Accuracy
Auxiliary power
Approvals/marks of conformity
Relative pressure Nominal measuring ranges start at 0 bar.
Nominal measuring range 0,4 1 4 10 25 60 bar
Linearity
a
a
Linearity based on limit point setting
0.15 0.15 0.1 0.1 0.1 0.1 % of FS of NMR
Accuracy at +20°C
b
b
Includes: linearity, hysteresis, repeatability, deviation from initial and final values of measuring range
0.35 0.3 0.25 0.25 0.25 0.25 % of FS of NMR
Accuracy at -20 to +75°C
c
c
Includes: linearity, hysteresis, repeatability, deviation from initial and final values of measuring range, thermal effect on initial value of measuring range and span.
0.7 0.6 0.5 0.5 0.5 0.5 % of FS of NMR
Nominal measuring range -0.4 to 0.4 -1 to 1 -1 to 3 -1 to 9 -1 to 24 bar
Linearity
a
0.15 0.15 0.1 0.1 0.1 % of FS of NMR
Accuracy at +20°C
b
0.35 0.3 0.25 0.25 0.25 % of FS of NMR
Accuracy at -20 to +75°C
c
0.7 0.6 0.5 0.5 0.5 % of FS of NMR
Absolute pressure Nominal measuring ranges start at 0 bar.
Nominal measuring range 0.4 1 4 10 25 60 bar
Linearity
a
0.15 0.15 0.1 0.1 0.1 0.1 % of FS of NMR
Accuracy at +20°C
b
0.35 0.3 0.25 0.25 0.25 0.25 % of FS of NMR
Accuracy at -20 to +75°C
c
0.7 0.6 0.5 0.5 0.5 0.5 % of FS of NMR
Long-term stability
d
d
EN 61298-1
0.2% of FS of NMR per year
Supply voltage UB
a
a
Residual ripple: Peak voltages must not exceed or fall below the values specified for the supply voltage!
Nominal voltage 24 V DC
0 - 20 mA, three wires, output 476 12 - 30 V DC
4 - 20 mA, three wires, output 475 12 - 30 V DC
0 - 10 V, three wires, output 477 14 - 30 V DC
Less than the permitted
supply voltage
Display Err 5
More than the maximum
supply voltage > 34 V DC
The specified properties are no longer met.
Reverse polarity protection YES
Power consumption 45 mA without load, 545 mA with load 2 x PNP
Electrical connection Round plug M 12 x 1, 4-pin, A-coded (for assignment see page 6, “Connection diagram”)
Circuit SELV
Mark of conformity Testing laboratory Certificate/certification
number
Test basis valid for
EHEDG TUM MAK No. 03/2006 Document No. 8 Process connection 997
JUMO PEKA