Data Sheet 702030 Page 10/12
Display and control elements
Electrical isolation
Connection diagram
The connection diagram in the data sheet provides preliminary information about the connection possibilities. For the electrical connection only
use the brief instructions or the operating manual. The knowledge and the correct technical execution of the safety information/instructions con-
tained in these documents are mandatory for installation, electrical connection, and startup as well as for safety during operation.
The terminal strips on the device rear are equipped with screw terminals. Please refer to the technical data for specifications concerning the con-
ductor cross section.
(A) Programming / one level deeper
(B) Value reduction / previous parameter
(C) Value increase / next parameter
(D) Function key / leave level
(E) Red 7-segment display (factory-set: actual value);
4-digit, configurable decimal place (automatic adjustment on display over-
flow)
(F) Green 7-segment display (factory-set: setpoint value); 4-digit, configurable
decimal place; also display of level and parameter symbols
(G) LED 1 to 3(5): switching position of binary output (LED is lit = output active)
(H) LED ramp function or firing curve
The software version is displayed on the device when
simultaneously pressing keys (A) and (C).
(1) Analog input
(2) Binary input
(3) Setup interface (USB)
(4) Voltage supply
(5) RS485 interface
(6) Analog output
(7) Relay outputs
(8) Logic outputs
LC100 LC200 LC300
(H)
(G)
(E)
(F)
(A)
(B) (C) (D)
(4)
(3) (2) (1)
(7)
(6)(5) (8)
30 V AC
50 V DC
2300 V
AC
30 V AC
50 V DC
2300 V
AC
13
14
76
12
11
10
9
8
N(L-)
5
L1(L+)
4
USB
N(L-)
L1(L+)
5
11
10
4
7
8
9
14
15
16
17
18
19
13
12
USB