Datasheet

V2.00/EN/00710338/2019-11-07
Page 13/24Data Sheet 706521
-802*PE+&R.*
'HOLYHU\DGGUHVV 0DFNHQURGWVWUDH
)XOGD*HUPDQ\
3RVWDODGGUHVV
)XOGD*HUPDQ\
3KRQH 
)D[ 
(PDLO PDLO#MXPRQHW
,QWHUQHW ZZZMXPRQHW
-802,QVWUXPHQW&R/WG
-802+RXVH
7HPSOH%DQN5LYHUZD\
+DUORZ(VVH[&0'<8.
3KRQH 
)D[ 
(PDLO VDOHV#MXPRFRXN
,QWHUQHW ZZZMXPRFRXN
-8023URFHVV&RQWURO,QF
0\HUV5RDG
(DVW6\UDFXVH1<86$
3KRQH 
)D[ 
(PDLO LQIRXV#MXPRQHW
,QWHUQHW ZZZMXPRXVDFRP
70652100T10Z001K000
Environmental influences
Case
Approvals and approval marks
Ambient temperature range
Storage -20 to +60 °C
Operation -20 to +50 °C
a
; in conjunction with extra code 970: 0 to 40 °C
a
At temperatures below 0 °C, the build-up of screen contents slows down.
Site altitude Max. 2000 m above sea level
Climatic environmental influences According to DIN EN 60721-3 with extended temperature range
Resistance to climatic
conditions
85 % rel. humidity without condensation
Storage According to class 1K2
Operation According to class 3K3
Mechanical environmental influences According to DIN EN 60721-3
Storage According to class 1M2
Transport According to class 2M2
Operation According to class 3M3
Electromagnetic compatibility (EMC) According to DIN EN 61326-1
Interference emission Class A only for industrial use –
Interference immunity Industrial requirements
Case type Flush-mounted housing according to DIN IEC 61554 made of zinc-plated steel sheet (indoor use)
Case front Made of die-cast zinc with decor foil
Front frame dimensions 144 mm x 144 mm (front frame depth approx. 8 mm including seal)
Mounting depth 120.9 mm (incl. spring-cage terminals)
Panel cut-out 138
+1.0
mm × 138
+1.0
mm
Panel thickness 2 to 8 mm
Case fastening In panel using the four supplied mounting elements
Operating position Any, with due consideration for the viewing angle of the screen,
horizontal ±50°, vertical ±30°
Protection type According to DIN EN 60529, front IP65, back IP20;
in conjunction with extra code 970: IP20 with open carrying case, IP20D with closed carrying case
Weight Max. 1.65 kg (without terminal cover)
Approval mark Testing facility Certificate/certification num-
ber
Inspection basis Valid for
c UL us Underwriters
Laboratories
Submitted UL 61010-1 (3. Ed.),
CAN/CSA-22.2 No. 61010-1
(3rd Ed.)
All versions of the built-in de-
vice; not in conjunction with ex-
tra code 970