SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Published: 2012-06-11 Copyright © 2012, Juniper Networks, Inc.
Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright © 1986-1997, Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain.
http://www.juniper.net/support/eula.html. By downloading, installing or using such software, you agree to the terms and conditions of that EULA. Copyright © 2012, Juniper Networks, Inc.
iv Copyright © 2012, Juniper Networks, Inc.
Table of Contents About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Removing a Mini-Physical Interface Module from the SRX Series Services Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Replacing a Gigabit-Backplane Physical Interface Module in the SRX Series Services Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents Chapter 5 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module . . . . . . . . . . . . 49 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Overview . . . . . . . . . 49 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Network Interface Specifications . . . . . . . . . . . . . . .
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Chapter 9 1-Port T1/E1 Mini-Physical Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . 81 1-Port T1/E1 Mini-Physical Interface Module Overview . . . . . . . . . . . . . . . . . . . . . . 81 1-Port T1/E1 Mini-Physical Interface Module Hardware Specifications . . . . . . . . . 82 1-Port T1/E1 Mini-Physical Interface Module Network Interface Specifications . .
Table of Contents Chapter 13 8-Port Serial GPIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 8-Port Serial GPIM Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 8-Port Serial GPIM Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 8-Port Serial GPIM Network Interface Specifications . . . . . . . . . . . . . . . . . . . . . . 121 8-Port Serial GPIM Key Features . . . . . . .
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Quad CT1/E1 GPIM Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Quad CT1/E1 GPIM Basic Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Using the J-Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Using the CLI to Configure the CT1 Interface . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents Standard RJ-45 Cable Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 8-Port Serial Gigabit-Backplane Physical Interface Module Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide xii Copyright © 2012, Juniper Networks, Inc.
About This Guide • Objectives on page xiii • Audience on page xiii • Documentation Conventions on page xiii • SRX Series Documentation and Release Notes on page xv • Obtaining Documentation on page xv • Documentation Feedback on page xvi • Requesting Technical Support on page xvi Objectives This guide describes hardware components and installation, basic configuration, and basic troubleshooting procedures for the Juniper Networks SRX Series Services Gateway interfaces.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 1: Notice Icons Icon Meaning Description Informational note Indicates important features or instructions. Caution Indicates a situation that might result in loss of data or hardware damage. Warning Alerts you to the risk of personal injury or death. Laser warning Alerts you to the risk of personal injury from a laser. Table 2 on page xiv defines the text and syntax conventions used in this guide.
About This Guide Table 2: Text and Syntax Conventions (continued) Convention Description Examples | (pipe symbol) Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity. broadcast | multicast # (pound sign) Indicates a comment specified on the same line as the configuration statement to which it applies.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Documentation Feedback We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can send your comments to techpubs-comments@juniper.net, or fill out the documentation feedback form at http://www.juniper.net/techpubs/docbug/docbugreport.html.
About This Guide • Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/ • Open a case online in the CSC Case Manager: http://www.juniper.net/cm/ To verify service entitlement by product serial number, use our Serial Number Entitlement (SNE) Tool located at https://tools.juniper.net/SerialNumberEntitlementSearch/. Opening a Case with JTAC You can open a case with JTAC on the Web or by telephone. • Use the Case Manager tool in the CSC at http://www.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide xviii Copyright © 2012, Juniper Networks, Inc.
