User's Manual

© Copyright 2014, HME Wireless, Inc. www.hmewireless.com | 800-919-9903 10 of 21
o This second test will ensure that objects below
table top level like walls, booth seats or
adjacent high top tables do not adversely
affect the previous test.
o Adjust ReferenceTag placement by hand until
the desired results are achieved.
o It is not necessary to test every inch of the
tabletop but it is important to factor where a
guest may place a GuestTag when waiting.
Once you are comfortable with the location of the
Reference Tags and have an understanding of what area
will display on screen, the test is complete.
Return the GuestTags to the Deactivate area to clear the
records on screen.
MOUNTING
When all testing is complete and you are satisfied with the
results and location of each of the Reference Tags it is time to
mount them. Each ReferenceTag is comprised on three
pieces; the mounting plate which mounts to the table or
object, the face or bottom plate, and the tag or bubble. The
face plate and tag snap into the mounting plate on it is on
the table or object.
For wood tables and objects: place mounting plate onto
object and secure to table. Only two screws are
necessary to ensure a quality installation, additional
screws can be added as desired. HMEW will provide an
allotment to install two screws with each tag.
For wire mesh patio tables: if possible, HMEW recommends
mounting the ReferenceTag on the table top. If not
possible, utilize two plastic zip ties (included) to secure the
mounting plate to the table. Once secured snap in the
ReferenceTag (may require a bit or force) and trim the
excess ends of the plastic ties.
For solid metal or dense surfaces (concrete, marble): these
surfaces will cause significant deflection of the RFID signals
and HMEW does not recommend mounting the
ReferenceTag underneath these types of surfaces.