J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Release 8.4 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.
This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright © 1986-1997, Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain. This product includes memory allocation software developed by Mark Moraes, copyright © 1988, 1989, 1993, University of Toronto.
End User License Agreement READ THIS END USER LICENSE AGREEMENT (“AGREEMENT”) BEFORE DOWNLOADING, INSTALLING, OR USING THE SOFTWARE. BY DOWNLOADING, INSTALLING, OR USING THE SOFTWARE OR OTHERWISE EXPRESSING YOUR AGREEMENT TO THE TERMS CONTAINED HEREIN, YOU (AS CUSTOMER OR IF YOU ARE NOT THE CUSTOMER, AS A REPRESENTATIVE/AGENT AUTHORIZED TO BIND THE CUSTOMER) CONSENT TO BE BOUND BY THIS AGREEMENT.
7. Ownership. Juniper and Juniper's licensors, respectively, retain ownership of all right, title, and interest (including copyright) in and to the Software, associated documentation, and all copies of the Software. Nothing in this Agreement constitutes a transfer or conveyance of any right, title, or interest in the Software or associated documentation, or a sale of the Software, associated documentation, or copies of the Software. 8. Warranty, Limitation of Liability, Disclaimer of Warranty.
Abbreviated Table of Contents About This Guide Part 1 J-series Overview Chapter 1 Chapter 2 Chapter 3 Chapter 4 Part 2 Overview of Services Routers System Overview PIM and VoIP Module Overview Services Router User Interface Overview 3 13 43 79 Installing a Services Router Chapter 5 Chapter 6 Chapter 7 Chapter 8 Chapter 9 Part 3 Preparing for Router Installation Installing and Connecting a Services Router Establishing Basic Connectivity Configuring Secure Web Access Installing and Managing J-series L
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide vi ■
Table of Contents About This Guide xv Objectives ......................................................................................................xv Audience .......................................................................................................xv How to Use This Guide .................................................................................xvi Document Conventions ...............................................................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J2320 Power System ...............................................................................24 J2350 Power System ...............................................................................24 J2320 and J2350 Cooling System ............................................................25 J4350 and J6350 Services Router Hardware Features ....................................26 J4350 and J6350 Chassis .................................
Table of Contents TIM514 Analog Telephony Interface Module ...........................................74 TIM521 BRI Telephony Interface Module ................................................75 Chapter 4 Services Router User Interface Overview 79 User Interface Overview ................................................................................79 J-Web Overview ......................................................................................79 CLI Overview .....................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Power Guidelines, Requirements, and Specifications ...................................105 Site Electrical Wiring Guidelines ............................................................106 Signaling Limitations ......................................................................106 Radio Frequency Interference ........................................................106 Electromagnetic Compatibility .......................................
Table of Contents Configuring Basic Settings with a Configuration Editor ................................145 Verifying Basic Connectivity ........................................................................148 Displaying Basic Connectivity Configurations .......................................149 Chapter 8 Configuring Secure Web Access 151 Secure Web Access Terms ...........................................................................151 Secure Web Access Overview ................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Replacing PIM Cables ..................................................................................177 Removing PIM Cables ...........................................................................177 Installing PIM Cables .............................................................................177 Removing and Replacing the Chassis Cover on J2320 and J2350 Routers ....
Table of Contents Part 4 J-series Requirements and Specifications Chapter 13 Network Cable Specifications and Connector Pinouts 225 Serial PIM Cable Specifications ....................................................................225 RS-232 DTE Cable Pinout ......................................................................226 RS-232 DCE Cable Pinout .....................................................................227 RS-422/449 (EIA-449) DTE Cable Pinout .....................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Multiple Power Supplies Disconnection Warning ............................259 Power Disconnection Warning .......................................................260 TN Power Warning .........................................................................261 Telecommunication Line Cord Warning .........................................262 Installation Safety Guidelines and Warnings .........................................
About This Guide This preface provides the following guidelines for using the J2320, J2350, J4350, and J6350 Services Router Getting Started Guide: ■ Objectives on page xv ■ Audience on page xv ■ How to Use This Guide on page xvi ■ Document Conventions on page xvii ■ Related Juniper Networks Documentation on page xviii ■ Documentation Feedback on page xxi ■ Requesting Support on page xxi Objectives This guide contains an overview, basic instructions, and specifications for J2320, J2350, J4350,
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Network administrators who install, configure, and manage Internet routers but are unfamiliar with the JUNOS software ■ Network administrators who install, configure, and manage products of Juniper Networks Personnel operating the equipment must be trained and competent; must not conduct themselves in a careless, willfully negligent, or hostile manner; and must abide by the instructions provided by the documentation.
About This Guide For many J-series features, you can use J-Web Quick Configuration pages to configure the router quickly and easily without configuring each statement individually. For more extensive configuration, use the J-Web configuration editor or CLI configuration mode commands. To monitor, diagnose, and manage a router, use the J-Web interface or CLI operational mode commands. Document Conventions Table 2 on page xvii defines the notice icons used in this guide.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 3: Text and Syntax Conventions (continued) Convention Description Examples Italic sans serif typeface Represents variables (options for which you substitute a value) in commands or configuration statements. Configure the machine’s domain name: Represents names of configuration statements, commands, files, and directories; IP addresses; configuration hierarchy levels; or labels on routing platform components.
About This Guide documentation of the statements and commands described in J-series guides, see the JUNOS software manuals listed in Table 4 on page xix.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 4: J-series Guides and Related JUNOS Software Publications (continued) Chapter in a J-series Guide Corresponding JUNOS Software Manual “Multiprotocol Label Switching Overview” ■ JUNOS MPLS Applications Configuration Guide ■ JUNOS Routing Protocols and Policies Command Reference ■ JUNOS VPNs Configuration Guide ■ JUNOS System Basics Configuration Guide ■ JUNOS Services Interfaces Configuration Guide ■ JUNOS System Basic
About This Guide Table 4: J-series Guides and Related JUNOS Software Publications (continued) Chapter in a J-series Guide Corresponding JUNOS Software Manual “Monitoring the Router and Routing Operations” ■ JUNOS System Basics and Services Command Reference ■ JUNOS Interfaces Command Reference ■ JUNOS Routing Protocols and Policies Command Reference ■ JUNOS System Log Messages Reference ■ Secure Configuration Guide for Common Criteria and JUNOS-FIPS “Monitoring Events and Managing System Log F
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide xxii ■ Requesting Support
Part 1 J-series Overview ■ Overview of Services Routers on page 3 ■ System Overview on page 13 ■ PIM and VoIP Module Overview on page 43 ■ Services Router User Interface Overview on page 79 J-series Overview ■ 1
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 2 ■ J-series Overview
Chapter 1 Overview of Services Routers J-series Services Routers provide stable, reliable, and efficient IP routing, WAN and LAN connectivity, and management services for small to medium-sized enterprise networks. Services Routers typically connect small, branch, or regional offices to a central site router, and link Internet service provider (ISP) networks. All J-series Services Routers run the JUNOS Internet software, which offers many advanced routing and security services.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J2320 Services Router Overview The J2320 Services Router is primarily designed for remote or branch offices. It has a small chassis that is 1 U (rack unit) in size with a nonredundant AC power supply, an external compact flash and two universal serial bus (USB) ports for external storage, and an optional Crypto Accelerator Module.
Chapter 1: Overview of Services Routers upgraded to 1 GB. For instructions on upgrading memory, see “Replacing DRAM Modules” on page 190. Each J2350 chassis contains four built-in Gigabit Ethernet ports with link speeds of 10/100/1000 Mbps over a copper interface. The chassis also contains five slots for field-replaceable Physical Interface Modules (PIMs) and Avaya VoIP modules providing flexible WAN and voice connectivity options.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Gigabit Ethernet uPIM (1-port, 6-port, 8-port, and 16-port) ■ SFP Gigabit Ethernet ePIM (1 port) ■ Copper Gigabit Ethernet ePIM (1 port) ■ Dual-Port Serial PIM ■ Dual-Port E1 PIM ■ Dual-Port T1 PIM ■ Dual-Port Channelized T1/E1/ISDN PRI PIM ■ E3 PIM (1 port) ■ DS3 (T3) PIM (1 port) ■ Dual-Port Fast Ethernet PIM ■ 4-port Fast Ethernet ePIM ■ 4-port ISDN BRI S/T or U PIM ■ ADSL 2/2+ Annex A PIM (1 port) ■ ADSL 2
Chapter 1: Overview of Services Routers ■ Copper Gigabit Ethernet ePIM (1 port) ■ ADSL 2/2+ Annex A PIM (1 port) ■ ADSL 2/2+ Annex B PIM (1 port) ■ Dual-Port E1 PIM ■ E3 PIM (1 port) ■ DS3 (T3) PIM (1 port) ■ Dual-Port Fast Ethernet PIM ■ Dual-Port Channelized T1/E1/ISDN PRI PIM ■ 4-port Fast Ethernet ePIM ■ G.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 5: Summary of J-series Features and License Requirements (continued) Feature Category J-series Feature Routing and Multicast Open Shortest Path First (OSPF) Border Gateway Protocol (BGP) Routing Information Protocol version 1 (RIPv1) and RIPv2 Static routes Intermediate System-to-Intermediate System (IS-IS) Connectionless Network Services (CLNS): ■ End system-to-Intermediate system (ES-IS) protocol ■ IS-IS extensions ■ BGP
Chapter 1: Overview of Services Routers Table 5: Summary of J-series Features and License Requirements (continued) Feature Category J-series Feature Encapsulation Ethernet: Separate License ■ Media access control (MAC) encapsulation ■ 802.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 5: Summary of J-series Features and License Requirements (continued) Feature Category J-series Feature Security Common Criteria Separate License Network attack detection Denial-of-service (DoS) and distributed DoS protection Generic routing encapsulation (GRE), IP-over-IP, and IP Security (IPSec) tunnels Advanced Encryption Standard (AES) 128-, 192-, and 256-bit.
Chapter 1: Overview of Services Routers Table 5: Summary of J-series Features and License Requirements (continued) Feature Category J-series Feature Activity Logging and Monitoring System log Separate License J-Web event viewer Traceroute Administration Supports the following external administrator databases: ■ RADIUS ■ TACACS+ Autoinstallation Configuration rollback Button-operated configuration rescue (CONFIG) Confirmation of configuration changes Software upgrades Supports the following featur
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 12 ■ J-series Software Features and Licenses
Chapter 2 System Overview J-series J2320, J2350, J4350, and J6350 Services Routers have chassis that are similar but with important differences. J2320, J2350, and J4350 routers have a single nonredundant power supply and an optional Crypto Accelerator Module. J6350 routers have redundant power supplies and a standard Crypto Accelerator Module. For field-replaceable PIMs and Avaya VoIP modules, the J2320 has three slots, the J2350 has five slots, and the J4350 and J6350 have six slots.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J2320 and J2350 Chassis The J2320 and J2350 chassis is a rigid sheet metal structure that houses all the other router components (see Figure 1 on page 14 through Figure 7 on page 17). The chassis can be installed in many types of racks or cabinets. For information about acceptable rack types, see “Rack Requirements” on page 102.
Chapter 2: System Overview Figure 2: Front of J2350 Chassis Figure 3: Rear of J2320 Chassis Figure 4: Rear of J2350 AC-Powered Chassis J2320 and J2350 Services Router Hardware Features ■ 15
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 5: Rear of J2350 DC-Powered Chassis Figure 6: J2320 Hardware Components 16 ■ J2320 and J2350 Services Router Hardware Features
Chapter 2: System Overview Figure 7: J2350 Hardware Components Table 6 on page 17 summarizes the physical specifications for the router chassis. Table 6: J2320 and J2350 Physical Specifications Description Value Chassis dimensions ■ ■ Router weight ■ ■ J2320 Services Router ■ 1.75 in. (4.45 cm) high ■ 17.51 in. (44.48 cm) wide—18.9 in. (48.01 cm) wide with mounting brackets attached ■ 15.1 in. (38.35 cm) deep—plus 0.78 in. (1.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J2320 and J2350 Midplane The J2320 and J2350 midplane is located in the center of the chassis and forms the rear of the PIM card cage (see Figure 6 on page 16 and Figure 7 on page 17). You install the PIMs into the midplane from the front of the chassis. Data packets are transferred across the midplane from the PIM to the Routing Engine, and from the Routing Engine across the midplane to the destination PIM.
