mm
C
L
292 mm
C
L
114 mm
420 mm
584 mm
Countries of Destination GB, IE
Appliance Category II
2H3P
Gas Types NG LPG
(G20)
1
(G31)
2
State of Adjustment I
2H
I
3P
Supply Pressure (mbar) 20 37
Nominal Heat Input (Nett, kW) 6.3 6.8
Maximum Gas Consumption at
Full Rate: (m
3
/h at 15°C 1013.25mbar) 0.666 0.278
Maximum Gas Consumption at
Full Rate: (kg/h at 15°C 1013.25mbar) - 0.528
Burner Pressure at Full Rate –
Hot (mbar): 9.10 26.9
Efficiency:
Rear Flue (Nett, %) 80.6 80.9
Top Flue (Nett, %) 79.9 79.5
Efficiency Class 2 2
NOx Class 5 5
Main Burner Injector Marking 235 140
Pilot Injector Marking 51 30
Notes:Notes:
Notes:Notes:
Notes:
The appliance is supplied at the default factory
settings for Natural Gas (G20 at 20mbar)
The appliance will have this setting following
conversion to LPG (G31 at 37mbar)