Use Instruction

PREDICTIVE DIGITAL THERMOMETER
OWNER S M ANUAL
Model:DMT-4760b
Warning :
Read instructions thoroughly before using digital thermometer.
Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children
to use this device without parental supervision.
Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only.
Do not place thermometer battery near extreme heat as it may explode.
Remove battery from the device when not in operation for a long time.
The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the
interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions.
Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
Do not bite the thermometer. Doing so may lead to breakage and/or injury.
Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
After each use, disinfect the thermometer especially in case the device is used by more than one person.
Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is
present. Failure to do so may lead to injury.
Do not use thermometer orally after being used rectally.
For children who are two years old or younger, please do not use the devices orally.
If the unit has been stored at temperatures over ( ), leave it in
(540℃) ambient temperature for about 15 minutes before using it.
41104 540 41104
CONTENTS
1 Thermometer, 1 Owner s Manual, 1 Storage Case
PLEASE READ CAREFULLY BEFORE USING
The predictive digital thermometer provides a quick and highly accurate reading of an individual's
body temperature. Predictive-read thermometers are quicker than actual read thermometer.
Predictive read type thermometers display the temperature results in a short period of time which
are equivalent to balance temperature after 5 minutes according to the particular algorithm.
Therefore, users only need about 5 seconds to take the temperature readings. Due to measurement
sites of predict thermometer are different, the reading time also may be different, but the actual time
is usually between 5 and 10 seconds. (See below Figture 1)
Predict Result
Temperature
5 to 10 seconds
5 min
Balance temperature
Time
Start
Actual Result
Actual temperature
3 min
Figure 1
/ SWITCHABLE
Temperature readings are available in the Celsius or Fahrenheit scale (/; located in the upper right
corner of LCD.) With the unit off, press and hold the On/Off Button for approximately 3 seconds to
change the current setting.
SPECIFICATIONS
89.6-111.0 32.043.9( )( / chosen by manufacturer)
± ( ) during ( ) at
( ) ambient operating range
( ) for other measuring and ambient operating range
0.2 ±0.1 95.9~107.6 35.5~42.0
64.4~82.4 18~28
±0.4 ±0.2
Measure Range:
Ambient operating range:
Storage and transportation
condition:
Liquid crystal display, 3 ½ digits
The last ten memories
One 3.0V DC button battery type CR2032
Temperature: ( )41104 540
Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa
Temperature: ( )-4131 -20~55
Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa
Classification:
Type:
Digital Thermometer (Predictive)
Type BF
Ingress Protection Rating:
IP 27
Accuracy:
Display:
Memory:
Battery:
Battery life:
Dimension:
Weight:
Expected service life: Three years
Operating mode: Adjusted mode: Oral mode/Rectal mode/Underarm mode
Direct mode: Bath mode
Eight month with 3 measurements per day
13.6cm×3.8c1.7cm(L x W x H)
Approx. 28 grams including battery
The digital thermometers are intended to measure the human body temperature in regular
mode orally, rectally or under the arm. And the devices are reusable for clinical or home use on people of
all ages, including children under 8 years old with adult supervision.
Indications For Use
TROUBLESHOOTING
measurement
is excess 15 seconds.
The time of predictive
·
measure at high temperature.
·Person may be just drank cold drinks, repeat
measurement wait for 15mins.
·The thermometer is moved when measuring, Do
not move, and then repeat measurement.
The ambient temperature may be too low, please
functioning properly.
The thermometer is not
If the message reappears, contact the retailer for
service.
Unload the battery, wait for 1 minute and repower it.
Err messages
Other
Problem
Solution
Error message
The thermometer is moved
when measuring.
Do not move, and then repeat measurement.
Temperature taken is
lower than 89.6°F(32.0°C)
Turn off, wait one minute and take a new temperature
via close contact and sufficient rest.
Temperature taken is
higher than 111.0°F(43.9°C)
Dead battery: Battery icon is
flashing, cant be measurable.
Replace the battery.
Turn off, wait one minute and take a new temperature
via close contact and sufficient rest.
Figure 12
Figure 11
CALIBRATION
The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to
the use instruction, periodic readjustment is not required. However, we recommend checking calibration
every two years or whenever clinical accuracy of the thermometer is in question. Turn on the thermometer
and insert into the water bath and then check the laboratory accuracy. Please send the complete device to the
dealers or manufacturer. ASTM laboratory accuracy requirements in the display range of 98.6 to 102.2 °F
( ) for electronic thermometers is ( ).37.0 to 39.0 °C ±0.2°F ±0.1°C
The above recommendations do not supersede the legal requirements. The user must always comply with
legal requirements for the control of the measurement, functionality, and accuracy of the device which
are required by the scope of relevant laws, directives or ordinances where the device is used.