Chapter 2: System Overview J2320 and J2350 Boot Devices J2320 and J2350 Services Routers can boot from three devices: ■ Internal compact flash ■ External compact flash (also known as the removable compact flash) ■ USB storage device Normally, a J2320 or J2350 Services Router boots from the internal compact flash. If the internal compact flash fails, the router attempts to boot from the external compact flash if it is installed.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ STATUS LED on page 21 ■ ALARM LED on page 21 ■ HA LED on page 22 ■ RESET CONFIG Button on page 22 ■ Built-In Gigabit Ethernet Ports on page 23 ■ Console Port on page 23 ■ AUX Port on page 23 ■ USB Port on page 24 Physical Interface Modules (PIMs) Physical Interface Modules (PIMs) provide the physical connection to various network media types. For information about individual PIMs, see “Field-Replaceable PIMs” on page 46.
Chapter 2: System Overview Table 7: J2320 and J2350 POWER LED Color State Description Green On steadily Power is functioning correctly. Blinking Power button has been pressed and quickly released, and the router is gracefully shutting down. Off Router is not receiving power. Unlit After the router is powered on, status indicators—such as LEDs on the front panel and show chassis command output—can take up to 60 seconds to indicate that the power supply is functioning normally.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 9: J2320 and J2350 ALARM LED Color State Description Red On steadily Major alarm indicates a critical situation on the router that has resulted from one of the following conditions. A red alarm condition requires immediate action: Yellow Unlit On steadily Off ■ One or more hardware components have failed. ■ One or more hardware components have exceeded temperature thresholds.
Chapter 2: System Overview You can change the default behavior of the RESET CONFIG button. For more information, see the J-series Services Router Basic LAN and WAN Access Configuration Guide. Built-In Gigabit Ethernet Ports Four built-in Gigabit Ethernet ports provide LAN connections over copper interfaces to hubs, switches, local servers, and workstations. You can also designate an Ethernet port for management traffic.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide USB Port The USB ports on the front panel of the router (see Figure 8 on page 19 and Figure 9 on page 19) accept a USB storage device or USB storage device adapter with a compact flash installed, as defined in the CompactFlash Specification published by the CompactFlash Association. When a USB storage device is installed and configured, it automatically acts as a secondary boot device if the internal compact flash fails on startup.
Chapter 2: System Overview The AC power supply has a single AC appliance inlet that requires a dedicated AC power feed. The DC power supply has a terminal block that provides a single DC input (–48 VDC and return) and requires a dedicated 15 A (–48 VDC) circuit breaker. The J2350 AC-powered or DC-powered chassis has a power switch and does not include a power LED. For information about site power preparations, see “Power Guidelines, Requirements, and Specifications” on page 105.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 11: Airflow Through the J2320 Chassis Figure 12: Airflow Through the J2350 Chassis J4350 and J6350 Services Router Hardware Features This section contains the following topics: 26 ■ ■ J4350 and J6350 Chassis on page 27 ■ J4350 and J6350 Midplane on page 31 ■ J4350 and J6350 Routing Engine Hardware on page 31 ■ J4350 and J6350 Boot Devices on page 31 ■ J4350 and J6350 Front Panel on page 32 J4350 and J6350 Services Ro
Chapter 2: System Overview ■ J4350 Power System on page 36 ■ J6350 Power System on page 37 ■ J4350 and J6350 Cooling System on page 38 J4350 and J6350 Chassis The J4350 and J6350 chassis is a rigid sheet metal structure that houses all the other router components (see Figure 13 on page 28 through Figure 18 on page 30). The chassis can be installed in many types of racks or cabinets. For information about acceptable rack types, see “Rack Requirements” on page 102.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 13: Front of J4350 and J6350 Chassis Figure 14: Rear of J4350 AC-Powered Chassis NOTE: The J4350 AC-powered chassis has a power switch and does not include a power supply LED (unlike the J6350 AC-powered chassis).
Chapter 2: System Overview Figure 16: Rear of J4350 DC-Powered Chassis Figure 17: Rear of DC-Powered J6350 Chassis J4350 and J6350 Services Router Hardware Features ■ 29
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 18: J4350 and J6350 Hardware Components Table 11 on page 30 summarizes the physical specifications for the router chassis. Table 11: J4350 and J6350 Physical Specifications Description Value Chassis dimensions ■ 3.44 in. (8.74 cm) high ■ 17.44 in. (44.3 cm) wide—19.44 in. (48.38 cm) wide with mounting brackets attached ■ 21.13 in. (53.67 cm) deep—plus 0.5 in. (1.
Chapter 2: System Overview J4350 and J6350 Midplane The midplane is located in the center of the chassis and forms the rear of the PIM card cage (see Figure 18 on page 30). You install the PIMs into the midplane from the front of the chassis. Data packets are transferred across the midplane from the PIM to the Routing Engine, and from the Routing Engine across the midplane to the destination PIM. J4350 and J6350 Routing Engine Hardware The Routing Engine consists of the following components.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J4350 and J6350 Front Panel The front panel of the Services Router (see Figure 19 on page 32) allows you to install or remove PIMs, view router status LEDs, access the console port, and perform simple control functions.
Chapter 2: System Overview Each J4350 and J6350 Services Router has six front panel slots for field-replaceable PIMs. These slots are numbered from top to bottom and from left to right as shown in the slot number diagram on the front panel, shown in Figure 20 on page 33. Figure 20: Slot Number Diagram on Front Panel Gigabit Ethernet and 4-port Fast Ethernet ePIMs can be installed in high-speed slots only.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide STATUS LED When the system is powered on, the STATUS LED changes from off to blinking green. Startup takes approximately 90 seconds to complete. If you want to turn the system off and on again, we recommend waiting a few seconds between shutting it down and powering it back up. Table 13 on page 34 describes the STATUS LED. Table 13: STATUS LED Color State Description Green Blinking Router is starting up or performing diagnostics.
Chapter 2: System Overview HA LED The HA (high availability) LED is for future use. The LED lights when the router starts, but otherwise remains unlit. RESET CONFIG Button Use the RESET CONFIG button to return the router to either the rescue configuration or the factory default configuration. The button is recessed to prevent it from being pressed accidentally. To press this button insert a small probe (such as a straightened paper clip) into the pinhole on the front panel (see Figure 19 on page 32).
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 15: Gigabit Ethernet Port LEDs (continued) Function Color State Description TX/RX Green Blinking Port is transmitting or receiving data. Unlit Off Port might be online, but it is not receiving data. Console Port You can use the console port on the chassis front panel to connect to the Routing Engine through an RJ-45 serial cable. From the chassis console port, you can use the CLI to configure the router.
Chapter 2: System Overview The J4350 AC-powered chassis has a power switch and does not include a power LED. The J4350 DC-powered chassis includes a power supply LED located to the upper right of the power supply connector. Table 16 on page 37 describes the power supply LED. Table 16: Power Supply LED State Description Off No power is flowing to the power supply. Green Power supply is connected and power is flowing. Yellow Power supply is connected, but the router is not powered on.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Power supplies on J6350 Services Routers are hot-removable and hot-insertable. You can remove and replace a redundant power supply without powering down the router or disrupting the routing functions. To avoid electrical injury, carefully follow the instructions in “Replacing Power System Components” on page 193. NOTE: You cannot mix DC and AC power supplies in the same chassis.
Chapter 2: System Overview Figure 21: Airflow Through the J4350 and J6350 Chassis Software Overview Each J-series Services Router runs the JUNOS Internet software on its general-purpose processors. Designed for the large production networks typically supported by Internet service providers (ISPs), the JUNOS software includes processes for Internet Protocol (IP) routing and for managing interfaces, networks, and the router chassis. The JUNOS Internet software runs on the Routing Engine.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Routing Engine and Packet Forwarding Engine A Services Router has two primary software processing components: ■ ■ Routing Engine—The Routing Engine provides three main functions: ■ Creates the packet forwarding switch fabric for the Services Router, providing route lookup, filtering, and switching on incoming data packets, then directing outbound packets to the appropriate interface for transmission to the network.
Chapter 2: System Overview Table 17: JUNOS Software Processes Process Name Description Management process mgd Manages the Services Router system as follows: Chassis process chassisd ■ Provides communication between the other processes and an interface to the configuration database ■ Populates the configuration database with configuration information and retrieves the information when queried by other processes to ensure that the system operates as configured ■ Interacts with the other processe
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide For more information, see “Services Router User Interface Overview” on page 79. Other user interfaces for the Services Router interact with the management process through the common API interface. These interfaces are designed to facilitate the configuration of one or, in some cases, many routers on the network. Among the supported interfaces are the JUNOScope and Session and Resource Control (SRC) applications.
Chapter 3 PIM and VoIP Module Overview J-series Services Routers accept Physical Interface Modules (PIMs) and Avaya VoIP modules in the slots on the front of the chassis. CAUTION: PIMs and VoIP modules are not hot-swappable. You must power off the Services Router before removing or inserting a PIM or VoIP module. Ensure that the PIMs and VoIP modules are installed in the router chassis before booting up the system.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide PIM and VoIP Module Terms To understand PIMs and VoIP modules, become familiar with the terms defined in Table 18 on page 44. Table 18: PIM and VoIP Module Terms Term Definition ADSL 2/2+ Annex A ITU-T Standard G.992.1 that defines how ADSL works over plain old telephone service (POTS) lines. ADSL 2/2+ Annex B ITU-T Standard G.992.1 that defines how ADSL works over Integrated Services Digital Network (ISDN) lines.
Chapter 3: PIM and VoIP Module Overview Table 18: PIM and VoIP Module Terms (continued) Term Definition dialer filter Stateless firewall filter that enables dial-on-demand routing backup when applied to a physical ISDN interface and its dialer interface configured as a passive static route. The passive static route has a lower priority than dynamic routes.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Field-Replaceable PIMs PIMs are removable and insertable only when the Services Router is powered off. You can install a PIM into one of the slots in the router chassis. If a slot is not occupied by a PIM, a PIM blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
Chapter 3: PIM and VoIP Module Overview NOTE: Although J2320 and J2350 Services Routers support PIMs that were introduced before the JUNOS 8.4 release, these routers do not support software releases earlier than JUNOS 8.4. Table 19: J2320 and J2350 Field-Replaceable PIM Summary Sample Interface Name PIM 1-Port SFP, 6-Port SFP, 8-Port, and 16-Port Gigabit Ethernet uPIMs Supported Software Releases for This PIM Port Numbering (type-pim/0/port) JUNOS 8.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide NOTE: Although J4350 and J6350 Services Routers support PIMs that were introduced before the JUNOS 8.0 release, these routers do not support software releases earlier than JUNOS 8.0. Table 20: J4350 and J6350 Field-Replaceable PIM Summary Sample Interface Name PIM 1-Port SFP Gigabit Ethernet uPIM Supported Software Releases for This PIM Slot and Port Numbering (type-pim/0/port) JUNOS 8.
Chapter 3: PIM and VoIP Module Overview Table 20: J4350 and J6350 Field-Replaceable PIM Summary (continued) Sample Interface Name PIM Supported Software Releases for This PIM Slot and Port Numbering (type-pim/0/port) T3 or E3 PIM JUNOS 8.0 and later Slots—1 through 6 t3-0/0/0 Port—0 or e3-2/0/0 Dual-Port Fast Ethernet PIM JUNOS 8.0 and later Slots—1 through 6 fe-1/0/0 Ports—0 and 1 4-port Fast Ethernet ePIM PIM JUNOS 8.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 22: 1-Port Gigabit Ethernet uPIM Figure 23: 6-Port Gigabit Ethernet uPIM The 8-port and 16-port Gigabit Ethernet uPIMs, shown in Figure 24 on page 50 and Figure 25 on page 50, have RJ-45 connectors.
Chapter 3: PIM and VoIP Module Overview Features. Gigabit Ethernet uPIMs provide the following key features: ■ The multiport uPIMs can be used as switches in the access layer (for connections to workstations and desktops). For more information, see the J-series Services Router Basic LAN and WAN Access Configuration Guide. ■ Link speed for 8-port and 16-port Gigabit Ethernet uPIMs is configurable to 10, 100, or 1000 Mbps, and transmission mode is configurable to half or full duplex.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 21: Gigabit Ethernet Port LEDs Function Color State Description Link Green On steadily Port is online. Unlit Off Port is offline. Green Blinking Port is transmitting or receiving traffic. Unlit Off Port might be online, but it is not receiving traffic. Activity (TX/RX) For alarms, see the configuring and monitoring alarms information in the J-series Services Router Administration Guide. Optical Interface Support.
