To install the WLA532E on a suspended ceiling rail using the legacy mounting bracket
adapter:
1. Remove the WLA522 from the installed mounted position by unlocking the universal
mounting bracket from the access point by inserting the lock/unlock tool into the
Unlock hole (see Figure 18 on page 58).
NOTE: Usea small-pointed instrument or a paperclip to unlock the access
point. Do not use a screwdriver as it can cause damage to the access point
lock mechanism or electronic components. Do not use excessive force
when using the tool to lock or unlock the universal mounting bracket.
Figure 18: Unlocking the Universal Mounting Bracket
2. Remove the WLA522 from the universal mounting bracket by pulling the access point
forward. See
3. Remove the Category 5e cable from the WLA522. The universal mounting bracket is
now exposed in a locked position on the ceiling T-bar. See Figure 19 on page 58
Figure 19: The Exposed WLA522 Universal Mounting Bracket on the Ceiling
T-bar
4. Ensure that two M3 pan head threaded mounting screws are installed on the bracket
to provide earthquake safety standards qualification. See Figure 20 on page 59 for
the mounting screws location on the universal mounting bracket.
Copyright © 2012, Juniper Networks, Inc.58
WLA532E Access Point Hardware Documentation