User Manual

9
3 Identifying the instrument version
(5) Process connection
Not front-flush
504 G 1/2
511 1/4-18 NPT
521 G 1/4 to DIN 3852 T11
523 G 1/2 to DIN 3852 T11
998 Suitable for connecting to pressure measuring instrument
Front-flush
571 G 3/4
575 G 3/4 seal positioned in front
576 G1 seal positioned in front
603 Tapered adapter with groove nut, to DIN11 851, DN20
4
604 Tapered adapter with groove nut, to DIN11 851, DN25
4
606 Tapered adapter with groove nut, to DIN11 851, DN40
4
607 Tapered adapter with groove nut, to DIN11 851, DN50
4
612 Clamp to DIN 32 676, DN20
4
613 Clamp to DIN 32 676, DN25
4
616 Clamp to DIN 32 676, DN50
4
623 Small flange connection
4
652 Tank connection with groove union nut
4
, DN25
997 JUMO PEKA (EHEDG-certified)
3
998 Suitable for connecting to pressure measuring instrument
(6) Process connection material
20 Stainless steel 316L
(7) Electrical connection
36 Round plug M 12 x 1
(8) Measuring system filling medium
01 FDA-compliant oil
99 Special filling medium
(9) Extra codes
000 None
591 Throttle in pressure channel
624 Free of oil and grease
691 Cast version
(1) (2) (3) (4) (5) (6) (7) (8) (9)
Order code /------/
Sample order 405052 / 000 - 459 - 471 - 504 - 20 - 36 - 1 / 000
3
For matching process connection adapter see data sheet 40.9711
4
For measuring ranges up to 25 bar only