70652100T10Z001K000
Order details
(1) Basic type
706521 Paperless recorder with the following interfaces: 1x Ethernet, 2x USB (1x host, 1x device), 1x RS232/485
interface, as well as a relay (changeover contact)
(2) Basic type extension
0 Without software package
1 With software package (setup program incl. USB cable, PC Evaluation Software PCA3000, PCA Communi-
cation Software PCC; in conjunction with extra code "888" as well with PC Security Manager PCS and PC
Audit Trail Manager PCAT software)
(3) Language
8 Default setting (German/English)
9 Set according to customer specifications
(4) Option 1 (slot 1)
a
a
Subsequent expansion is only possible in JUMO Central Services.
0 Not used
1 Analog/digital: 3 analog and 6 digital inputs, 1 analog output
(5) Option 2 (slot 2)
a
0 Not used
1 Analog/digital: 3 analog and 6 digital inputs, 1 analog output
(6) Option 3 (slot 3)
a
0 Not used
4 Digital: 12 digital inputs/outputs (individually switchable)
(7) Voltage supply
23 AC110to240V +10/-15%, 48to63Hz
25 AC/DC20to30V, 48to63Hz
(8) Extra code 1
. Not used
260 Math and logic module (20 channels each)
221 Structured text (ST code)
(9) Extra code 2
. Not used
887 Manipulation detection with digital certificate
888 FDA 21 CFR Part 11 with digital certificate
(10) Extra code 3
. Not used
163 PROFINET IO device interface (incl. Ethernet)
879 AMS2750/CQI-9
b
b
For the calibration certificate it is necessary to state the channels along with the thermocouple type and the desired measuring
points.
(11) Extra code, housing
. Not used
970 Universal carrying case, compact
c
c
The extra code is only available in conjunction with voltage supply AC 110 to 240 V. The UL approval does not apply. Use only
for personnel with technical qualifications who have been specially trained, and have the relevant knowledge in the field of au-
tomation technology! Specifications for ambient temperature and for protection type are to be observed (see technical data)!
(1) (2) (3) (4) (5) (6) (7) (8)
a
a
Multiple selection at positions 8 and 10 is possible. Specify extra codes one after the other, and separate them with com-
mas.
(9) (10)
a
(11)
Order code / - -/,,,
Order example 706521 / 1 8 - 1 1 4 - 23 / 260 , 887 , 163 , 970