Chapter 3: PIM and VoIP Module Overview Figure 26: Copper Gigabit Ethernet ePIM Figure 27: SFP Gigabit Ethernet ePIM Features. The Gigabit Ethernet ePIM provides the following key features: ■ Autonegotiation through medium-dependent interface (MDI) and MDI crossover (MDI-X) support. ■ Link speeds for the Copper Gigabit Ethernet ePIM are configurable to 10, 100, or 1000 Mbps, and transmission mode is configurable to half or full duplex.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Limitations. The Gigabit Ethernet ePIM has the following limitations: ■ Gigabit Ethernet ePIMs do not support SNMP. ■ Configure Gigabit Ethernet ePIM interfaces up to a maximum MTU size of 9018 bytes. Installation. You can install Gigabit Ethernet ePIMs in any high-speed slot as follows: ■ J4350—Install up to two Gigabit Ethernet ePIMs in slots 3 and 6. ■ J6350—Install up to four Gigabit Ethernet ePIMs in slots 2, 3, 5, and 6.
Chapter 3: PIM and VoIP Module Overview Table 24: Optical Interface Support for SFP Gigabit Ethernet ePIM (continued) Parameter 1000Base-SX Transceiver 1000Base-LX Transceiver Average launch power –9.5 dBm through –4 dBm For SMF cable: –9.5 dBm through –3 dBm For MMF cable: –11.5 dBm through –3 dBm Receiver saturation –3 dBm –3 dBm Receiver sensitivity –18 dBm –20.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 25: Status LEDs for Serial Ports Color State Description Green On steadily Online with no alarms or failures. Red On steadily Active with a local alarm. The router has detected a failure. Unlit Off Offline. For alarms, see the configuring and monitoring alarms information in the J-series Services Router Administration Guide.
Chapter 3: PIM and VoIP Module Overview ■ G.703, G.704, and G.706 E1 standards compliance ■ Independent internal and external clocking system ■ Loopback, bit error rate test (BERT), T1 facilities data link (FDL), and long buildout diagnostics For pinouts of cable connectors for T1 and E1 PIMs, see “E1 and T1 RJ-48 Cable Pinouts” on page 237. To install or remove a PIM, see “Replacing a PIM” on page 174. Status LEDs indicate port status. Table 26 on page 57 describes the meaning of the LED states.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 31: Channelized T1/E1/ISDN PRI PIM The Dual-Port Channelized T1/E1/ISDN PRI PIM provides the following key features: ■ Onboard network processor ■ Two-port channelization ■ Interfaces that are software configurable as T1 or E1 channels or ISDN PRI B-channels ■ Clear-channel, fractional, and channelized operation ■ Lower latency due to the addition of a Freescale processor ■ Maximum MTU value of 4500 bytes (for channeliz
Chapter 3: PIM and VoIP Module Overview Table 27: LEDs for Channelized T1/E1/ISDN PRI PIMs Label Color State Description ONLINE Green On steadily PIM is online and operational. Unlit Off PIM is not online. Green On steadily Port is online with no alarms or failures, and the physical layer is active. Red Online Port is active with a local alarm. The router has detected a failure and the physical layer is inactive. Yellow Online Port is online with alarms for remote failures.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 33: E3 PIM The T3 and E3 PIMs provide the following key features: ■ Onboard network processor ■ Integrated DSU—Eliminates the need for a separate external device ■ Subrate and scrambling options with support for major DSU vendors ■ Independent internal and external clocking system ■ Loopback (payload–supported only on T3 PIM, local, and remote), bit error rate test (BERT), and T3 far-end alarm and control (FEAC) diagnosti
Chapter 3: PIM and VoIP Module Overview Dual-Port Fast Ethernet PIM The Dual-Port 10/100-Mbps Fast Ethernet PIM (Figure 34 on page 61) has two physical Fast Ethernet ports.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 4-Port Fast Ethernet ePIM You can install 4-Port Fast Ethernet ePIMs in any of the high-speed slots, as follows: ■ J4350—Install up to two 4-Port Fast Ethernet ePIMs in slots 3 and 6. ■ J6350—Install up to four 4-Port Fast Ethernet ePIMs in slots 2, 3, 5, and 6.
Chapter 3: PIM and VoIP Module Overview Table 30: LEDs for 4-Port Fast Ethernet ePIM Label Color State Description Link status (upper left) Green On steadily Port is online. Unlit Off Port is offline. Green Blinking Port is transmitting or receiving data. Unlit Off Port might be online, but it is not transmitting or receiving data. Link activity (upper right) For alarms, see the configuring and monitoring alarms information in the J-series Services Router Administration Guide.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Dial backup ■ Dial-on-demand routing backup (floating static and dialer watch) For pinouts of cable connectors for ISDN PIMs, see “ISDN RJ-45 Connector Pinout” on page 241. To install or remove a PIM, see “Replacing a PIM” on page 174. ISDN LEDs indicate PIM and port status. Table 31 on page 64 describes the meaning of the LED states.
Chapter 3: PIM and VoIP Module Overview Figure 38: ADSL 2/2+ Annex A PIM Figure 39: ADSL 2/2+ Annex B PIM The ADSL PIM provides the following key features: ■ Onboard network processor ■ ADSL, ADSL2, and ADSL2+ protocols on the same PIM ■ “Dying gasp” notification ■ Asynchronous Transfer Mode (ATM) Adaptation Layer 5 (AAL5) encapsulation For pinouts of cable connectors for ADSL PIMs, see “ADSL and G.SHDSL RJ-11 Connector Pinout” on page 240.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide For alarms, see the configuring and monitoring alarms information in the J-series Services Router Administration Guide. G.SHDSL PIM The G.SHDSL PIM (Figure 40 on page 66) provides symmetric high-speed digital subscriber line (SHDSL) physical interfaces to ATM network media types. The G.SHDSL PIM has two ports for ATM-over-SHDSL connections. Figure 40: G.SHDSL PIM The G.
Chapter 3: PIM and VoIP Module Overview Table 33: LEDs for G.SHDSL PIMs Label Color State Description ONLINE Green On steadily Online with no alarms or failures. Red Disconnected Initialization of the PIM has failed. Unlit Off PIM is booting. Green On steadily Online with no alarms or failures. Red On steadily Active with a local alarm. The router has detected a failure.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide CAUTION: Do not install a combination of PIMs in a single chassis that exceeds the maximum power and heat capacity of the chassis. If J-series power management is enabled, PIMs that exceed the maximum power and heat capacity remain offline when the chassis is powered on. On each J-series Services Router with Avaya VoIP, a single TGM550 Telephony Gateway Module (TGM) and at least one telephony interface module (TIM) is required.
Chapter 3: PIM and VoIP Module Overview Table 35: J4350 and J6350 Avaya VoIP Module Summary Sample Interface Name PIM Also Called TGM550 Telephony Gateway Module ■ TGM550 Gateway Module ■ TGM550 TIM510 E1/T1 Telephony Interface Module ■ TIM510 E1/T1 media module ■ TIM510 TIM514 Analog Telephony Interface Module ■ TIM514 analog media module ■ TIM514 TIM521 BRI Telephony Interface Module ■ TIM521 BRI media module ■ TIM521 Software Release for This PIM Slot and Port Numbering Maximum N
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 41: TGM550 Telephony Gateway Module The TGM550 provides the following key features: ■ ■ ■ ■ Voice ■ VoIP Media Gateway services. ■ Two analog telephone (LINE) ports to support two analog telephones or incoming analog direct inward dialing (DID) trunks with either wink start or immediate start. An analog relay supports emergency transfer relay (ETR).
Chapter 3: PIM and VoIP Module Overview Table 36 on page 71 lists the maximum number of media servers, telephones, TIMs, and so on that are supported by the TGM550 installed on a J4350 or J6350 Services Router.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 36: TGM550 Maximum Media Gateway Capacities (continued) Hardware or Feature TGM550 Maximum Capacity Additional Information Digital signal processors (DSPs) 1 (up to 80 channels) The DSP supports 80 channels for calls using voice codec sets with 20-millisecond-or-higher packet sizes. For calls with 10-millisecond-or-lower packet sizes, the DSP supports 40 channels.
Chapter 3: PIM and VoIP Module Overview Table 37: LEDs for TGM550 Gateway Module (continued) Label Color State Description ACT Yellow On steadily Active. The TGM550 is online with network traffic. ASB Green On steadily Alternate software bank. The software is not running from the selected boot bank. ETR Green On steadily Emergency transfer relay (ETR) feature is active.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide TIM510 LEDs indicate link status and activity. Table 38 on page 74 describes the meaning of the LEDs. Table 38: LEDs for TIM510 Label Color State Description ALM Red On steadily Alarm. A TIM510 failure requires monitoring or maintenance. ACT Green On steadily Active. The TIM510 is online with network traffic. TST Yellow On steadily Test. A test is being performed on the TIM510 through the Media Gateway Controller (MGC).
Chapter 3: PIM and VoIP Module Overview Table 39: TIM514 Possible Port Configurations Possible Analog Telephone (LINE) Port Configurations Possible Analog Trunk (TRUNK) Port Configurations Wink-start or immediate-start DID trunk Loop-start or ground-start central office trunk with a loop current of 18 milliamperes (mA) to 120 mA Analog tip/ring devices such as single-line telephones with or without LED message-waiting indication Two-wire analog outgoing centralized automatic message accounting (CAMA)
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide port has two B-channels plus a D-channel. Up to two TIM521s (with 4 BRI trunk ports each) can be installed in any of the slots on the Services Router. Figure 44: TIM521 BRI Telephony Interface Module For ISDN BRI trunking, the TIM521 supports up to four BRI interfaces to the central office at the ISDN T reference point.
Chapter 3: PIM and VoIP Module Overview For more information about the TIM521, see the Avaya manual Hardware Description and Reference for Avaya Communication Manager.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 78 ■ Avaya VoIP Modules
Chapter 4 Services Router User Interface Overview You can use two user interfaces to monitor, configure, troubleshoot, and manage a Services Router—the J-Web interface and the JUNOS command-line interface (CLI).
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Edit the configuration in a text file. ■ Upload a configuration file. The J-Web interface also allows you to manage configuration history and set a rescue configuration. ■ Diagnosing—Diagnose routing problems by running the ping or traceroute diagnostic tool. The diagnostic tools also allow you to capture and analyze control traffic on the routers.
Chapter 4: Services Router User Interface Overview Using the J-Web Interface This section contains the following topics: ■ Starting the J-Web Interface on page 81 ■ J-Web Layout on page 82 ■ Elements of the J-Web Interface on page 83 ■ Navigating the J-Web Interface on page 85 ■ J-Web Sessions on page 88 For more information about using the J-Web interface, see the J-Web Interface User Guide. Starting the J-Web Interface To start the J-Web interface: 1.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide J-Web Layout Each page of the J-Web interface is divided into the following panes, as shown in Figure 45 on page 82. ■ Top pane—Displays identifying information and links. ■ Main pane—Location where you monitor, configure, diagnose, and manage the Services Router by entering information in text boxes, making selections, and clicking buttons.
Chapter 4: Services Router User Interface Overview Elements of the J-Web Interface This section summarizes the elements of the top pane, side pane, and main pane of the J-Web interface. Top Pane Elements The top pane comprises the elements shown in Figure 46 on page 83. Figure 46: Top Pane Elements ■ Juniper Networks logo—Link to http://www.juniper.net in a new browser window. ■ hostname – model—Hostname and model of the Services Router.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Main Pane Elements The main pane comprises the elements shown in Figure 47 on page 84. Figure 47: Main Pane Elements 84 ■ ■ Help (?) icon—Displays useful information when you move the cursor over the question mark. This help displays field-specific information, such as the definition, format, and valid range of the field. ■ Red asterisk (*)—Indicates a required field.
Chapter 4: Services Router User Interface Overview Side Pane Elements The side pane comprises the elements shown in Figure 48 on page 85. Figure 48: Side Pane Elements ■ Subtask—Displays options related to the selected task in the J-Web taskbar. ■ Configuration hierarchy—For the J-Web configuration editor, displays the hierarchy of committed statements in the Services Router configuration. ■ Click Expand all to display the entire hierarchy.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide from all pages, allowing you to skip from one task or subtask to the other from any page in the interface. The path displayed in the top right corner of each page provides a context. Use this path to see your location in a configuration hierarchy. Clicking any link in the path displays the corresponding page. You can easily navigate to most subtasks by selecting them from the side pane.
