Network Router User Manual
NOTE: The values given in the usb0 rows provide information for USB level debugging.
This information is about USB hub topology.
show chassis environment
user@host > show chassis environment
Class Item Status Measurement
Temp Routing Engine OK 33 degrees C / 91 degrees F
Fans SRX210 Chassis fan OK Spinning at intermediate-speed
Power Power Supply 0 OK
show chassis fpc
user@host > show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online -------------------- CPU less FPC --------------------
1 Online -------------------- CPU less FPC --------------------
show chassis alarms
user@host > show chassis alarms
Alarm time Class Description
2009-05-11 10:47:47 UTC Major SRX210 Chassis Fan Failure
Related Topics ■ Monitoring the SRX210 Services Gateway Components Using LEDs on page 120
■ Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions on
page 122
■ Monitoring the SRX210 Services Gateway Power System on page 125
■ Maintaining the SRX210 Services Gateway Hardware Components on page 115
■ Juniper Networks Technical Assistance Center on page 128
Monitoring the SRX210 Services Gateway Chassis Using the CLI ■ 119
Chapter 18: Monitoring the SRX210 Services Gateway