PART 1 SRX Series Services Gateway Interface Overview • Introduction to the SRX Series Services Gateway Interfaces on page 3 • Installing and Removing Interfaces on the SRX Series Services Gateway on page 17 Copyright © 2012, Juniper Networks, Inc.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 2 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 1 Introduction to the SRX Series Services Gateway Interfaces This chapter includes the following topics: • SRX Series Services Gateway Interface Overview on page 3 • SRX Series Services Gateway Mini-Physical Interface Modules Overview on page 4 • SRX Series Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 5 • Supported SRX Series Services Gateway Interfaces on page 7 • SRX Series Services Gateway Interfaces Models and Compatibility on page 8 • MTU Default an
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • SRX Series Services Gateway Mini-Physical Interface Modules Overview on page 4 • SRX Series Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 5 • Supported SRX Series Services Gateway Interfaces on page 7 SRX Series Services Gateway Mini-Physical Interface Modules Overview A Mini-Physical Interface Module (Mini-PIM) is a network interface card (NIC) that is insta
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces • SRX Series Services Gateway Interfaces Power and Heat Requirements on page 11 • SRX Series Services Gateways Interfaces Port Naming Conventions on page 13 SRX Series Services Gateway Gigabit-Backplane Physical Interface Modules Overview A Gigabit-Backplane Physical Interface Module (GPIM) is a network interface card (NIC) that installs in the front slots of the SRX550 or SRX650 Services Gateway to provide physical connections to a
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 4: SRX Series Services Gateway GPIM and XPIM Model Numbers GPIM or XPIM Model Number Dual CT1/E1 GPIM SRX-GP-DUAL-T1-E1 Quad CT1/E1 GPIM SRX-GP-QUAD-T1-E1 1-Port Clear Channel DS3/E3 GPIM SRX-GP-1DS3-E3 2-Port 10 Gigabit Ethernet XPIM SRX-GP-2XE-SFPP-TX 8-Port Serial GPIM SRX-GP-8SERIAL 16-Port Gigabit Ethernet XPIM 16-Port Gigabit Ethernet XPIM (with PoE) SRX-GP-16GE SRX-GP-16GE-POE 24-Port Gigabit Et
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces g032721 Figure 3: Example of a Standard GPIM (Installs in One Standard Slot) g032723 Figure 4: Example of a Double-High, Single-Wide XPIM g032724 Figure 5: Example of a Double-High, Double-Wide XPIM Related Documentation • Required Tools and Parts for Replacing a Gigabit-Backplane Physical Interface Module on page 22 • Removing a Blank Gigabit-Backplane Physical Interface Module Faceplate from the SRX Series Services Gateway on
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • T1/E1 • VDSL2 The SRX Series Services Gateways support the following Gigabit-Backplane Physical Interface Modules (GPIMs/XPIMs): Related Documentation • Dual CT1/E1 GPIM • Quad CT1/E1 GPIM • 1-Port Clear Channel DS3/E3 GPIM • 2-Port 10 Gigabit Ethernet XPIM • 8-Port Serial GPIM • 16-Port Gigabit Ethernet XPIM (with PoE) • 24-Port Gigabit Ethernet XPIM (with PoE) • SRX Series Services Gateway Mini-Ph
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces Table 5: Mini-PIM Types and Hardware Platform Compatibility (continued) Supported Platforms and Minimum Supported Junos OS Release Name SRX210 SRX220 SRX240 SRX550 G.SHDSL Junos OS Release 10.0 Junos OS Release 10.3 Junos OS Release 10.0 Junos OS Release 12.1 Serial Junos OS Release 9.5 Junos OS Release 10.3 Junos OS Release 9.5 Junos OS Release 12.1 T1/E1 Junos OS Release 9.4 Junos OS Release 10.3 Junos OS Release 9.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • SRX Series Services Gateway Gigabit-Backplane Physical Interface Modules Overview on page 5 • Supported SRX Series Services Gateway Interfaces on page 7 • SRX Series Services Gateway Interfaces Power and Heat Requirements on page 11 MTU Default and Maximum Values for Physical Interface Modules Table 7 on page 10 lists maximum transmission unit (MTU) values for the SRX Series Services Gateways Physical Interface Mo
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces Table 7: MTU Values for the SRX Series Services Gateways PIMs (continued) Physical Interface MTU (Bytes) Logical Interface MTU (Bytes) Default MTU (Bytes) Maximum MTU (Bytes) 1-Port Clear Channel DS3/E3 1504 1500 1504 9192 2-Port 10 Gigabit Ethernet XPIM 1514 1500 1514 9192 16-Port Gigabit Ethernet XPIM 1514 Unspecified 1514 Unspecified 24-Port Gigabit Ethernet XPIM 1514 Unspecified 1514 Unspecified PIM Related D
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 8: PIM Power Consumption Values (continued) Related Documentation PIM Model Power Consumption (Watts) Dual CT1/E1 GPIM 16.81 Quad CT1/E1 GPIM 16.81 8-Port Serial GPIM 13.1 1-Port Clear Channel DS3/E3 GPIM 22.