Chapter 4: Services Router User Interface Overview Table 43: Key J-Web Edit Configuration Buttons Function Button Apply edits to the candidate configuration, and return one level up (previous page) in the configuration hierarchy. OK Clear the entries you have not yet applied to the candidate configuration, and return one level up (previous page) in the configuration hierarchy. Cancel Verify edits and apply them to the current configuration file running on the Services Router.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 49: CoS Help Page J-Web Sessions You establish a J-Web session with the Services Router through an HTTP-enabled or HTTPS-enabled Web browser. The HTTPS protocol, which uses 128-bit encryption, is available only in domestic versions of the JUNOS software. To use HTTPS, you must have installed a certificate on the Services Router and enabled HTTPS.
Chapter 4: Services Router User Interface Overview Using the Command-Line Interface This section contains the following topics: ■ CLI Command Hierarchy on page 89 ■ Starting the CLI on page 90 ■ CLI Operational Mode on page 90 ■ CLI Configuration Mode on page 91 ■ CLI Basics on page 92 For more information about the CLI, see the JUNOS CLI User Guide.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide intervening space), you see a list of commands that match the partial name you typed. Starting the CLI To start the CLI: 1. 2. Establish a connection with the Services Router: ■ To access the router remotely from the network, enter the command you typically use to establish a remote connection (such as Telnet or ssh) using the router hostname.
Chapter 4: Services Router User Interface Overview set show ssh start telnet test traceroute Set CLI properties, date/time, craft interface message Show system information Start secure shell on another host Start shell Telnet to another host Perform diagnostic debugging Trace route to remote host At the top level of operational mode are a number of broad groups of CLI commands that are used to perform the following functions: ■ Control the CLI environment. ■ Monitor and troubleshoot the router.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide insert load quit rename rollback run save set show status top up wildcard Insert a new ordered data element Load configuration from ASCII file Quit from this level Rename a statement Roll back to previous committed configuration Run an operational-mode command Save configuration to ASCII file Set a parameter Show a parameter Show users currently editing configuration Exit to top level of configuration Exit one level of configuration Wild
Chapter 4: Services Router User Interface Overview Table 44: CLI Editing Keystrokes Task Category Action Keyboard Sequence Move the cursor. Move the cursor back one character. Ctrl-b Move the cursor back one word. Esc b Move the cursor forward one character. Ctrl-f Move the cursor forward one word. Esc f Move the cursor to the end of the command line. Ctrl-e Delete the character before the cursor. Ctrl-h, Delete, or Backspace Delete the character at the cursor.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide To complete a command or option that you have partially typed, press Tab or Spacebar. If the partially typed letters uniquely identify a command, the complete command name appears. Otherwise, a message indicates that your entry is ambiguous or invalid. Possible command completions are displayed if your entry is ambiguous. You can also use command completion on filenames and usernames.
Chapter 4: Services Router User Interface Overview When you enter the help commands described in Table 45 on page 95, the CLI displays usage guidelines and summary information for configuration statements and operational mode commands. You can enter help commands in operational or configuration mode. Table 45: help Commands CLI Command Description help apropos string Displays help based on a text string contained in a statement or command name.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide user@host> set cli ? Possible completions: complete-on-space directory idle-timeout prompt restart-on-upgrade screen-length screen-width terminal Set Set Set Set Set whether typing space completes current word working directory maximum idle time before login session ends CLI command prompt string whether CLI prompts to restart after software upgrade Set number of lines on screen Set number of characters on a line Set terminal type Tab
Chapter 4: Services Router User Interface Overview Table 46: Configuring the CLI Environment (continued) Environment Feature CLI Command Default Setting Options Number of CLI characters displayed on a line set cli screen-width width Variable (depends on terminal type). To change the number of characters displayed on a line, replace width with a value between 0 and 100,000. Your terminal type. set cli terminal terminal-type unknown, or set by console.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 98 ■ Using the Command-Line Interface
Part 2 Installing a Services Router ■ Preparing for Router Installation on page 101 ■ Installing and Connecting a Services Router on page 115 ■ Establishing Basic Connectivity on page 129 ■ Configuring Secure Web Access on page 151 ■ Installing and Managing J-series Licenses on page 161 Installing a Services Router ■ 99
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 100 ■ Installing a Services Router
Chapter 5 Preparing for Router Installation Before installing a J-series Services Router, make sure that your site has the proper operating environment and equipment. Use the checklist at the end of the chapter to help you prepare your site.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Rack Requirements J-series Services Routers must be installed in a rack. Many types of racks are acceptable, including front-mount racks, four-post (telco) racks, and center-mount racks.
Chapter 5: Preparing for Router Installation The J2320 chassis height of 1.75 in. (4.45 cm) equals 1 U. The J2350 chassis height of 2.61 in. (6.63 cm) equals 1.5 U. Each U is a standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics Industry Association.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Router Environmental Tolerances Table 47 on page 104 specifies the environmental conditions required for normal Services Router operation. In addition, the site must be as dust-free as possible. Dust can clog air intake vents, reducing cooling system efficiency. Check vents frequently, cleaning them as necessary.
Chapter 5: Preparing for Router Installation Then, use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire. For more information about fire extinguishers, see “Fire Suppression Equipment” on page 105. Fire Suppression Equipment Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide (CO2) and Halotron, are most effective for suppressing electrical fires.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Site Electrical Wiring Guidelines WARNING: DC-powered J2350, J4350, and J6350 Services Routers are intended for installation only in a restricted access location. When planning the electrical wiring at your site, consider the factors discussed in the following sections. Signaling Limitations Improperly installed wires can emit radio interference.
Chapter 5: Preparing for Router Installation Table 48: AC and DC Power System Electrical Specifications for J2320 and J2350 Routers Item Specification AC input voltage 100 to 240 VAC nominal AC input line frequency 50 to 60 Hz AC system current rating J2320 Services Routers: 3.2 A to 1.3 A J2350 Services Routers: 3.5 A to 1.5 A DC input voltage –48 to –60 VDC operating range DC system current rating 7.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 50 on page 108 lists AC power cord specifications provided for each country or region. Table 50: AC Power Cord Specifications Country Electrical Specifications Plug Standards Australia 250 VAC, 10 A, 50 Hz AS/NZ 3112–1993 China 250 VAC, 10 A, 50 Hz GB2099.
Chapter 5: Preparing for Router Installation ■ J2350 routers—minimum 15 A (–48 VDC) ■ J4350 and J6350 routers—minimum 25 A (–48 VDC) If the J6350 router contains redundant DC power supplies, one power supply must be powered by a dedicated power feed derived from feed A, and the other power supply must be powered by a dedicated power feed derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Planning for Power Management Before you install a chassis or add a new PIM to an existing chassis, verify that the combination of PIMs to be installed does not exceed the power and heat capacities for that model. Add the power and heat tokens required by each PIM, and compare them to the capacity of the chassis.
Chapter 5: Preparing for Router Installation Table 51: J-series PIM Power Consumption and Heat Dissipation (continued) Name Model Number PIM Abbreviation in JUNOS CLI Tokens Power Heat Dual-Port E1 PIM JX-2E1-RJ48-S 2xE1 6 6 Dual-Port T1 PIM JX-2T1-RJ48-S 2xT1 6 5 Dual-Port Channelized T1/E1/ISDN PRI PIM JX-2CT1E1-RJ45-S 2xCT1E1 / PRI 6 5 E3 PIM (1 port) JX-1E3-S 1xE3 7 7 T3 PIM (also known as DS3) JX-1DS3-S 1xT3 7 7 Dual-Port Fast Ethernet PIM JX-2FE-TX-S 2xFE 6 6 4-Port
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 52 on page 112 lists the maximum power tokens and maximum heat tokens available for each model. Table 52: Maximum Power and Heat Capacities of J-series Models Model Power Capacity (tokens) Heat Capacity (tokens) J2320 50 50 J2350 83 83 J4350 100 100 J6350 100 100 Network Cable Specifications The Services Router supports interfaces that use various kinds of network cable.
Chapter 5: Preparing for Router Installation Table 53: Site Preparation Checklist (continued) Item or Task Performed By Date Notes Plan the rack location, including required space clearances. Secure the rack to the floor and the building structure. Acquire appropriate cables and connectors.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 114 ■ Site Preparation Checklist
Chapter 6 Installing and Connecting a Services Router Make the appropriate preparations and verify the J-series equipment before installing a J-series Services Router and connecting it to a power source and the network. CAUTION: Do not install a combination of PIMs in a single chassis that exceeds the maximum power and heat capacity of the chassis. If J-series power management is enabled, PIMs that exceed the maximum power and heat capacity remain offline when the chassis is powered on.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ ■ For J2320 and J2350 Routers—Number 2 Phillips screwdriver, and mounting screws appropriate for your rack. ■ For J4350 and J6350 Routers—Mounting brackets and screws (provided), number 2 Phillips screwdriver, and mounting screws appropriate for your rack.
Chapter 6: Installing and Connecting a Services Router Installing J2320 and J2350 Routers WARNING: DC-powered Services Routers are intended for installation only in a restricted access location. You can center-mount or front-mount the J2320 and J2350 Services Routers in a rack. In general, a center-mount rack is preferable to a front-mount rack because the more even distribution of weight in the center-mount rack provides greater stability.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 3. Align the top hole in each mounting bracket with a hole in each rack rail as shown in Figure 53 on page 118 and Figure 54 on page 118, making sure the chassis is level. Figure 53: Hanging a J2320 Router in a Rack Figure 54: Hanging a J2350 Router in a Rack 4. Have a second person install a mounting screw into each of the two aligned holes. With a number 2 Phillips screwdriver, tighten the screws. 5.
Chapter 6: Installing and Connecting a Services Router You can center-mount or front-mount the J4350 and J6350 Services Routers in a rack. In general, a center-mount rack is preferable to a front-mount rack because the more even distribution of weight in the center-mount rack provides greater stability. Many types of racks are acceptable, including four-post (telco) racks, enclosed cabinets, and open-frame racks.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 56: Attaching Center Screw to the Rack 3. Lift the router and insert the larger elliptical openings in the mounting brackets onto the partially inserted screws so that the router is hanging from the two screws (see Figure 57 on page 120). Figure 57: Hanging the Router in the Rack 120 ■ 4.
Chapter 6: Installing and Connecting a Services Router Figure 58: Completing the Installation Connecting Interface Cables to Services Routers You connect the interfaces installed in the Services Router to various network media. For more information about the network interfaces supported on the router, see the J-series Services Router Basic LAN and WAN Access Configuration Guide. 1.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ For J2320 and J2350 Services Routers—The grounding cables must be, at minimum, 14 AWG single-strand wire cable. The grounding lug must be a ring-type, vinyl-insulated TV14-8R lug as shown in Figure 59 on page 123 and Figure 60 on page 124. ■ For J4350 and J6350 Services Routers—The grounding cables must be, at minimum, 12 AWG single-strand wire cable. The grounding lug must be a two-hole lug as shown in Figure 61 on page 124.
Chapter 6: Installing and Connecting a Services Router c. With a Phillips screwdriver, remove the screw and washer from the PEM nuts at the grounding point on the rear of the chassis. d. Place the grounding lug at the other end of the cable over the grounding point, as shown in Figure 59 on page 123 through Figure 61 on page 124. e. Secure the cable lug to the grounding point, first with the washer, then with the screw.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 60: Connecting AC Power to the J2350 Services Router Figure 61: Connecting AC Power to the J4350 or J6350 Services Router Connecting DC Power CAUTION: If your J6350 Services Router includes an optional redundant DC power supply, connect each of the two power supplies to different input power sources. Failure to do so makes the router susceptible to total power failure if one of the power supplies fails.
Chapter 6: Installing and Connecting a Services Router 1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 249. 2. Use a grounding cable to connect the router to earth ground: (For cable requirements, see “Chassis Grounding” on page 121.) a.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide overtighten. Apply between 8 lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torque to the screw. f. Using the other removed screw, secure the negative (–) DC source power cable lug to the –48 VDC terminal. Tighten the screw until snug. Do not overtighten. Apply between 8 lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torque to the screw. g. Dress the power cables appropriately. h. Replace the clear plastic cover over the terminal block. 4.
