Instruction Manual

2013-03-15/00485234
Data Sheet 603070 Page 4/15
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
E-mail: mail@jumo.net
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax: +44 1279 635262
E-mail: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax: 315-437-5860
E-mail: info.us@jumo.net
Internet: www.jumousa.com
Operating data
Approvals/approval marks
Wiring diagrams
Switching point accuracy TR, TW STW, STB with a setting range of:
+20 °C to +80 °C +70 °C to +130 °C
Switching differential
2.5%
In the
"first half"
(+20 °C to +50 °C)
In the
"second half"
(+50 °C to +80 °C)
In the
"first half"
(+70 °C to +100 °C)
In the
"second half"
(+100 °C to +130 °C)
In the upper third of
the scale ± 3 %,
at scale
beginning ± 6 %
+0/-8 K +0/-5 K +0/-12 K +0/-5 K
Temperature compensation When the ambient temperature on the switching head and the capillary deviates — from the calibration ambi-
ent temperature of +22 °C — a switching point offset of approx. -0.1 K/K occurs
(switching point change referring to the ambient temperature change, measured at limit value +120 °C perma-
nently set and capillary length 2,000 mm).
This switching point offset is reduced to a minimum due to the standard temperature compensation.
Limit value temperatures For transport and storage: -30 °C to +50 °C
During use: max. +80 °C, for TZ 061 UL approval max. +65 °C
(type 7 max. 55 °C; type 6+8 max. +50 °C)
For pipe mounting: max. pipe temperature +120 °C
Rated position According to DIN 16257, rated position 0 to rated position 90 (different rated positions upon request)
Approval marks Inspection
authority
Certificates/certification
number
Inspection basis Valid for
DIN DIN CERTCO TR1191, TW1192,
STW(STB)1193, STB1194,
ATW1218
DIN EN 14597 JUMO heatTHERM-AT/-DR
according to type
DIN TÜV Süd
(German
Technical
Inspection
Agency)
DIN EN ISO 13849-1 B
10d
= 250,000* JUMO heatTHERM-AT/-DR
DGRL TÜV Süd
(German
Technical
Inspection
Agency)
IS-TAF-MUC 07113377017 Pressure Equipment Directive
97/23/EC
STW and STB
UL UL Germany E 66358 UL 873 JUMO heatTHERM-DR
* For further details see: Safety manual JUMO heatTHERM (-AT), (-DR) 602031, 603070.
Contact rating check conducted at 16 A, 230 V, resistive load.
TR, TW, STW STB