JUMO diraTRON 104/108/116/132
Compact controller
Brief description
The controller series comprises five freely configurable, universally usable compact controllers
in various DIN formats to control temperature, pressure, and other process variables.
The devices are characterized by a simple, clearly structured operation supported with texts.
Process values and parameters are represented by two 18-segment LCD displays. The types
702112, 702113 and 702114 are additionally equipped with a pixel matrix LCD display for dis-
playing text. In addition, all devices have individual display elements for the switch positions of
the outputs as well as for manual mode, ramp function, and timer. The devices are operated us-
ing a membrane keyboard with four buttons and can be used under harsh environmental influ-
ences thanks to the high IP65 protection type.
Depending on the hardware design, the devices can be used as two-state controllers, three-state
controllers, three-step controllers, or continuous controllers. The basic type includes autotuning,
a ramp function, a program controller, manual mode, limit value monitoring functions, digital con-
trol signals, extensive timer functions, and a service counter. A math and logic function is also
available as an option. Furthermore, the user has the option to create his/her own application
using structured text (ST code).
The devices can be conveniently configured using a PC with the help of the setup program (incl.
program editor and ST editor). No separate voltage supply is required when configuring via the
USB interface (USB-powered).
diraTRON 104 / type 702114
Block diagram
Analog input (universal)
Digital input
(for potential-free contact)
or
Digital output (logic output 0/14 V)
Setup interface
(USB powered)
Relay (N/O)
Option 2
- Relay ( )
- Logic output 0/14 V
- Analog output 0(2) to 10 V /
0(4) to 20 mA
N/O
Option 1
- Relay (N/O)
- Logic output 0/14 V
- RS485 interface
(only appl. for 702111)
(
)
only applies
for 702111 to 702114
702110
702111
702112
702113
702114
Digital input
()for potential-free contact
Voltage supply
- AC 110 to 240 V or
- AC/DC 20 to 30 V
Relay (N/O)
(only applies for 702111 to 702114)
Option 3
(only applies for 702112 to 702114)
- Relay ( )
- 0/14 V
- PhotoMOS relay
®
N/O
Logic output
Option 4
(only applies for 702112 to 702114)
- Relay ( )
- 0/14 V
- PhotoMOS relay
®
N/O
Logic output
Special features
Fixed-setpoint controller or program con-
troller
2 parameter blocks
Autotuning
Setpoint changeover (4 setpoint values)
Ramp function
Timer function
4 limit value monitoring functions
Service counter
Individual user level
Own application using structured text (ST
code; option)
Math and logic function (option)
Fast wiring through Push-In technology
RS485 interface (option)
Additional analog and digital inputs via
RS485 interface
Approvals/approval marks (see "Technical data")