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces Table 9: SRX550 and SRX650 Services Gateway PoE Specifications Power Management Schemes Values Supported standards • IEEE 802.3 af • IEEE 802.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide For SRX Series Services Gateways, pim equals 0 for the port-naming convention. Table 10 on page 14 lists the typical interface types and interface numbers. Table 10: SRX Series Services Gateway Interface Port Number Examples Interface Type Interface Number Example ATM-over-ADSL at-1/0/0 G.
Chapter 1: Introduction to the SRX Series Services Gateway Interfaces Table 10: SRX Series Services Gateway Interface Port Number Examples (continued) Interface Type Interface Number Example 2-Port 10 Gigabit Ethernet XPIM • SRX550 Services Gateway—xe-3/0/0 • SRX650 Services Gateway—xe-2/0/0, xe-2/0/1, or xe-6/0/0, xe-6/0/1 NOTE: Represents two fiber and two copper ports; user configured.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 16 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 2 Installing and Removing Interfaces on the SRX Series Services Gateway This chapter includes the following topics: • Replacing a Mini-Physical Interface Module in the SRX Series Services Gateway on page 17 • Replacing a Gigabit-Backplane Physical Interface Module in the SRX Series Services Gateway on page 22 Replacing a Mini-Physical Interface Module in the SRX Series Services Gateway This topic includes the following sections: • Required Tools and Parts for Replacing a Mini-Physical Interfac
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • Removing a Mini-Physical Interface Module from the SRX Series Services Gateway on page 20 • SRX Series Services Gateway Mini-Physical Interface Modules Overview on page 4 Removing a Blank Mini-Physical Interface Module Faceplate from the SRX Series Services Gateway To maintain proper airflow through the services gateway, a blank faceplate should cover any empty Mini-Physical Interface Module (Mini-PIM) slot.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway Related Documentation • Required Tools and Parts for Replacing a Mini-Physical Interface Module on page 17 • Installing a Mini-Physical Interface Module in the SRX Series Services Gateway on page 19 • Removing a Mini-Physical Interface Module from the SRX Series Services Gateway on page 20 • SRX Series Services Gateway Mini-Physical Interface Modules Overview on page 4 Installing a Mini-Physical Interface Module in th
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Figure 7: Installing a Mini-PIM in an SRX Series Services Gateway 7. Using a 1/8-in. (3-mm) flat-blade (–) screwdriver, tighten the screws on each side of the Mini-PIM faceplate. 8. Insert the appropriate cables into the cable connectors on the Mini-PIM. 9.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway To remove a Mini-PIM from the SRX Series Services Gateway: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface on which you intend to place the Mini-PIM. 2. Attach an ESD grounding strap to your bare wrist, and connect the strap to the grounding point on the back of the device. 3. Unplug the power adapter from the device. Verify that the Power LED is off. 4.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Replacing a Gigabit-Backplane Physical Interface Module in the SRX Series Services Gateway This topic includes the following sections: • Required Tools and Parts for Replacing a Gigabit-Backplane Physical Interface Module on page 22 • Preventing Electrostatic Discharge Damage to the SRX Series Services Gateway on page 23 • Removing a Blank Gigabit-Backplane Physical Interface Module Faceplate from the SRX Series Serv
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway Preventing Electrostatic Discharge Damage to the SRX Series Services Gateway Many services gateway hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Removing a Blank Gigabit-Backplane Physical Interface Module Faceplate from the SRX Series Services Gateway To maintain proper airflow through the services gateway, leave blank faceplates in place over slots that do not contain Gigabit-Backplane Physical Interface Modules (GPIMs). Do not remove a blank faceplate unless you are installing a GPIM in the empty slot. To remove a blank faceplate: 1.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway NOTE: To maintain proper airflow through the services gateway, leave blank faceplates in place over slots that do not contain GPIMs. Do not remove a blank faceplate unless you are installing a GPIM in the empty slot. If you need to remove a blank faceplate to install the new GPIM into this slot, see “Removing a Blank Gigabit-Backplane Physical Interface Module Faceplate from the SRX Series Services Gateway” on page 24.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 5. Insert the appropriate cables into the cable connectors on the GPIM. 6. If necessary, arrange the cables to prevent them from dislodging or developing stress points: • Secure the cable so that it is not supporting its own weight as it hangs to the floor. • Place excess cable out of the way in a neatly coiled loop. • Use fasteners to maintain the shape of the cable loops.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway Installing a Double-High, Double-Wide Gigabit-Backplane Physical Interface Module on the SRX Series Services Gateway CAUTION: Only SRX650 Services Gateway supports hot-swappable functionality for GPIMs. Ensure that the GPIM is installed in the appropriate GPIM slot. For more information about the appropriate GPIM slots, see “SRX Series Services Gateway Gigabit-Backplane Physical Interface Modules Overview” on page 5.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Figure 12: GPIM Slot Bracket g032722 650 4. To continue with the GPIM installation, see “Installing a Gigabit-Backplane Physical Interface Module on the SRX Series Services Gateway” on page 24. CAUTION: If you remove a double-high, double-wide GPIM, you should replace the bracket before you install blank faceplates or other GPIMs. This is important for maintaining radio frequency compliance.
