Network Router User Manual

For more information on the show chassis alarms command, see the JUNOS Software
Administration Guide.
Table 44 on page 123 describes alarms that can occur for an SRX210 Services Gateway
chassis component.
Table 44: SRX210 Services Gateway Chassis Alarm Conditions and Corrective Actions
Alarm
SeverityActionAlarm ConditionComponent
Amber
(minor)
If the internal flash fails at startup, the
services gateway automatically boots
from the alternative boot device (USB
storage device).
NOTE: If you configured your services
gateway to boot from an alternative boot
device, ignore this alarm condition.
Reformat the internal flash and install a
bootable image. (See the JUNOS Software
Administration Guide.)
If you did not configure the services
gateway to boot from an alternative boot
device, contact Juniper Networks
Technical Assistance Center (JTAC). See
Juniper Networks Technical Assistance
Center on page 128.
The services
gateway boots from
an alternate boot
device.
Boot media
Red
(major)
Contact the Juniper Networks Technical
Assistance Center (JTAC). See Juniper
Networks Technical Assistance Center
on page 128.
If you must replace the failed Mini-PIM,
see the SRX Series Services Gateways for
the Branch Physical Interface Modules
Hardware Guide for information about
replacing the Mini-PIMs.
A Mini-PIM has
failed.
Mini-Physical
Interface
Module
(Mini-PIM)
Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions 123
Chapter 18: Monitoring the SRX210 Services Gateway