CLEANING AND DISINFECTION
2)Using a clean, soft cloth to wipe the thermometer down to remove any residue;
3)Repeat step 1 and 2 for three times until no soil is seen with visual inspection after cleaning;
4)For thoroughly clean and disinfection, please use method A or B
Method A(High level disinfection): immerse the thermometer probe in 0.55% OPA(O-Phthaldehyde),
such as CIDEX OPA, for at least 12 minutes under temperature at 68℉;
Method B(Low level disinfection): Using a clean soft cloth dipped in 70% medical alcohol, wipe the probe
3 times,at least one minute for each time.
5)Repeat step 1 to 3 to remove OPA residuals;
Note1: Rectal use is not recommended for home use as OPA will not be readily available outside of a hospital.
If rectal measurement is necessary, we strongly recommend high level disinfection.
Note2: Please operate according to the manual of OPA for reference.
To prevent damage to the thermometer please note and observe the following:
-Do not use benzene, paint thinner, gasoline or other strong solvents to clean the thermometer.
-Do not attempt to disinfect the sensing probe (tip) of the thermometer by immersing in alcohol, OPA
or in hot water (water over 122(50) for long time.
-Do not use ultrasonic washing to clean the thermometer.
1)Immerse the thermometer probe in distilled water for at least 1 minute;
PRODUCT ILLUSTRATION
Figure 2
On/Off Button
LCD
Probe
SELECT MODE
1. Power on the thermometer.
2. During the mode displays, press and hold the On/Off button until mode flashing.
3. Press the button again to cycle through the four mode options (see figure 3).
4. When the desired mode displays on screen, wait for auto entering into measurement mode.
Figure 3
Oral mode
Rectal mode
Underarm mode
bath mode
Figure 13
BATTERY REPLACEMENT
1. Replace battery when appears in the lower right corner of LCD display.
2. Put a thin board such as a coin on fillister of cover. Turn the battery anti-clockwise until the cover is off
(See Figure 11).
3. Use a non-meteal instrument such as a pen to remove old battery from the battery holder (See Figure 12).
Discard battery according to local law.
4. Place a new into the chamber with positive side facing up(See Figure 13).
5. With a thin pin to turn the cover clockwise until the facing towards (See Figure 14)
3.0V DC CR2032
Figure 14
MEMORY MODE
check the last 10 memories.
1. Power on the thermometer.
2. During the last memory displays, press and hold the On/Off button until entering into
Memory Mode.
3. Press the button again to cycle
4. Long press the On/Off button for 3 seconds to quit the memory mode.
Bluetooth requirements
1.
2.
The Glucose Meter requires a bluetooth device with:
* Bluetooth 5.0.1 *Android 6.0 or later *IOS 10.0 or later.
And works with: . iphone , iPod, iPad . Android Phones and Tablets.
3. Position thermometer in desired location (mouth, rectum, or armpit.)
a) Oral Mode: Place thermometer under tongue as indicated by
position shown in Figure 7. Close your mouth and breathe evenly
through the nose to prevent the measurement from being influenced
by inhaled/exhaled air.
b) Rectal Mode: Lubricate silver probe tip with petroleum jelly for easy insertion. Gently insert
sensor approximately 1cm (less than 1/2 ") into rectum.
c) Underarm Mode: Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.
From a medical viewpoint, this method will always provide inaccurate readings, and should not
be used if precise measurements are required.
d) Bath Mode: It will display Lo and then or is still flashing( ), then place
probe tip into bath water.
Note: The accuracy of unit must be tested using water bath in bath mode.
4. The three dashes (---) will flash sequentially throughout the testing process, and at the same time
the “ ” are flashing(See Figure 8).When flashing stops an alarm will beep for approximately 10
seconds. The predictive measured reading will appear on the LCD simultaneously(
see Figure 9).The measurement time of the oral/underarm/rectal mode varies with the
individual, which are between 5 and 10 seconds.
:The minimum measurement time of Bath Mode until the signaling tone (beep) must be
maintained without exception.