Chapter 6: Installing and Connecting a Services Router Figure 63: Connecting DC Power to the J4350 or J6350 Services Router Powering a Services Router On and Off To power on a Services Router, press the power button. The Routing Engine boots as the power supply completes its startup sequence. The POWER LED lights during startup and remains on steadily when the router is operating normally.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 128 ■ Powering a Services Router On and Off
Chapter 7 Establishing Basic Connectivity The JUNOS software is preinstalled on the Services Router. When the router is powered on, it is ready to be configured. If the router does not have a configuration from the factory or your service provider, you must configure the software to establish basic connectivity. If you are setting up a Services Router for the first time, you can use either J-Web Quick Configuration or a configuration editor to configure basic connectivity.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 54: Basic Connectivity Terms (continued) Term Definition Dynamic Host Configuration Protocol (DHCP) Protocol for assigning dynamic IP addresses to devices on a network. gateway Packets destined for IP addresses not identified in the routing table are sent to the default gateway. hostname Unique name that identifies a router on the network. loopback address IP address of a Services Router on logical interface lo0.
Chapter 7: Establishing Basic Connectivity among all the devices in a given network. Together the hostname and domain name identify the router in the network. Root Password The root user has complete privileges to configure the Services Router, and manage files in the router's file system. Initially, the root password is not defined on the router. To ensure basic security, you must define the root password during initial configuration.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Network Settings A Domain Name System (DNS) server on the network maintains a database for resolving hostnames and IP addresses. Network devices can query the DNS server by hostnames rather than IP addresses. The router accesses the DNS servers that are added to the configuration to resolve hostnames in the order in which you list them.
Chapter 7: Establishing Basic Connectivity Built-In Ethernet Interface Address The built-in Gigabit Ethernet interfaces, ge-0/0/0 through ge-0/0/3, on the front panel of the Services Router, are the interfaces through which you perform initial router setup. The examples in this guide use the ge-0/0/0 interface as the management interface, but you can use any built-in Ethernet port for management.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide TCP connection without using any additional protocol (such as SSH, SSL, or Telnet). Information sent in clear text is not encrypted and therefore can be intercepted. For more information about the JUNOScript application programming interface (API), see the JUNOScript API Guide. If the router is operating in a Common Criteria environment, see the Secure Configuration Guide for Common Criteria and JUNOS-FIPS.
Chapter 7: Establishing Basic Connectivity ■ ■ An Ethernet cable (provided) If you are performing the initial configuration with the CLI, collect the following equipment: ■ A management device, such as a PC or laptop, with a serial port and an asynchronous terminal application (such as Microsoft Windows Hyperterminal) ■ An RJ-45 to DB-9 serial port adapter (provided) ■ An Ethernet cable (provided) ■ For a remote connection, two dial-up modems ■ For a remote modem connection, a DB-9 female to DB-
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 4. Connect the other end of the Ethernet cable to the built-in Ethernet port on the router. 5. Power on the router by pressing the power button on the front panel. 6. Wait until the STATUS LED on the front panel turns solid green. 7. Turn on the power to the management device. The router assigns an IP address to the management device within the 192.168.1.0/24 subnetwork if the device is configured to use DHCP. 8.
Chapter 7: Establishing Basic Connectivity Figure 65: Connecting to the Gigabit Ethernet Port on J4350 and J6350 Routers Connecting to the CLI Locally If you plan to use the CLI to configure the router, you must connect through the console port, as shown in Figure 66 on page 138 and Figure 67 on page 139. NOTE: Figure 66 on page 138 and Figure 67 on page 139 show a connection to a local management device.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 8. 9. Configure the port settings as follows: ■ Bits per second: 9600 ■ Data bits: 8 ■ Parity: None ■ Stop bits: 1 ■ Flow control: None Power on the router by pressing the power button on the front panel. Verify that the POWER LED on the front panel turns green. The terminal emulation screen on your management device displays the boot sequence. When the router has finished booting, a login prompt appears. 10.
Chapter 7: Establishing Basic Connectivity Figure 67: Connecting to the Console Port on J4350 and J6350 Routers Connecting to the CLI Remotely You can connect to the CLI from a remote location through two dial-up modems: a modem that is connected to the console port on the Services Router and a second modem connected to a remote management device. The modem connection allows you to remotely perform the same console operations you can perform locally.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 3. From the PC or laptop computer, start your asynchronous terminal emulation application (such as Microsoft Windows Hyperterminal) and select the COM port to which the modem is connected (for example, COM1). 4. Configure the port settings as follows: 5. ■ Bits per second: 9600 ■ Data bits: 8 ■ Parity: None ■ Stop bits: 1 ■ Flow control: None In the HyperTerminal window, enter AT.
Chapter 7: Establishing Basic Connectivity Connecting to the CLI at the User End To remotely connect to the CLI through a dial-up modem connected to the console port on the router: 1. At your remote location, connect a modem to a management device such as a PC or laptop computer. 2. On the PC or laptop computer, start your asynchronous terminal emulation application (such as Microsoft Windows Hyperterminal). 3. Select the COM port to which the modem is connected (for example, COM1). 4.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 68: Set Up Quick Configuration Page Before you configure the router, gather the information described in “Before You Begin” on page 134. To configure basic settings with J-Web Quick Configuration: 142 ■ 1. If you have not already done so, connect a management device to the ge-0/0/0 interface on port 0/0. For instructions, see “Connecting to the J-Web Interface” on page 135. 2.
Chapter 7: Establishing Basic Connectivity ■ To cancel your entries and return to the Quick Configuration page, click Cancel. NOTE: After initial configuration is complete, the Services Router stops functioning as a DHCP server. If you change the IP address of ge-0/0/0 and have the management device configured to use DHCP, you lose your DHCP lease and your connection to the router through the J-Web interface.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 55: Set Up Quick Configuration Summary (continued) Field Function Your Action Current System Time Synchronizes the system time with the NTP server, or manually set the system time and date. ■ To immediately set the time using the NTP server, click Set Time via NTP. The router sends a request to the NTP server and synchronizes the system time.
Chapter 7: Establishing Basic Connectivity Configuring Basic Settings with a Configuration Editor To establish basic connectivity on a Services Router, you identify the router, connect the router to the network, and specify basic network settings. In a typical network, the Services Router has the basic settings listed in Table 56 on page 145. Determine the values to set on the Services Router in your network.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 3. If you are using the J-Web interface, click Commit to view a summary of your changes, then click OK to commit the configuration. If you are using the CLI, commit the configuration by entering the commit command. 4. To check the configuration, see Displaying Basic Connectivity Configurations on page 149.
Chapter 7: Establishing Basic Connectivity Table 57: Configuring Basic Settings (continued) Task J-Web Configuration Editor CLI Configuration Editor Define the NTP server that NTP requests can be sent to. 1. In the Nested configuration section, next to Ntp, click Configure or Edit. Set the address of the NTP server. For example: 2. Next to Server, click Add New Entry. 3. In the Address box, type the NTP server's IP address—for example, 10.148.2.21 4. Click OK. 5.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 57: Configuring Basic Settings (continued) Task J-Web Configuration Editor CLI Configuration Editor Define the IP address for ge-0/0/0. 1. In the configuration editor hierarchy, next to Interfaces, click Configure or Edit. 1. 2. In the Interface table, locate the ge-0/0/0 row and click Unit. 3. In the Unit table, click 0, and in the Family section next to Inet, click Configure or Edit. 4.
Chapter 7: Establishing Basic Connectivity Displaying Basic Connectivity Configurations Purpose Verify the configuration of basic connectivity. Because the basic connectivity settings appear in different places in the configuration hierarchy, displaying the entire configuration at once makes viewing the settings easier. Action From the J-Web interface, select Configuration>View and Edit>View Configuration Text. Alternatively, from configuration mode in the CLI, enter the show command.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 150 ■ Displaying Basic Connectivity Configurations
Chapter 8 Configuring Secure Web Access You can manage a Services Router remotely through the J-Web interface. To communicate with the router, the J-Web interface uses Hypertext Transfer Protocol (HTTP). HTTP allows easy Web access but no encryption. The data that is transmitted between the Web browser and the router by means of HTTP is vulnerable to interception and attack. To enable secure Web access, a router supports Hypertext Transfer Protocol over Secure Sockets Layer (HTTPS).
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 58: Secure Web Access Terms (continued) Term Definition Hypertext Transfer Protocol over Secure Sockets Layer (HTTPS) Protocol similar to HTTP with an added encryption layer that encrypts and decrypts user page requests and pages that are returned by a Web server. HTTPS is used for secure communication, such as payment transactions.
Chapter 8: Configuring Secure Web Access ■ Obtain an SSL certificate from a trusted signing authority. See “Generating SSL Certificates” on page 153. Generating SSL Certificates To enable secure Web access, you must first generate a digital SSL certificate, and then enable HTTPS access on the Services Router. To generate an SSL certificate: 1. Enter the following openssl command in your Secure Shell command-line interface.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 69: Quick Configuration Secure Access Page To configure Web access settings in the J-Web interface: 154 ■ 1. Enter information into the Secure Access Quick Configuration page, as described in Table 59 on page 155. 2. Click one of the following buttons: ■ To apply the configuration and stay on the Quick Configuration page, click Apply. ■ To apply the configuration and return to the Quick Configuration page, click OK.
Chapter 8: Configuring Secure Web Access 3. 4. To verify that Web access is enabled correctly, connect to the router using one of the following methods: ■ For HTTP access—In your Web browser, type http://URL or http://IP address. ■ For HTTPS access—In your Web browser, type https://URL or https://IP address. ■ For SSL JUNOScript access—A JUNOScript client such as JUNOScope is required. For information about how to log in to JUNOScope, see the JUNOScope Software User Guide.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 59: Secure Access Quick Configuration Summary (continued) Field Function Your Action Enable HTTPS on All Interfaces Enables HTTPS on all interfaces at one time. To enable HTTPS on all interfaces, select the Enable HTTPS on All Interfaces check box. HTTPS-Enabled Interfaces Allows you to specify interfaces on which you want to enable HTTPS access.
Chapter 8: Configuring Secure Web Access Table 60: Configuring a Secure Web Access (continued) Task J-Web Configuration Editor CLI Configuration Editor Import the SSL certificate that you have generated—for example, new. 1. Next to Certificates, click Configure. Enter 2. Next to Local, click Add new entry. 3. In the Name box, type a name for the certificate to be imported—for example, new. For information about generating SSL certificates, see “Generating SSL Certificates” on page 153. 4.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Displaying an SSL Certificate Configuration Purpose Action Display the SSL certificate configuration. From the J-Web interface, select Configuration>View and Edit>View Configuration Text. Alternatively, from configuration mode in the CLI, enter the show security command. The following sample output displays an SSL certificate generated with instructions in “Generating SSL Certificates” on page 153.
Chapter 8: Configuring Secure Web Access Displaying a Secure Access Configuration Purpose Action Verify the secure access configuration. From the J-Web interface, select Configuration>View and Edit>View Configuration Text. Alternatively, from configuration mode in the CLI, enter the show system services command. The following sample output displays the sample values for secure Web access as configured in Table 60 on page 156.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 160 ■ Displaying a Secure Access Configuration
Chapter 9 Installing and Managing J-series Licenses To enable some JUNOS software features on a J-series Services Router, you must purchase, install, and manage separate software licenses. The presence on the router of the appropriate software license keys (passwords) determines the features you can configure and use. For information about how to purchase J-series software licenses, contact your Juniper Networks sales representative.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 61: J-series Services Router Software Feature Licenses (continued) Licensed Software Feature License Name Data link switching (DLSw) on all J-series Services Routers J-series Services Router Software License for Data Link Switching (DLSw) Support Traffic Analysis J-Flow traffic analysis—all configuration statements within the [edit forwarding-options sampling] and [edit forwarding-options accounting] hierarchies.
Chapter 9: Installing and Managing J-series Licenses Managing J-series Licenses with the J-Web Interface To manage licenses with the J-Web interface, you perform the following tasks: ■ Adding New Licenses with the J-Web Interface on page 164 ■ Deleting Licenses with the J-Web Interface on page 165 ■ Displaying License Keys with the J-Web Interface on page 165 ■ Downloading Licenses with the J-Web Interface on page 165 Figure 70 on page 163 shows the J-Web Licenses page.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 62: Summary of License Management Fields (continued) Field Name Definition Feature Name of the licensed feature: ■ J-series licenses listed in Table 61 on page 161. ■ All features—All-inclusive licenses Licenses Used Number of licenses currently being used on the router. Usage is determined by the configuration on the router. If a feature license exists and that feature is configured, the license is considered used.
