Quick Start Guide

Campus Connectivity MP Quick Start Guide
15
Trapeze Networks
If the external-antenna command is used for the MP-632 it is ignored at the CLI.
If the ANT-5007-OUT antenna is in use on the 11a/n radio then the radio configuration reverts to
2 x 3 mode rather than 3 x 3 mode and the middle port for the radio must not be used.
Ethernet
The MP-632 supports a single IEEE 802.3-compliant auto-sensing 10/100/1000 BaseT Ethernet
interface on the Ethernet input connector. The MP is configured as auto MDI/MDIX and is powered
from the XPS-6201-OUT or XPS-6202-OUT power supplies.
The MP-632 receives separate primary 48VDC power input and Ethernet signal from separate
48VDC and Ethernet input connectors.
The MP-632 48VDC / Ethernet inputs provides primary and secondary lightning protection on all
conductors. (The 48VDC / Ethernet inputs to the MP-632 need lightning protection because the power
supply can be up to 100m (328 ft)away.)
The Ethernet interface supports a cable length of at least 100m over CAT5, CAT5e, or CAT6 cable.
W arning!
The MP-632 must only be used with a Trapeze-approved XPS-6201-OUT or
XPS-6202-OUT power supply in order to prevent possible damage to the unit.
W arning!
Always add the waterproof cap to the RJ45 cable when installing the DIN-RJ45 dongle.
Water can cause damage to the unit and the cables.
W arning!
If you convert the 8 pin female circular DIN data port on the MP-632 bulkhead to a
standard RJ45 waterproof connection for the 10/100/1000 data port, PoE on the
10/100/1000 port must be disabled to prevent service interruption.The MP-632 does not
support PoE on the 10/100/1000 Ethernet data port.