Network Router User Manual

NOTE: The values given in the usb0 rows provide information for USB level debugging.
This information is about USB hub topology.
show chassis environment
user@host > show chassis environment
Class Item Status Measurement
Temp Routing Engine OK 33 degrees C / 91 degrees F
Fans SRX210 Chassis fan OK Spinning at intermediate-speed
Power Power Supply 0 OK
show chassis fpc
user@host > show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online -------------------- CPU less FPC --------------------
1 Online -------------------- CPU less FPC --------------------
show chassis alarms
user@host > show chassis alarms
Alarm time Class Description
2009-05-11 10:47:47 UTC Major SRX210 Chassis Fan Failure
Related Topics Monitoring the SRX210 Services Gateway Components Using LEDs on page 120
Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions on
page 122
Monitoring the SRX210 Services Gateway Power System on page 125
Maintaining the SRX210 Services Gateway Hardware Components on page 115
Juniper Networks Technical Assistance Center on page 128
Monitoring the SRX210 Services Gateway Chassis Using the CLI 119
Chapter 18: Monitoring the SRX210 Services Gateway