Chapter 2: Installing and Removing Interfaces on the SRX Series Services Gateway To remove a GPIM from the SRX Series Services Gateway: Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see “Preventing Electrostatic Discharge Damage to the SRX Series Services Gateway” on page 23. 1. 2. Push the OFFLINE button to turn the GPIM offline.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 7. Grasp the handles on each side of the GPIM faceplate, and slide the GPIM out of the services gateway. 8. Place the GPIM in an electrostatic bag or on an antistatic mat. 9. If you are not reinstalling a GPIM into an empty slot, install a blank GPIM faceplate over the empty slot to maintain proper airflow.
PART 2 Mini-Physical Interface Modules Supported on the SRX Series Services Gateway • 1-Port ADSL2+ Mini-Physical Interface Module on page 33 • 1-Port DOCSIS Mini-Physical Interface Module on page 41 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module on page 49 • 1-Port G.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 32 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 3 1-Port ADSL2+ Mini-Physical Interface Module This chapter includes the following topics: • 1-Port ADSL2+ Mini-Physical Interface Module Overview on page 33 • 1-Port ADSL2+ Mini-Physical Interface Module Hardware Specifications on page 34 • 1-Port ADSL2+ Mini-Physical Interface Module Network Interface Specifications on page 35 • 1-Port ADSL2+ Mini-Physical Interface Module Supported Standards on page 36 • 1-Port ADSL2+ Mini-Physical Interface Module Key Features on page 37 • 1-Port ADS
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide g031134 Figure 14: ADSL2+ Annex A Mini-PIM Front Panel Figure 15 on page 34 shows the ADSL2+ Annex B Mini-PIM front panel.
Chapter 3: 1-Port ADSL2+ Mini-Physical Interface Module Table 14: 1-Port ADSL2+ Mini-PIM Specifications (continued) Related Documentation Description Value Storage temperature –40°F through 158°F (–40°C through 70°C) Relative humidity 5% to 90% noncondensing • 1-Port ADSL2+ Mini-Physical Interface Module Overview on page 33 • 1-Port ADSL2+ Mini-Physical Interface Module Network Interface Specifications on page 35 • 1-Port ADSL2+ Mini-Physical Interface Module Supported Standards on page 36 •
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 15: 1-Port ADSL2+ Mini-PIM Network Interface Specifications (continued) Specifications Values Supported maximum speed • For ANSI DMT, 8 Mbps downstream and 896 Kbps upstream • For G.992.1, 8 Mbps downstream and 1.2 Mbps upstream • For G.992.3, 12 Mbps (Annex A) or 10 Mbps (Annex B) downstream and 1.2 Mbps Upstream • For G.992.5, 24 Mbps downstream and 1.
