Jøtul GF 400 CF Conventional Flue Gas Stove Installation and Operation Instructions WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
Jøtul GF 400 CF INSTALLATION SIGNATURE FORM With proper usage and maintenance, this appliance will serve its owner adequately for many years. Please contact your Jøtul dealer for assistance if any problems should arise with your Jøtul appliance. Save this user manual and make sure it is available for service personnel. Annual service - year 8 Company: Sign.: Date: Annual service - year 9 Company: Sign.: Date: Annual service - year 10 Company: Sign.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION OF YOUR STOVE. PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS GAS STOVE. Table of Contents 1. Technical Information........................... 4 2. General Information..............................5 3. Safety Information..................................5 4. Installer Information............................. 6 5. User Information...............
Jøtul GF 400 CF Technical Information Material: Cast iron/steel Flue outlet: Top or Rear Finish: Vent system: Weight: PIN: CL CL 114 mm 330 mm Enamel or Matte Black paint BV-standard system Approx. 86 kg (product) 673 mm 0063BS5908 Figure 1. Top View dimensions. Product dimensions: See figs. 1, 2, 3.
General Information This product has been approved to the European Standard EN 613:2000 and is in accordance with EC Gas Appliances Directive (90/396/EEC). The Flue must be checked for soundness and swept prior to installation it should only be used if clean and in good order. Before installation, ensure that the local distribution conditions and the adjustment of the appliance are compatible.
Installer Information The Flue must be checked for soundness and swept prior to installation it should only be used if clean and in good order. 356 mm Before installation, check that the local distribution conditions, nature of the gas and pressure, and the adjustment of the appliance are compatible. Assembly, installation, maintenance and gas conversion (if required) must be performed by a qualified person in accordance with the instructions for assembly, Installation and use enclosed with the product.
��������������� ����������� ���������������� ���������������� 600 mm � � ������� ����� ����������� ������� ����� Figure 7. Clearance to a combustible shelf. Figure 8. Vent height requirements. Flue System Installation Closure Plate Installation Flue outlet (spigot) dimensions: Internally = 128 mm Externally = approx. 131 mm When installing the vent, it is important to adhere to national and local regulations that apply. Only one appliance may be connected to the vent system.
All brick flues or any flue previously used with solid fuel or gas appliances must be left with the appropriate debris collection volume below the flue spigot of the stove of 12 litres minimum, and depth of 250 mm minimum below the spigot as shown in fig. 9.
Logset Installation Brick Kit Note: Install the optional Antique Brick Kit 155375 before installing the log set. See instructions supplied with that kit. The GF 400 CF log set must be installed before operating the burner. The log set includes four log pieces, packaged inside the firebox, and a quantity of ceramic embers. To install the log set, remove the packaging and place the parts inside the firebox as illustrated in the diagrams below. Do not handle the log set with your bare hands.
Gas Installation Gas installation must only be performed by qualified personnel. It is important to adhere to national and local regulations that apply. In the UK these include BS5440 Pt 1&2 and BS5871 in Ireland. The LPG gas container must be stored/installed according to national regulations. The gas container must have a pressure regulator that reduces the pressure to the required level. See technical data on page 4 for gas type and pressures before connecting to the appliance.
Figure 19. The thermocouple and thermopile should be fully engulfed by the pilot flames. �� ������ ���� ����� ���� ���� ����� ���� See Air Shutter detail below. Adjusting the Burner Burner adjustments must only be performed by qualified personnel. To adjust the air supply, loosen the right wingnut located under the stove next to the fuel line. See fig. 20. Adjust the air opening by pulling the air shutter to the correct air inlet opening. See fig. 21. For Natural Gas: 21.
User Information General Assembly, installation, maintenance and gas conversion (if required) must be performed by a qualified person in accordance with the instructions for assembly, Installation and use enclosed with the product. The installation may only be operated after it has been inspected by a qualified person and a certificate of completion has been issued.
B ������ ����� ��� �� A D E C Figure 23. Valve Controls. Figure 24. Burner Switch location. 4. Push in the gas control knob (B) as far as possible and hold it in. Simultaneously, push in the ignition knob (A) until the spark ignites the pilot flame located to the right rear corner of the burner. Adjusting the Heat Setting 5. Continue to hold in the gas control knob for approx. 20 seconds after the pilot flame has been lit. Then let go of the knob.
Troubleshooting � � When No Spark is Generated at the Pilot Head It is uncommon for the Piezo spark ignitor (fig 25-A) to fail, unless it has mechanical damage. If the spark is not conducted forward, it could be the result of a break in the electrical circuit leading up to the pilot head. The spark is small or weak if there is too much resistance from a bent wire (E), or if corrosion appears at the electrode (G) or the pilot head (H). This could result in insufficient heat to light the gas.
When There is No Gas Flow To The Pilot Head This is the trouble-shooting procedure for the gas supply: Check if all gas connections are sealed by using strong soapy water (avoid synthetic soaps). Be certain all valves from the gas tank/cylinder are fully open. When the pilot is to be lit for the first time with a new installation, after a scheduled disconnection or after the propane tank has been refilled, there will often be air in the gas tube leading up to the appliance.
Make sure the flame is centred at the thermocouple. Make sure the thermocouple is enveloped by the flame up to at least 3 mm from the tip (see fig.20). Check the voltage generated by the thermocouple. Connect the multimeter (fig.26-E) with plus to the ball point (D) at the end of the copper wire. Connect minus to the copper wire. Light the pilot (A) and hold in the control knob to prevent the flame on the pilot burner from going out. At this point the multimeter should show 14-28 mV. the thermocouple.
Problems With the Flame Pattern Tall, narrow, yellow flames These flames can soot the vent system and may be the result of insufficient oxygen supply. Check for correct air volume by measuring the opening (fig.22) at the air shutter. Correct opening dimensions are normally: Burner Orifice For Propane - Open 18.5 mm For Natural Gas - Open 21.5 mm Warning! To avoid burns, do not adjust the air opening until the burner has cooled down. Blocked orifice: Make sure the main orifice (fig.
Figure 29. �� �� � � � � � � � � � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � � �� �� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� ONLY USE REPLACEMENT PARTS PROVIDED BY AN AUTHORIZED JØTUL DEALER.
Jøtul GF 400 CF Parts List Blue Black Ivory Cast Iron Parts Matte Black Enamel Enamel 10. 30. 47. 55. 57. 60. 74. 1. 2. 3. 4. 5. 6. 7. 8. 9. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40.
January 2009 138783 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications. Jøtul vise sans cesse a ameliorer ses produits.