Chapter 9: Installing and Managing J-series Licenses Deleting Licenses with the J-Web Interface To delete one or more license keys from a Services Router with the J-Web license manager: 1. In the J-Web interface, select Manage>Licenses. 2. Select the check box of the license or licenses you want to delete. 3. Click Delete. 4. Go on to “Verifying J-series License Management” on page 167.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 1. Enter operational mode in the CLI. 2. Enter one of the following CLI commands: ■ To add a license key from a file or URL, enter the following command, specifying the filename or the URL where the key is located: request system license add filename | url ■ To add a license key from the terminal, enter the following command: request system license add terminal 3.
Chapter 9: Installing and Managing J-series Licenses Verifying J-series License Management To verify J-series license management, perform these tasks: ■ Displaying Installed Licenses on page 168 ■ Displaying License Usage on page 169 ■ Displaying Installed License Keys on page 169 Verifying J-series License Management ■ 167
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Displaying Installed Licenses Purpose Action Verify that the expected licenses are installed and active on the Services Router. From the CLI, enter the show system license command.
Chapter 9: Installing and Managing J-series Licenses Displaying License Usage Purpose Action Verify that the licenses fully cover the feature configuration on the Services Router. From the CLI, enter the show system license usage command. user@router> show system license usage Licenses Licenses Feature name used j-flow 0 bgp-reflection 1 dlsw 1 What It Means Licenses installed 0 1 1 needed 1 0 0 The output shows a list of the licenses installed on the Services Router and how they are used.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 170 ■ Displaying Installed License Keys
Part 3 Maintaining Services Router Hardware ■ Replacing Hardware Components on page 173 ■ Troubleshooting Hardware Components on page 211 ■ Contacting Customer Support and Returning Hardware on page 215 Maintaining Services Router Hardware ■ 171
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 172 ■ Maintaining Services Router Hardware
Chapter 10 Replacing Hardware Components Because many of the Services Router's hardware components are field-replaceable units (FRUs), you can remove and replace them yourself. When you need to replace a router component, contact your customer support or sales representative to order the field-replaceable unit (FRU) that contains the component. For instructions, see “Contacting Customer Support and Returning Hardware” on page 215.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 63: Tools and Parts Required Tool or Part Components Electrostatic bag or antistatic mat All Electrostatic discharge (ESD) grounding wrist strap All Flat-blade screw-blade screwdriver, approximately 1/4 in.
Chapter 10: Replacing Hardware Components CAUTION: Do not hot-swap PIMs. Failure to power off the router before removing or installing a PIM might result in damage to the hardware. Figure 71: Removing a PIM To remove a PIM (see Figure 71 on page 175): 1. Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the PIM. 2.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Installing a PIM CAUTION: Do not hot-swap PIMs. Failure to power off the router before removing or installing a PIM might result in damage to the hardware. Figure 72: Installing a PIM CAUTION: Do not install a combination of PIMs in a single chassis that exceeds the maximum power and heat capacity of the chassis.
Chapter 10: Replacing Hardware Components 6. 7. If necessary, arrange the cables to prevent them from dislodging or developing stress points: ■ Secure each cable so that it is not supporting its own weight as it hangs to the floor. ■ Place excess cable out of the way in a neatly coiled loop. ■ Use fasteners to maintain the shape of cable loops. Press and release the power button to power on the router. Verify that the POWER LED lights steadily.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 3. Arrange the cable as necessary to prevent it from dislodging or developing stress points: ■ Secure the cable so that it is not supporting its own weight as it hangs to the floor. ■ Place excess cable out of the way in a neatly coiled loop. ■ Use fasteners to maintain the shape of cable loops. 4. Insert the other end of the cable into the destination port. 5. Repeat the previous steps for any additional cables. 6.
Chapter 10: Replacing Hardware Components 5. With a Phillips screwdriver remove the flat head screws from the rear and sides of the chassis. 6. Position the router so that you face the front panel. 7. Place your hands on the cover and press down while pushing the cover back until the two front tabs disengage from the chassis base (see Figure 73 on page 179). Figure 73: Sliding the Chassis Cover 8.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 75: Matching the Chassis Slots and Tabs 3. Lower the cover fully onto the base, and slide it so that the front tabs match the front slots and the chassis cover and base edges align completely. 4. Insert and tighten the flat head screws with a Phillips screwdriver. 5. Return the router to its installation site, and attach the grounding cable and the power cables. (See “Connecting Power” on page 122.) 6.
Chapter 10: Replacing Hardware Components Figure 76: Location of J2320 and J2350 Internal Compact Flash To replace the internal compact flash: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface. 2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 77: Removing the J2320 or J2350 Internal Compact Flash 9. Place the compact flash on the antistatic mat or in the electrostatic bag. 10. With the vendor name and memory size facing up and the arrow pointing towards the router, insert the new compact flash into the compact flash slot (see Figure 78 on page 182). Figure 78: Inserting the J2320 or J2350 Internal Compact Flash 11. Replace the compact flash slot cover. 12.
Chapter 10: Replacing Hardware Components Replacing Internal Compact Flashes on J4350 and J6350 Routers The internal compact flash is installed in a slot on the bottom of the J4350 or J6350 chassis (see Figure 79 on page 183). NOTE: Use only compact flash cards purchased from Juniper Networks for your J-series platform and model.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 80: Alternative Horizontal Orientation of J4350 and J6350 Compact Flash To replace the compact flash: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface. 2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground.
Chapter 10: Replacing Hardware Components Figure 81: Removing the J4350 or J6350 Compact Flash 8. Place the compact flash on the antistatic mat or in the electrostatic bag. 9. Slide the new compact flash into the slot and press down, as shown in Figure 82 on page 185. Figure 82: Inserting the J4350 or J6350 Compact Flash NOTE: On some Services Routers the compact flash is in a horizontal position.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 12. Replace the power cord or cable. 13. Press and release the power button to power on the router. Verify that the POWER LED lights steadily. Replacing External Compact Flashes The external compact flash is an optional component on J2320 and J2350 Services Routers. It provides secondary storage for the router and can accommodate software images, configuration files, and microcode.
Chapter 10: Replacing Hardware Components Skip this step, if the router did not boot from the external compact flash (see step 1). 5. With a Phillips screwdriver, loosen the pan head screws that secure the external compact flash cover to the rear of the chassis (see Figure 83 on page 187). Figure 83: Removing the External Compact Flash Cover 6. Remove the compact flash cover. 7.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 12. Tighten the pan head screws that secures the compact flash slot cover to the rear of the chassis. 13. Plug the power cord into the power supply. 14. Press and release the power button to power on the router. Verify that the POWER LED lights steadily. Replacing USB Storage Devices USB storage devices are optional components on J-series Services Routers. If installed, a USB storage device provides secondary storage for the router.
Chapter 10: Replacing Hardware Components 1. Verify the device that the router used to boot, by running the show system storage command from the CLI. For example: user@host> show system storage Filesystem /dev/ad0s1a ... 512-blocks 218254 Used 175546 Avail Capacity Mounted on 40526 81% / The boot device is mounted on /. The internal compact flash is located at ad0. The external compact flash is located at ad2. The USB storage device is located at da0.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 3. Insert the USB storage device into the USB port. If the USB storage device does not easily slide into the port, it might not be oriented correctly. Turn the USB storage device upside-down and try again. 4. To configure the USB storage device with the request system snapshot command, see the J-series Services Router Administration Guide.
Chapter 10: Replacing Hardware Components Figure 87: J4350 and J6350 DRAM Location To modify the DRAM configuration, use the following procedures: ■ Removing a DRAM Module on page 191 ■ Installing a DRAM Module on page 192 Removing a DRAM Module To remove a DRAM module: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface. 2.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 88: Installing or Replacing DRAM Modules Installing a DRAM Module J2320, J2350, J4350 and J6350 Services Routers support 256-MB and 512-MB DRAM modules. Use only DRAM modules purchased from Juniper Networks specifically for your model. NOTE: If you are installing a second DRAM module, do not install it in a slot adjacent to the first module.
Chapter 10: Replacing Hardware Components 5. Pressing firmly on both ends, push the module into the slot until the ejectors click into the closed position (see Figure 88 on page 192). 6. Slide the cover onto the chassis. 7. Replace and tighten the screws on the sides and top of the chassis that secure the cover to the chassis. 8. Replace the power cord or cable. 9. Press and release the power button to power on the router. Verify that the POWER LED lights steadily. 10.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 1. Locate a replacement power cord with the type of plug appropriate for your geographical location (see “AC Power, Connection, and Power Cord Specifications” on page 107). 2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground.
Chapter 10: Replacing Hardware Components NOTE: If the power supply is a redundant power supply in a J6350 Service Router, you can leave the router powered on and power flowing in the other power supply. 3. Unplug the power cord from the power source receptacle. 4. Unplug the power cord from the appliance inlet on the power supply faceplate. 5. Slide the ejector tab on the power supply faceplate to the right and hold it in place to unlock the power supply. 6.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide NOTE: Each power supply must be connected to a dedicated AC power feed. For information about connecting to AC power sources, see “Connecting Power” on page 122. 6. Verify that the power cord does not block access to router components or drape where people might trip on it. 7. Press and release the power button to power on the router. Verify that the POWER LED lights steadily.
Chapter 10: Replacing Hardware Components CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply. 5. Remove the power cable from the DC power source. 6.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply. 4.
Chapter 10: Replacing Hardware Components 1. Ensure that the voltage across the DC power source cable leads is 0 V and that the cable leads cannot become active during installation. CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 92: Installing a DC Power Supply Replacing Crypto Accelerator Modules on J2320 and J2350 Routers The Crypto Accelerator Module is a processor card that enhances performance of cryptographic algorithms used in IP security (IPSec) services. The Crypto Module is an optional feature on J2320 and J2350 Services Routers. Figure 93 on page 200 shows the location of the Crypto Accelerator Module on J2320 and J2350 routers.
Chapter 10: Replacing Hardware Components Removing a J2320 or J2350 Crypto Accelerator Module NOTE: If you are installing a Crypto Accelerator Module into a J2320 or J2350 Services Router for the first time, proceed directly to “Installing a J2320 or J2350 Crypto Accelerator Module” on page 202. To remove the Crypto Accelerator Module: 1. Place an electrostatic bag or antistatic mat on a flat stable surface to receive the Crypto Module. 2.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Installing a J2320 or J2350 Crypto Accelerator Module To install a Crypto Accelerator Module: 1. Take the following steps if you have not already done so: a. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground.
Chapter 10: Replacing Hardware Components 8. Press and release the power button to power on the router. Verify that the POWER LED lights steadily. 9.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 96: Crypto Accelerator Module Location on J4350 and J6350 Routers To modify a Crypto Accelerator Module configuration, use the following procedures: ■ Removing a J4350 or J6350 Crypto Accelerator Module on page 204 ■ Installing a J4350 or j6350 Crypto Accelerator Module on page 205 Removing a J4350 or J6350 Crypto Accelerator Module NOTE: If you are installing a Crypto Accelerator Module into a J4350 Services Router for the fi
Chapter 10: Replacing Hardware Components 6. Locate the Crypto Module on the system board (see Figure 96 on page 204). 7. Using a Phillips screwdriver remove the screw, as shown in Figure 97 on page 205. Figure 97: Removing a J4350 or J6350 Crypto Module Screw 8. Pull the white release clips on either side of the Crypto Module out to either side, as shown in Figure 98 on page 205, to tilt the Crypto Module upward. Figure 98: Removing and Installing a J4350 or J6350 Crypto Accelerator Module 9.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide a. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 249. b. Press and release the power button to power off the Services Router. Wait for the POWER LED to turn off. c.
Chapter 10: Replacing Hardware Components Replacing Air Filters on J2350 Routers The cooling fans on J2350 routers draw air through vents along the left side of the chassis and exhaust it through vents on the right side of the chassis. For more information, see “J2320 and J2350 Cooling System” on page 25. On J2350 routers that comply with Network Equipment Building System (NEBS) criteria, the air intake grid contains a filter.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 100: Placing the Air Filter on the Air Filter Tray 6. Press down on the filter until it is firmly seated against the bottom of the tray. 7. Hold the filter tray with the thumbscrew so that its sheet metal side faces the power supply fan exhaust. The air filter tray is designed to prevent it from being inserted incorrectly (see Figure 101 on page 208). Figure 101: Inserting the Air Filter Tray on J2350 Routers 8.
