User's Guide

©JRI 8
LoRa® SPY TH1 - Thermo-Hygro Internal
HIM
: 1 RGB LED + 1 touch-sensitive button + 1 LCD display
Communication
: LoRa® 868MHz or 915MHz*
Memory
: 10 000 time-stamped measurements
Sensor
: Inside control unit
Operating range
: -30+70°C
Measurement range
: -30+70°C and 0 100% RH
Accuracy, standard version
Temperature
Humidity at T° between 15 and 25°C
: ± 0.4°C from -20 to +40°C / ± 0.5°C outside this range
±2% HR from 20% to 80%
±4% HR from 0 to 20% and 80% to 100%
Resolution
: 0.01
IP rating
: IP 40
Frequency of recording and
transmission
: adjustable from 1 min to 24h (15 min in standard use)
Frequency of measurement
: 1 or 5 min
Response time
: ~ 5 min. to 90% of the variation
Power source
: 3,6V Lithium battery 2 to 4 years autonomy depending
on use
Case
: Polycarbonate Food safe
Dimensions
: 87 mm x 64 mm x 25 mm
Weight
: ~ 100g
LoRa® SPY N Digital
HIM
: 1 RGB LED + 1 touch-sensitive button + 1 LCD display
Communication
: LoRa® 868MHz or 915MHz*
Memory
: 10 000 time-stamped measurements
Sensor
: External to control unit
Operating range
: -30+70°C
Measurement range
: according to the type of JRI digital probe
Accuracy, standard version
: Accuracy of the JRI digital probes
Resolution
: 0.01
IP rating
: IP 40
Frequency of recording and
transmission
: adjustable from 1min to 24h (5min in standard use)
Frequency of measurement
: 1 or 5 min
Response time
: Depending of the digital probe used
Power source
: 3,6V Lithium battery 2 to 4 years autonomy depending
on use
Case
: Polycarbonate Food safe
Dimensions
: 87 mm x 64 mm x 25 mm
Weight
: ~ 100g
LoRa® SPY TH3 Precision Thermo-Hygro
HIM
: 1 RGB LED + 1 touch-sensitive button + 1 LCD display
Communication
: LoRa® 868MHz or 915MHz*
Memory
: 10 000 time-stamped measurements
Sensor
: External to control unit
Operating range
: -30 +70°C
Probe measuring range
Standard
Industrial
: -40 +60°C and 0-100%HR
: -100 +200°C configurable and 0-100%HR
Probe accuracy at 23°±0,5°C
Standard
Industrial
Temperature : ± 0,1°C / Humidity : 0,8%RH
Temperature : ± 0,2°C / Humidity : 0,8%RH
Resolution
: 0.01
IP rating
: IP 40
Frequency of recording and
transmission
: adjustable from 1min to 24h (5min in standard use)