Chapter 3: 1-Port ADSL2+ Mini-Physical Interface Module • 1-Port ADSL2+ Mini-Physical Interface Module Key Features on page 37 • 1-Port ADSL2+ Mini-Physical Interface Module LEDs on page 37 • 1-Port ADSL2+ Mini-Physical Interface Module Supported Loopback Diagnostics on page 38 • 1-Port ADSL2+ Mini-Physical Interface Module Basic Configuration on page 39 1-Port ADSL2+ Mini-Physical Interface Module Key Features The 1-Port ADSL2+ Mini-Physical Interface Module (Mini-PIM) provides the following key f
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 16: 1-Port ADSL2+ Mini-PIM LED States LED Color State Description SYNC Green On Indicates that the ADSL interface is trained Blinking Indicates training is in progress Off Indicates that the interface is idle Blinking Indicates that traffic is passing through Off Indicates that no traffic is passing through TX/RX Related Documentation Green • 1-Port ADSL2+ Mini-Physical Interface Module Overview
Chapter 3: 1-Port ADSL2+ Mini-Physical Interface Module • 1-Port ADSL2+ Mini-Physical Interface Module Basic Configuration on page 39 1-Port ADSL2+ Mini-Physical Interface Module Basic Configuration To enable the 1-Port ADSL2+ Mini-Physical Interface Module (Mini-PIM) installed on the SRX Series Services Gateway, you must configure its properties.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Using the CLI To perform basic configuration for the 1-Port ADSL2+ Mini-PIM and to configure network interfaces for the services gateway with the CLI: • Verify that the serial interface is installed on the device: show chassis hardware • Verify the status of the interface: show interfaces terse • Assign the port an IP address: set interfaces at-1/0/0 unit 0 family inet address interface address/destination prefix •
CHAPTER 4 1-Port DOCSIS Mini-Physical Interface Module This chapter includes the following topics: • 1-Port DOCSIS Mini-Physical Interface Module Overview on page 41 • 1-Port DOCSIS Mini-Physical Interface Module Key Features on page 42 • 1-Port DOCSIS Mini-Physical Interface Module Supported Standards on page 43 • 1-Port DOCSIS Mini-Physical Interface Module Network Interface Specifications on page 43 • 1-Port DOCSIS Mini-Physical Interface Module Hardware Specifications on page 44 • 1-Port DOC
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide NOTE: (För Sverige och Norge endast) - Att ansluta en enhet via en jordad kontakt och/eller via annan utrustning samtidigt som den är kopplad till ett kabel-tv system innebär en brandrisk. För att förebygga detta måste du placera en galvanisk isolator mellan enheten och kabel-tv systemet.
Chapter 4: 1-Port DOCSIS Mini-Physical Interface Module • 1-Port DOCSIS Mini-Physical Interface Module Basic Configuration on page 46 1-Port DOCSIS Mini-Physical Interface Module Supported Standards The Data over Cable System Interface Specifications Mini-Physical Interface Module (1-Port DOCSIS Mini-PIM) supports DOCSIS 3.0 standards. NOTE: Ensure that your cable modem service provider has approved the use of 1-Port DOCSIS 3.0 Mini-PIM in your network.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 17: 1-Port DOCSIS Mini-PIM Network Interface Properties (continued) Related Documentation Specifications Downstream Upstream Operating level range -15 to +15 dBmV A-TDMA +8 to +54 dBmV (32 QAM, 64 QAM); +8 to +55 dBmV (8 QAM, 16 QAM); +8 to +58 dBmV (QPSK); S-CDMA +8 to +53 dBmV (all modulations) Input impedance 75Ω (nominal) 75Ω (nominal) Frequency range 108 to 1002 MHz (edge to edge) 5 to 42 MHz (US)
Chapter 4: 1-Port DOCSIS Mini-Physical Interface Module Related Documentation • 1-Port DOCSIS Mini-Physical Interface Module Overview on page 41 • 1-Port DOCSIS Mini-Physical Interface Module Key Features on page 42 • 1-Port DOCSIS Mini-Physical Interface Module Supported Standards on page 43 • 1-Port DOCSIS Mini-Physical Interface Module Network Interface Specifications on page 43 • 1-Port DOCSIS Mini-Physical Interface Module LEDs on page 45 • 1-Port DOCSIS Mini-Physical Interface Module Basi
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 19: 1-Port DOCSIS Mini-PIM LEDs States (continued) LED Color State Description UT Green Blinking The 1-Port DOCSIS Mini-PIM scans for a valid upstream DOCSIS channel to lock onto an upstream channel. On The 1-Port DOCSIS Mini-PIM has locked onto the DOCSIS upstream channel. Blinking The 1-Port DOCSIS Mini-PIM has an active link with the CPE device, but data communication is not taking place.