Chapter 10: Replacing Hardware Components Figure 102: Attaching Air Filter and Filter Cover We recommend changing the filter every 6 months. However, the optimal filter replacement interval can vary depending on the environment where the router is located. If temperature alarms appear, inspect the air filter. To replace the air filter: 1. Remove the filter cover by squeezing the plastic tabs on either side of the filter cover. 2. Pull the filter cover away from the chassis. 3. Remove the old filter.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 210 ■ Replacing Air Filters on J4350 and J6350 Routers
Chapter 11 Troubleshooting Hardware Components This chapter contains the following topics: ■ Chassis Alarm Conditions on page 211 ■ Troubleshooting Power Management on page 212 ■ Contacting the Juniper Networks Technical Assistance Center on page 214 Chassis Alarm Conditions You can monitor alarms to troubleshoot hardware problems on a Services Router. Alarms alert you to conditions on the router chassis, or in the system software that might prevent the router from operating normally.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 64: Chassis Alarm Conditions and Corrective Actions (continued) Component Alarm Conditions Corrective Action Alarm Severity PIM A PIM has failed. Replace the failed PIM. (See “Replacing a PIM” on page 174.) Red (major) Reformat the compact flash and install a bootable image. (See the J-series Services Router Administration Guide.) Yellow (minor) When a PIM fails, it attempts to reboot.
Chapter 11: Troubleshooting Hardware Components To bring the PIM online: 1.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide user@host# set chassis fpc 2 offline If the power and heat tokens no longer exceed the maximum, the PIMs that were placed offline by J-series power management are brought online automatically. ■ Use the set chassis disable_power_management command to disable J-series power management: user@host# set chassis disable_power_management CAUTION: Use extreme caution when disabling J-series power management.
Chapter 12 Contacting Customer Support and Returning Hardware This chapter describes how to return the Services Router or individual components to Juniper Networks for repair or replacement.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide The following sections describe the label location on each type of component: ■ J2320 and J2350 Chassis Serial Number and Agency Labels on page 216 ■ J4350 and J6350 Chassis Serial Number and Agency Labels on page 217 ■ PIM Serial Number Label on page 218 ■ Power Supply Serial Number Labels on page 218 J2320 and J2350 Chassis Serial Number and Agency Labels J2320 and J2350 Services Routers have serial number ID labels located on t
Chapter 12: Contacting Customer Support and Returning Hardware Figure 104: Location of the Agency Labels J4350 and J6350 Chassis Serial Number and Agency Labels J4350 and J6350 Services Routers have serial number ID labels on the back of the chassis, as shown in Figure 105 on page 217, and an agency label on the bottom front corner, as shown in Figure 106 on page 218.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Figure 106: Location of the Agency Labels PIM Serial Number Label PIMs are field-replaceable. Each PIM has a unique serial number. The serial number label is located on the right side of the PIM, when the PIM is horizontally oriented (as it would be installed in the router). The exact location might be slightly different on different PIMs, depending on the placement of components on the PIM board.
Chapter 12: Contacting Customer Support and Returning Hardware From all other locations: 1-408-745-9500 If contacting JTAC by telephone, enter your 11-digit case number followed by the pound (#) key if this is an existing case, or press the star (*) key to be routed to the next available support engineer.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide The support representative validates your request and issues an RMA number for return of the component. 4. Pack the router or component for shipment, as described in “Packing a Router or Component for Shipment” on page 220.
Chapter 12: Contacting Customer Support and Returning Hardware 4. Shut down power to the router by pressing the power button on the front panel of the router. 5. Disconnect power from the router. For instructions, see “Replacing AC Power Supply Cords” on page 193 and “Replacing DC Power Supply Cables” on page 196. 6. Remove the cables that connect to all external devices. For instructions, see “Removing PIM Cables” on page 177. 7. Remove all field-replaceable units (FRUs) from the router. 8.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 222 ■ Packing a Router or Component for Shipment
Part 4 J-series Requirements and Specifications ■ Network Cable Specifications and Connector Pinouts on page 225 ■ Safety and Regulatory Compliance Information on page 245 J-series Requirements and Specifications ■ 223
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 224 ■ J-series Requirements and Specifications
Chapter 13 Network Cable Specifications and Connector Pinouts The network interfaces supported on the router accept different kinds of network cable.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 65: 2-Port Serial PIM Cables and Connectors (continued) Name Connector Connector Hardware End-to-End Conductors Pinouts RS-422/449 (EIA-449) DCE DC-37 (DB-37) female 4-40 threaded jacknuts 25 Table 69 on page 229 EIA-530A DTE DB-25 male 4-40 threaded jackscrews 23 Table 70 on page 230 EIA-530A DCE DB-25 female 4-40 threaded jacknuts 22 Table 71 on page 231 V.
Chapter 13: Network Cable Specifications and Connector Pinouts Table 66: RS-232 DTE Cable Pinout (continued) LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 52 24 – Terminal Clock 22 to 21 – – – 18 to 17 – – – RS-232 DCE Cable Pinout Table 67: RS-232 DCE Cable Pinout LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 15 1 – Frame Ground 1 2 – Transmit Data 60 3 – Receive Data 37 4 – Request to Send 48 5 – Clear to Send 33 6 – Data Set Ready 57 7 – Signal Ground
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 68: RS-422/449 (EIA-449) DTE Cable Pinout (continued) LFH-60 Pin DC-37 (DB-37) Pin LFH-60 Pairing Description 60 4 59 Send Data (A) 56 5 55 Send Timing (A) 1 6 2 Receive Data (A) 48 7 47 Request to Send (A) 5 8 6 Receive Timing (A) 37 9 38 Clear to Send (A) 41 10 – Local Loopback 9 11 10 Data Mode (A) 33 12 34 Terminal Ready (A) 13 13 14 Receive Ready (A) 52 17 51 Terminal Timing (A) 3
Chapter 13: Network Cable Specifications and Connector Pinouts RS-422/449 (EIA-449) DCE Cable Pinout Table 69: RS-422/449 (EIA-449) DCE Cable Pinout LFH-60 Pin DC-37 (DB-37) Pin LFH-60 Pairing Description 15 1 – Shield Ground 1 4 2 Send Data (A) 56 5 55 Send Timing (A) 60 6 59 Receive Data (A) 37 7 38 Request to Send (A) 52 8 51 Receive Timing (A) 48 9 47 Clear to Send (A) 45 10 – Local Loopback 33 11 34 Data Mode (A) 9 12 10 Terminal Ready (A) 13 13 14 Receiv
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide EIA-530A DTE Cable Pinout Table 70: EIA-530A DTE Cable Pinout LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 15 1 – Shield Ground 60 2 59 Transmit Data (A) 1 3 2 Receive Data (A) 48 4 47 Request to Send (A) 37 5 38 Clear to Send (A) 9 6 – Data Set Ready (A) 57 7 – Signal Ground 13 8 14 Received Line Signal Detector (A) 6 9 5 Receive Clock (B) 14 10 13 Received Line Signal Detector (B) 51 11 5
Chapter 13: Network Cable Specifications and Connector Pinouts EIA-530A DCE Cable Pinout Table 71: EIA-530A DCE Cable Pinout LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 15 1 – Shield Ground 1 2 2 Transmit Data (A) 60 3 59 Receive Data (A) 37 4 38 Request to Send (A) 48 5 47 Clear to Send (A) 33 6 – Data Set Ready (A) 57 7 – Signal Ground 13 8 14 Received Line Signal Detector (A) 51 9 52 Receive Clock (B) 14 10 13 Received Line Signal Detector (B) 6 11 5 Te
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide V.35 DTE Cable Pinout Table 72: V.
Chapter 13: Network Cable Specifications and Connector Pinouts V.35 DCE Cable Pinout Table 73: V.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 74: X.21 DTE Cable Pinout (continued) LFH-60 Pin DB-15 Pin LFH-60 Pairing Description 60 2 59 Transmit Data (A) 48 3 47 Control (A) 1 4 2 Receive (A) 37 5 38 Indicate (A) 5 6 6 Signal Element Timing (A) 57 8 – Signal Ground 59 9 60 Transmit Data (B) 47 10 48 Control (B) 2 11 1 Receive (B) 38 12 37 Indicate (B) 6 13 5 Signal Element Timing (B) 30 to 29 – – – 18 to 17 – – – X.
Chapter 13: Network Cable Specifications and Connector Pinouts Table 75: X.21 DCE Cable Pinout (continued) LFH-60 Pin DB-15 Pin LFH-60 Pairing Description 47 12 48 Indicate (B) 51 13 52 Signal Element Timing (B) 30 to 29 – – – Fast Ethernet RJ-45 Connector Pinout Table 76 on page 235 describes the Fast Ethernet RJ-45 connector pinout information. NOTE: Either a straight-through or cross-over cable can be used to connect to the interface.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 77: Gigabit Ethernet uPIM RJ-45 Connector Pinout (continued) Pin Signal Name Function 3 BI_DB+ Bidirectional pair +B 4 BI_DC+ Bidirectional pair +C 5 BI_DC- Bidirectional pair -C 6 BI_DB- Bidirectional pair -B 7 BI_DD+ Bidirectional pair +D 8 BI_DD- Bidirectional pair -D Gigabit Ethernet ePIM RJ-45 Connector Pinout Table 78 on page 236 describes connector pinout information for 1-port Gigabit Ethernet ePIM ports
Chapter 13: Network Cable Specifications and Connector Pinouts Table 79: RJ-45 Chassis Console Connector Pinout Pin Signal Description 1 RTS Output Request to Send 2 DTR Output Data Terminal Ready 3 TxD Output Transmit Data 4 GND Chassis Ground 5 GND Chassis Ground 6 RxD Input Receive Data 7 DSR Input Data Set Ready 8 CTS Input Clear to Send Table 80 on page 237 describes the DB-9 connector pinouts.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 81 on page 238 through Table 84 on page 239 describe the RJ-48 connector pinouts.
Chapter 13: Network Cable Specifications and Connector Pinouts Table 83: RJ-48 Connector to DB-15 Connector (Straight) Pinout DB-15 Pin RJ-48 Pin (on T1/E1 PIM) (Data Numbering Form) (Data Numbering Form) Signal 1 11 RX/Ring/– <––>RX/Ring/– 2 3 RX/Tip/+ <––>RX/Tip/+ 4 9 TX/Ring/– <––>TX/Ring/– 5 1 TX/Tip/+ <––>TX/Tip/+ 3 4 Shield/Return/Ground 6 2 Shield/Return/Ground 7 No connect No connect 8 No connect No connect 9 No connect No connect 10 No connect No connect 11 No con
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 84: RJ-48 Connector to DB-15 Connector (Crossover) Pinout (continued) DB-15 Pin RJ-48 Pin (on T1/E1 PIM) (Data Numbering Form) (Data Numbering Form) Signal 7 No connect No connect 8 No connect No connect 9 No connect No connect 10 No connect No connect 11 No connect No connect 12 No connect No connect 13 No connect No connect 14 No connect No connect 15 No connect No connect E3 and T3 BNC Connector Pino
Chapter 13: Network Cable Specifications and Connector Pinouts ISDN RJ-45 Connector Pinout The 1-port and 4-port ISDN PIMs use an RJ-45 cable, which is not supplied with the PIMs. Table 86 on page 241 describes the RJ-45 connector pinout.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide NOTE: Two different RJ-45 cables and RJ-45 to DB-9 adapters are provided. Do not use the RJ-45 cable and adapter for the Services Router console port to connect to the TGM550 console port. To connect the console port to an external management device, you need an RJ-45 to DB-9 serial port adapter, which is also supplied with the TGM550.
Chapter 13: Network Cable Specifications and Connector Pinouts TIM510 RJ-45 Connector Pinout The TIM510 Telephony Interface Module uses an RJ-45 cable. Table 89 on page 243 describes the TIM510 RJ-45 connector pinout. Table 89: TIM510 RJ-45 Connector Pinout Pin Signal 1 R - Receive 2 T - Receive 3 No connection 4 R1 - Receive 5 T1 - Receive 6 No connection 7 No connection 8 No connection TIM514 Connector Pinout The TIM514 Telephony Interface Module uses an RJ-11 cable.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Table 91: TIM521 RJ-45 Connector Pinout 244 ■ Pin Signal 1 No connection 2 No connection 3 Transmit pair + 4 Receive pair + 5 Receive pair – 6 Transmit pair – 7 No connection 8 No connection Connector Pinouts for Avaya VoIP Modules
Chapter 14 Safety and Regulatory Compliance Information To install and use the Services Router safely, follow proper safety procedures.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. WARNING: Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this manual. Such an action could cause severe electrical shock. ■ Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire. ■ Avoid spilling liquid onto the Services Router chassis or onto any Services Router component.