5. The thermometer will enter into the Actual Measurement after 3 minutes except Bath Mode,At the
same time you can hear two beeps as a cue ( The “ ” will disappear and the Actual measurement
temperature display see Figure10), users can take the true body temperature at this time. Users can
compare the predictive temperature result with true temperature result. In order to achieve better body
temperature measurement result, recommend to keep the probe in mouth and rectum about 2 minutes,
or in armpit about 5 minutes regardless of the beep sound and at least 30 seconds measurement
intershould be maintained.
6. To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no action
is taken, the unit will automatically shut off after around10 minutes.
7. Store the thermometer in its protective case.
See Figure 6
For example
98.6
*Note
*Note: Normally Alarm b eeps m ore ra pidly w hen te mperature
reaches 100.0 (37.8 ) or higher ,and t
the buzzes are Bi-Bi-Bi- B i-;
he buzzesare Bi-Bi-Bi--- Bi-Bi-Bi--- Bi-Bi-Bi
Figure 7
DIRECTIONS
followed by last recorded temperature. After showing the mode of measurement(See Figure 3), the
thermometer will enter into the testing mode(Oral/Underarm/Rectal mode see Figure 5 or
Bath Mode see Figure 6).
2. Press the On/Off Button next to LCD display. A tone will sound as the screen shows(See Figure 4) ,
Figure 4
Figure 5
Figure 6
Figure 10
1. Please download and install “JoyHealth” APP from Website or APP Store (Such as Apple Store),before
using this product. Then use your email account to register a new account and log in. Selection
thermometer” device,And turn on your phone's Bluetooth.
Figure 9
Figure 8
LIMITED WARRANTY
The thermometer is guaranteed for one year from the date of purchase. If the thermometer does not
function properly due to defective components or poor workmanship, we will repair or replace it free of
charge. All components are covered by this warranty excluding the battery. The warranty does not cover
damages to your thermometer due to improper handling. To obtain warranty service, an original or copy
of the sales receipt from the original retailer is required.
Disposal of this product and used batteries should be carried out
in accordance with the national regulations forthe disposal of
electronic products.
Document No. JDMT-8304-038
Article No.: 001
Version: Z
Date of Issue: 202X.XX
JOYTECH HEALTHCARE CO.LTD.
No.365, Wuzhou Road, Yuhang Economic Development Zone, Hangzhou city
, 311100 Zhejiang,China Tel:+86-571-81957767
Made in China
PRECAUTION
*The performance of the device may be degraded should one or more of the following occur:
- Operation outside the manufacturer’s s tated te mperature and humidity range.
- Storage outside the manufacturer’s s tated te mperature and humidity range.
- Mechanical shock (for example, drop test) or degraded sensor.
- Patient temperature is below ambient temperature.
*Portable and mobile RF communications can affect the device. The device needs special pre-cautions
regarding EMC according to the EMC information provided in the accompany documents.
*Do not use the devices in the MR environment.
Batch Code
Manufacturer
Storage and Transportation
Temperature Limit: -4131
(-20~55℃)
-4
131
SYMBOL EXPLANATION
Direct Current
Type BF Applied Part
Consult Accompanying Documents
Note: If temperature below , the triangular arrow will not display.96.4 35.8( )
FEVERLINE INDICATING TECHNOLOGY
different temperature range.
At the completion of each measurement, the triangular arrow on the display will indicate according to
For example:
Triangular arrow explain:
96.4 T99.1 35.8 T37.3( )
99.1 T100.0 37.3 T37.8( )
T100. 0 T37.8( )
The system is not
functioning properly.
Unload the battery, wait for 1 minute and repower
If the message reappears, contact the retailer for service.
it.
use the APP to bind the thermometer deviceAfter successful connection, the “ ” will stop flashing
and continue to be visible.
3. When you see the LCD display “ ” flashing, it means that the thermometer is waiting for Bluetooth connection, you only
have 60 seconds to
APP will be synchronized with the thermometer.
490.00 mm
The first num.2:Protercted against access to hazardous parts with a finger,and the jointed test
finger of 12mm φ,80 , 80 mm length, shall have adequate clearance from hazardous parts .
And protected against solid foreign objects of 12,5 mm Ф and greater. The second number 7:
Protected against water and the test is made by completely immersing the enclosure in water
between 0.15m and 1m for about 30 minutes. The water temperature does not differ from
that of the equipment by more than 5 K.
IP 27
FCC INFORMATION
Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user authority to operate the equipment. This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
*Note:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the distance between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
124.00 mm
The device has been evaluated to meet general RF exposure requirement.The device can be used in portable
exposure condition without restriction.

Summary of content (3 pages)