Chapter 4: 1-Port DOCSIS Mini-Physical Interface Module Using the J-Web Interface To perform basic configuration for the 1-Port DOCSIS Mini-PIM and to configure network interfaces for the services gateway using the J-Web interface: 1. In the J-Web interface, select Configure>Interfaces>Ports. The Interfaces page displays and lists the network interfaces present on the services gateway, along with configuration information (if configured). 2.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • Assign the port an IP address: set interfaces cm-1/0/0 unit 0 family inet address interface address/destination prefix • Add or select a security zone; for example, Trust: set security zones security-zone trust interfaces cm-1/0/0.
CHAPTER 5 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module This chapter includes the following topics: • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Overview on page 49 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Hardware Specifications on page 50 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Network Interface Specifications on page 51 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Supported Modules on page 51 • 1-Port Gigabit
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Hardware Specifications on page 50 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Key Features on page 53 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Network Interface Specifications on page 51 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Supported Modules on page 51 • 1-Port Gigabit
Chapter 5: 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Network Interface Specifications Table 21 on page 51 gives the network interface specifications of the 1-Port Gigabit Ethernet Small Form-Factor Pluggable Mini-Physical Interface Module (SFP Mini-PIM).
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 22: Supported 1-Port Gigabit Ethernet SFP Mini-Physical Interface Modules Juniper Product Number Connector Type (SFP Transceiver) Cable JX-SFP-1FE-FX 100BASE-FX LC JX-SFP-1GE-LH 1000BASE-LH (ZX) LC JX-SFP-1GE-LX 1000BASE-LX LC JX-SFP-1GE-SX 1000BASE-SX LC JX-SFP-1GE-T Tri-Rate 10/100/1000BASE-T, Copper Transceiver CAT-5e SFP-GE10KT13R14 1000BASE-BX10, at 10 km (TX1310 nm / RX1490 nm) LC SFP-GE10
Chapter 5: 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Hardware Specifications on page 50 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Network Interface Specifications on page 51 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Key Features on page 53 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module LEDs on page 54 • 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Basic Co
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module LEDs The 1-Port Gigabit Ethernet Small Form-Factor Pluggable Mini-Physical Interface Module (SFP Mini-PIM) has two LEDs located to the right of the socket. Table 23 on page 54 describes the LED states.
Chapter 5: 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module Using the J-Web Interface To perform basic configuration of the 1-Port Gigabit Ethernet SFP Mini-PIM and to configure network interfaces for the services gateway using the J-Web interface: 1. In the J-Web interface, select Configure>Interfaces>Ports. The Interfaces page is displayed and lists the network interfaces present on the services gateway, along with configuration information (if the device is configured). 2.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide NOTE: The configuration settings given in the following steps are an example. The actual configuration settings might vary depending on your requirements.
Chapter 5: 1-Port Gigabit Ethernet SFP Mini-Physical Interface Module set security zones security-zone trust interfaces ge-1/0/0.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 58 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 6 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module This chapter includes the following topics: • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Overview on page 59 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Supported Standards on page 60 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Operating Modes on page 60 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Key Features on page 61 • 1-Port G.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Supported Standards on page 60 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Operating Modes on page 60 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Key Features on page 61 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Hardware Specifications on page 62 • 1-Port G.
Chapter 6: 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module • Annex F • Annex G NOTE: All the annexes supported on the 1-Port G.SHDSL 8-Wire Mini-PIM can operate in 2-wire, 4-wire, and 8-wire modes. Table 24 on page 61 lists the 1-Port G.SHDSL 8-Wire Mini-PIM data rates for the different operating modes. Table 24: 1-Port G.SHDSL 8-Wire Mini-PIM Data Rates Annexes Operating Modes Data Rates (Mbps) Annex A and Annex B 2-wire (4 port 2-wire) 2.3 (maximum) 4-wire (2 port 4-wire) 4.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • ATM Operation, Administration, and Maintenance (OAM) support • Dying Gasp support Dying Gasp is the ability of the device to automatically notify the service provider digital subscriber line access multiplexer (DSLAM) if a power failure occurs. The customer premises equipment (CPE) sends a message to the DSLAM, which indicates that a line was lost because of loss in CPE power.