Chapter 14: Safety and Regulatory Compliance Information Preventing Electrostatic Discharge Damage Many Services Router hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ DC Power Electrical Safety Guidelines on page 252 ■ Power Sources for Redundant Power Supplies on page 252 ■ DC Power Disconnection Warning on page 253 ■ DC Power Grounding Requirements and Warning on page 254 ■ DC Power Wiring Sequence Warning on page 255 ■ DC Power Wiring Terminations Warning on page 256 ■ Grounded Equipment Warning on page 258 ■ Warning Statement for Norway and Sweden on page 258 ■ In Case of Electri
Chapter 14: Safety and Regulatory Compliance Information Many Services Router components can be removed and replaced without powering down or disconnecting power to the Services Router, as detailed in elsewhere in this manual. Never install equipment if it appears damaged.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide DC Power Electrical Safety Guidelines The following electrical safety guidelines apply to a DC-powered router: ■ A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 8 A @ –48 VDC.
Chapter 14: Safety and Regulatory Compliance Information DC Power Disconnection Warning WARNING: Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide de corrente contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora. ¡Atención! Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF).
Chapter 14: Safety and Regulatory Compliance Information ¡Atención! Al instalar el equipo, conectar la tierra la primera y desconectarla la última. Varning! Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist. DC Power Wiring Sequence Warning WARNING: Wire the DC power supply using the appropriate lugs. When connecting power, the proper wiring sequence is ground to ground, +RTN to +RTN, then -48 V to -48 V.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide La corretta sequenza di cablaggio è da massa a massa, da positivo a positivo (da linea ad L) e da negativo a negativo (da neutro a N). Tenere presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo. WARNING: Advarsel Riktig tilkoples tilkoplingssekvens er jord til jord, +RTN til +RTN, –48 V til – 48 V. Riktig frakoples tilkoplingssekvens er –48 V til – 48 V, +RTN til +RTN, jord til jord.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Varning! När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp. Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda. Grounded Equipment Warning WARNING: The router is intended to be grounded. Ensure that the router is connected to earth ground during normal use.
Chapter 14: Safety and Regulatory Compliance Information Varning! Apparaten skall anslutas till jordat nätuttag. In Case of Electrical Accident If an electrical accident results in an injury, take the following actions in this order: 1. Use caution. Be aware of potentially hazardous conditions that could cause further injury. 2. Disconnect power from the Services Router. 3. If possible, send another person to get medical aid. Otherwise, assess the condition of the victim, then call for help.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Advarsel Denne J6350 enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten. WARNING: Aviso Este J6350 dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA. WARNING: Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut på vekselstrømsenheter.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Avvertenza Il dispositivo è stato progettato per l'uso con sistemi di alimentazione TN. WARNING: Advarsel Utstyret er utfomet til bruk med TN-strømsystemer. WARNING: Aviso O dispositivo foi criado para operar com sistemas de corrente TN. WARNING: ¡Atención! El equipo está diseñado para trabajar con sistemas de alimentación tipo TN.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Avvertenza Per ridurre il rischio di incendio, usare solo un cavo per linea di telecomunicazioni di sezione 0,12 mm2 (26 AWG) o maggiore. WARNING: Advarsel Bruk kun AWG nr. 26 eller telekommunikasjonsledninger med større dimensjon for å redusere faren for brann. WARNING: Aviso Para reduzir o risco de incêndio, utilize apenas terminais de fio de telecomunicações Nº. 26 AWG ou superiores.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Installation Instructions Warning WARNING: Read the installation instructions before you connect the router to a power source. Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt. Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Chapter 14: Safety and Regulatory Compliance Information ■ When mounting the router in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. ■ If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the router in the rack.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel: ■ Le rack sur lequel est monté le Juniper Networks router doit être fixé à la structure du bâtiment. ■ Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten: ■ Juniper Networks router må installeres i et stativ som er forankret til bygningsstrukturen. ■ Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior. ■ Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Chapter 14: Safety and Regulatory Compliance Information Varning! Använd inte ramp med en lutning på mer än 10 grader. Laser and LED Safety Guidelines and Warnings Single-mode Physical Interface Modules (PIMs) are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S. Food and Drug Administration, and are evaluated as a Class 1 Laser Product per EN 60825–1 requirements.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Warnung Laserprodukt der Klasse 1. WARNING: Avvertenza Prodotto laser di Classe 1. Advarsel Laserprodukt av klasse 1. Aviso Produto laser de classe 1. ¡Atención! Producto láser Clase I. Varning! Laserprodukt av klass 1. Class 1 LED Product Warning WARNING: Class 1 LED product. Waarschuwing Klasse 1 LED-product. Varoitus Luokan 1 valodiodituote. Attention Alarme de produit LED Class I. Warnung Class 1 LED-Produktwarnung.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten. WARNING: Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla. WARNING: Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques. WARNING: Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen Geräten prüfen.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden. WARNING: Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Varning! Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte. Skift kun med samme eller tilsvarende type som er anbefalt av produsenten. Kasser brukte batterier i henhold til produsentens instruksjoner. WARNING: Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore.
Chapter 14: Safety and Regulatory Compliance Information lukien). Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin. WARNING: Attention Avant d'accéder à cet équipement connecté aux lignes électriques, ôter tout bijou (anneaux, colliers et montres compris).
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Varning! Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna. Lightning Activity Warning WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Varning! Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. Operating Temperature Warning WARNING: To prevent the router from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104οF (40οC). To prevent airflow restriction, allow at least 6 inches (15.2 cm) of clearance around the ventilation openings.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide WARNING: Advarsel Unngå overoppheting av eventuelle rutere i Juniper Networks router Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40οC (104οF). Sørg for at klaringen rundt lufteåpningene er minst 15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Chapter 14: Safety and Regulatory Compliance Information WARNING: Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden. WARNING: Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia WARNING: Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide ■ ■ ■ ■ FCC Part 68 ■ Industry Canada CS-03 EMC (J4320 and J6350) ■ AS/NZS 3548 Class B (Australia/New Zealand) ■ EN 55022 Class B Emissions (Europe) ■ FCC Part 15 Class B (USA) ■ VCCI Class B (Japan) ■ FCC Part 68 ■ Industry Canada CS-03 Immunity ■ EN 61000-3-2 Power Line Harmonics ■ EN 61000-3-3 Voltage Fluctuations and Flicker ■ EN 61000-4-2 ESD ■ EN 61000-4-3 Radiated Immunity ■ EN 61000-4-4 EFT ■ EN 6100
Chapter 14: Safety and Regulatory Compliance Information ■ Japan on page 283 ■ United States on page 284 Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide European Community 282 ■ Compliance Statements for EMC Requirements
Chapter 14: Safety and Regulatory Compliance Information Japan The preceding translates as follows: This is a Class B product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this product is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide United States The Services Router has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Chapter 14: Safety and Regulatory Compliance Information If trouble is experienced with this equipment or for repair or warranty information, please follow the applicable procedures explained in the “Technical Support” section of this manual. ■ FCC Registration Number—See label on product. ■ Required Connector (USOC)—RJ-48C ■ Service Order Code (SOC)—6.
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 286 ■ Compliance Statements for EMC Requirements
Part 5 Index ■ Index on page 289 Index ■ 287
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 288 ■ Index
Index Symbols #, comments in configuration statements.................xviii #, configuration mode command prompt....................91 ( ), in syntax descriptions..........................................xviii * (red asterisk).............................................................84 4-Port Fast Ethernet ePIM............................................62 4-Port ISDN BRI S/T PIM description............................................................63 PIM ONLINE LED......................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide analog telephone (LINE) ports TGM550, pinouts................................................242 TIM514, pinouts..................................................243 TIM514, possible configurations...........................75 analog trunk (TRUNK) ports TGM550, pinouts................................................242 TIM514, pinouts..................................................243 TIM514, possible configurations.....................
Index chassis console port, DB-9 connector pinouts............................................................237 chassis console port, RJ-45 connector pinouts............................................................236 connecting to network media.............................121 console port cable (chassis), connecting..............................................137, 140 console port cable (chassis), replacing................174 DC cables See DC power cables disconnecting PIM cables....................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide compact flash backup, replacing................................................186 description......................................................18, 31 external, description.............................................24 external, J2320 and J2350....................................24 external, replacing..............................................186 inserting.............................................................
Index J4350 system........................................................36 J6350 system........................................................37 power disconnection warning.............................253 removing a J6350 power supply.........................197 requirements......................................................106 safety guidelines (general)...................................252 safety guidelines, power sources for redundant power supplies................................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide EMI (electromagnetic interference) compliance with requirements............................280 standards............................................................279 suppressing.........................................................106 encrypted access through HTTPS...................................................151 through SSH........................................................134 through SSL...................................
Index RJ-45 connector pinouts (uPIMs).........................235 SFP (optical)....................................................51, 53 Gigabit Ethernet uPIMs alarms...................................................................52 description............................................................49 installation............................................................51 LEDs.....................................................................52 limitations......................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide requirements......................................................115 restricted access, J2350......................................117 restricted access, J4350 and J6350............................................25, 37, 38, 118 safety guidelines and warnings...........................263 site checklist.......................................................112 site guidelines.....................................................
Index J2350 air filter, replacing...............................................207 Avaya VoIP modules.............................................67 boot devices..........................................................19 boot sequence......................................................19 chassis..................................................................14 chassis cover, replacing......................................178 compact flash location........................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Routing Engine, hardware.....................................31 T3 PIM..................................................................59 TGM550................................................................69 TIM510.................................................................73 TIM514.................................................................74 TIM521.................................................................
Index SHDSL port status.................................................67 SIG (signal)............................................................74 STATUS (router)..............................................21, 34 T1 port status........................................................57 T3 port status........................................................60 TGM550 port status..............................................72 TIM510 link status................................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide minor (yellow) alarms alternative boot device........................................211 internal compact flash........................................211 Routing Engine...................................................212 modem commands at remote end.....................................................141 at router end.......................................................
Index pinouts ADSL RJ-11 connector.........................................240 Avaya VoIP modules...........................................241 chassis console DB-9 connector..........................237 chassis console port............................................236 EIA-530A DCE serial cable..................................231 EIA-530A DTE serial cable..................................230 Fast Ethernet connector......................................235 Gigabit Ethernet connector (ePIM)...............
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide removing DC.......................................................197 serial number label.............................................218 power system connecting..................................................123, 124 fan..................................................................25, 38 J2320....................................................................24 J4350.................................................................
Index RJ-48 connector to DB-15 connector (crossover) pinouts...................................................................239 RJ-48 connector to DB-15 connector (straight) pinouts...................................................................239 RJ-48 connector to RJ-48 connector (crossover) pinouts...................................................................238 RJ-48 connector to RJ-48 connector (straight) pinouts...................................................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide EIA-530A DCE pinouts........................................231 EIA-530A DTE pinouts........................................230 LED states.............................................................56 RS-232 DCE pinouts............................................227 RS-232 DTE pinouts............................................226 RS-422/449 (EIA-449) DCE pinouts.....................229 RS-422/449 (EIA-449) DTE pinouts...................
Index slot numbers, PIM chassis diagram..............................................20, 33 displayed as FPC number in command output.............................................................178 small form-factor pluggable transceivers See SFP SNMP (Simple Network Management Protocol), no Gigabit Ethernet support.....................................51, 54 software.......................................................................39 features............................................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide Telephony Interface Modules See TIM510; TIM514; TIM521 Telnet defining access (Quick Configuration).................144 management access...........................................133 temperature required for operation.........................................104 Routing Engine, too warm..................................212 shutdown, NEBS-compliant routers.................25, 38 shutdown, non-NEBS-compliant routers................
Index W warnings battery handling.................................................273 DC power cables.................................................252 DC power disconnection.....................................253 DC power plant and chassis ground....................109 DC wiring sequence............................................255 DC wiring terminations.......................................256 DC-powered J4350, and J6350 routers, restricted access installation only .................................
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide 308 ■ Index