User Manual

11
3 Mounting
3.3 Side-by-side mounting
3.4 Fitting in position
Type 703042/43/44 h Fit the seal that is supplied onto the
instrument body.
h Insert the controller from the front into
the panel cut-out.
h From behind the panel, slide the
mounting brackets into the guides on
the sides of the housing.
The flat faces of the mounting brackets
must lie against the housing.
h Push the mounting brackets up to the
back of the panel, and tighten them
evenly with a screwdriver.
Type 703041 h Fit the seal that is supplied onto the
instrument body.
h Insert the controller from the front into
the panel cut-out.
h From the back of the panel, push the
mounting frame onto the instrument
body and press it against the back of
the panel, compressing the springs,
until the latches snap into the notches
provided and it is firmly fixed in position.
Care of the front
panel
The front panel can be cleaned with normal commercial washing, rinsing and cleaning
agents. It has a limited resistance to organic solvents (e.g. methylated spirits, white
spirit, P1, xylol etc.). Do not use high-pressure cleaning equipment.
Minimum spacing of panel cut-outs
Type horizontal vertical
without setup plug:
703041 (48mm x 48mm)
703042 (portrait format: 48mm x 96mm))
703043 (landscape format: 96mm x 48mm)
703044 (96mm x 96mm)
11mm
11mm
30mm
11mm
30mm
30mm
11mm
30mm
with setup plug (see arrow):
703041 (48mm x 48mm)
703042 (portrait format: 48mm x 96mm))
703043 (landscape format: 96mm x 48mm)
703044 (96mm x 96mm)
11mm
11mm
65mm
11mm
65mm
65mm
11mm
65mm