User's Manual

(2) CURBTX Option Setting
The option setting must be done prior to powering up.
As shown in the photo above, there are two option switches inside the CURBTX unit. The
switch on the left is to select a parking space (line) among the 16 spots assigned in the
PC program, and the one on the right is to add additional options.
(The current setting value in the picture above is “1000”, “0000”.
The first left pin of the switch on the right is for ultrasonic sensor range extension.
If it is0 as shown in the picture, the sensor detects an object within the range 2.8m.
Switching to “1” will extend the range.
The second left pin of the switch on the right is to put the unit in test or normal modes.
As shown in the picture,0 is the normal mode, and the sensor starts detecting on
every pre-set wakeup time when the pin is switched to “1”.
To assign a certain praking space (line) among the 16 spots, make following
combinations by switching each pin of the left switch.
“0000” (#1), “0001” (#2), “0010” (#3), “0011” (#4), “0100” (#5), “0101” (#6), “0110” (#7),
“0111” (#8), “1000” (#9), “1001” (#10), “1010” (#11), “1011” (#12), “1100” (#13), “1101”
(#14), “1110” (#15), “1111” (#16)
Power Switch (ON/OFF)
Option Setting