Technical data
Analog inputs
RTD temperature probe
Thermocouples
Direct current
Analog output
Designation Measuring range Accuracy
Two/three-wire circuit
1
Ambient temperature influence
Pt100 DIN IEC 60751:2008 -200 to +850 °C 0.5 %/0.1 % 50 ppm/K
Pt1000 DIN IEC 60751:2008 -200 to +850 °C 0.5 %/0.1 % 50 ppm/K
Connection type Maximum line resistance in two-wire circuit: 15 Ω; three-wire circuit: 30 Ω
Sampling rate 210 ms
Error tolerance time 5 s: time taken into account for all diagnostic tests
Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100 s
Special features Individual probe Pt100 two-wire,
display can also be programmed in °F
Designation Measuring range Accuracy
1
Ambient temperature
influence
Fe-CuNi "L" DIN 43710:1985-12 -200 to +900 °C 0.4 % 100 ppm/K
Fe-CuNi "J" DIN EN 60584-1:1996-10 -200 to +1200 °C 0.4 % 100 ppm/K
Cu-CuNi "U" DIN 43710:1985-12 -200 to +600 °C 0.4 % 100 ppm/K
Cu-CuNi "T" DIN EN 60584-1:1996-10 -200 to +400 °C 0.4 % 100 ppm/K
NiCr-Ni "K" DIN EN 60584-1:1996-10 -200 to +1372 °C 0.4 % 100 ppm/K
Pt10Rh-Pt "S" DIN EN 60584-1:1996-10 -50 to +1768 °C 0.4 % 100 ppm/K
Pt13Rh-Pt "R" DIN EN 60584-1:1996-10 -50 to +1768 °C 0.4 % 100 ppm/K
Pt30Rh-Pt6Rh "B" DIN EN 60584-1:1996-10 0 to 1820 °C 0.4 %
2
100 ppm/K
NiCrSi-NiSi "N" DIN EN 60584-1:1996-10 -100 to 1300 °C 0.4 %
2
100 ppm/K
W3Re-W25Re "D" ASTM E1751M-09 (up to 2315 °C): 2009 0 to 2495 °C 0.4 % 100 ppm/K
W5Re-W26Re "C" ASTM E230M-11: 2011 0 to 2315 °C 0.4 % 100 ppm/K
Cold junction Pt100 internal
Cold junction accuracy ±1 K
Sampling rate 210 ms
Error tolerance time 5 s: time taken into account for all diagnostic tests
Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100 s
1. The accuracy refers to the maximum measuring range.
Measuring range Accuracy Ambient temperature influence
4 to 20 mA, voltage drop < 2 V 0.2 % 150 ppm/K
Scaling Can be freely programmed within the limits
Sampling rate 210 ms
Error tolerance time 5 s: time taken into account for all diagnostic tests
Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100 s
Special features Individual probe 4 to 20 mA
Signal type
Accuracy Residual ripple Load influence Temperature influence Load resistance
Current 4 to 20 mA
0.5 % ±0.5 % at 300 Ω ±0.05 mA/100 Ω 150 ppm/K 500 Ω
0to 20mA
Voltage 2 to 10 V
0.5 % ± 0.5 % ±15 mV 150 ppm/K 500 Ω
0to 10V