Block diagram
Connection diagram
Output 470 Output 471 Outputs 475 - 477
1 PNP switching output 2 PNP switching outputs 1 PNP switching output + 1 analog output
Power supply Power
supply
Power
supply
1 L+ 12 - 30 V DC 1 L+ 12 - 30 V DC 1 L+ 12(14) - 30 V DC
3 L- GND 3 L- GND 3 L- GND
Output Output Output
4 K1 High side open collector
max. 250 mA
2 K2 High side open collector
max. 250 mA
2 analog 0(4) - 20 mA / 0 - 10 V DC
2 nc 4 K1 4 K1 High side open collector
max. 250 mA
5 Interface 5 Interface 5 Interface
Color assignment: M12x1 round plug 1 bn Brown 4 bk Black The color assignment applies only
to A-coded standard cables !
2 wh White 5 gy Gray
3 bu Blue
Type
405052
Pressure
Voltage supply
12(14) ... 30 V DC
Switching output 2
Open collector
max. 250 mA
Interface
Set-up program
Display
2 x 4 characters, 2-color
Analog output
0 (4) ... 20 mA or
0 10 V DC
Switching output 1
Open collector
max. 250 mA
Shaft encoder
Operation: turning and pressing
1
2
3
4
5
L-
K1
L+
1
2
3
4
5
L-
K1 K2
L+
1
2
3
4
5
L-
K1
L+