Software PCC (B 70.9702.0) Manual

5 Device Management
32
TCP/IP PORT
(ICPDAS
7188E1-8)
The following parameters must be selected.
TCP/IP PORT
(W&T)
The following parameters must be selected.
IP address /
HOST name
xxx.xxx.xxx.xxx
(Example: 192.168.0.10)
Specify the IP address
or the host name of your
device. (If the host name
is used, the IP address
can be determined for
verification by clicking
"Convert host name to
IP address".)
Serial port COM1, COM2, ... Serial port of the
converter to which the
device is connected.
Transmission rate
(baud rate)
9600, 19200, 38400 Transmission rate
between converter and
device. It must match
the rate set in the
device.
Control signal None If the RS232 interface
on the device is used.
RTS permanent
RTS changing
IP address /
HOST name
xxx.xxx.xxx.xxx
(Example: 192.168.0.10)
Specify the IP address
or the host name of your
device. (If the host name
is used, the IP address
can be determined for
verification by clicking
"Convert host name to
IP address".)
Serial port A, B, C, D Serial port of the
converter to which the
device is connected.
Transmission rate
(baud rate)
300, 600, 1200, 2400,
4800, 9600, 14400,
19200, 38400, 57600
Transmission rate
between converter and
device. It must match
the rate set in the
device.