Chapter 6: 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Table 25: 1-Port G.SHDSL 8-Wire Mini-PIM Physical Specifications (continued) Related Documentation Description Value Storage temperature –40°F through 158°F (–40°C through 70°C) Relative humidity 5% to 90% noncondensing • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Overview on page 59 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Supported Standards on page 60 • 1-Port G.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Modules Basic Configuration on page 64 1-Port G.SHDSL 8-Wire Mini-Physical Interface Modules Basic Configuration To enable the 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module (Mini-PIM) installed on the SRX Series Services Gateway, you must configure its properties. You can perform the same configuration tasks using either the J-Web interface or the CLI.
Chapter 6: 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Using the CLI To perform basic configuration for the 1-Port G.SHDSL 8-Wire Mini-PIM and to configure network interfaces for the services gateway with the CLI: • Verify that the G.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 66 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 7 1-Port Serial Mini-Physical Interface Module This chapter includes the following topics: • 1-Port Serial Mini-Physical Interface Module Overview on page 67 • 1-Port Serial Mini-Physical Interface Module Hardware Specifications on page 68 • 1-Port Serial Mini-Physical Interface Module Supported Standards on page 68 • 1-Port Serial Mini-Physical Interface Module Key Features on page 69 • 1-Port Serial Mini-Physical Interface Module LEDs on page 69 • 1-Port Serial Mini-Physical Interface
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 1-Port Serial Mini-Physical Interface Module Basic Configuration on page 70 1-Port Serial Mini-Physical Interface Module Hardware Specifications Table 27 on page 68 gives the physical specifications of the 1-Port Serial Mini-Physical Interface Module (Mini-PIM). Table 27: 1-Port Serial Mini-PIM Physical Specifications Related Documentation Description Value Dimensions (H x W x L) 0.8 in. x 3.75 in. x 5.9 in. (2.
Chapter 7: 1-Port Serial Mini-Physical Interface Module 1-Port Serial Mini-Physical Interface Module Key Features The 1-Port Serial Mini-Physical Interface Module (Mini-PIM) provides the following key features: Related Documentation • Autoselection of operational modes based on DTE or DCE cables • Local and remote loopback diagnostics • Configurable clock rate for the transmit (TX) clock and receive (RX) clock • Complete configuration and management by using the CLI and the J-Web interface • 1-P
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide The device to which you are connecting and the serial interface types determine which type of cable you need. Table 29: Juniper Networks Serial Cables Related Documentation Product Number Interface Type Length Connector Type JX-CBL-EIA530-DCE EIA530 cable (DCE) 3.04 m (10 ft) Female JX-CBL-EIA530-DTE EIA530 cable (DTE) 3.04 m (10 ft) Male JX-CBL-RS232-DCE RS232 cable (DCE) 3.
Chapter 7: 1-Port Serial Mini-Physical Interface Module Using the J-Web Interface To perform basic configuration of the 1-Port Serial Mini-PIM and to configure network interfaces for the services gateway using the J-Web interface: 1. In the J-Web interface, select Configure>Interfaces>Ports. The Interfaces page displays and lists the network interfaces present on the services gateway, along with configuration information (if configured). 2.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide set interfaces se-1/0/0 unit 0 family inet address interface address/destination prefix • Add or select a security zone; for example, Trust: set security zones security-zone trust interfaces se-1/0/0.0 host-inbound-traffic system-services all • Add or select security zones for host inbound traffic protocol options: set security zones security-zone trust interfaces se-1/0/0.
CHAPTER 8 1-Port SFP Mini-Physical Interface Module This chapter includes the following topics: • 1-Port SFP Mini-Physical Interface Module Overview on page 73 • 1-Port SFP Mini-Physical Interface Module Hardware Specifications on page 74 • 1-Port SFP Mini-Physical Interface Module Network Interface Specifications on page 74 • 1-Port SFP Mini-Physical Interface Module Supported Modules on page 75 • 1-Port SFP Mini-Physical Interface Module Key Features on page 76 • 1-Port SFP Mini-Physical Inter
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 1-Port SFP Mini-Physical Interface Module Hardware Specifications Table 30 on page 74 gives the physical specifications of the 1-Port Small Form-Factor Pluggable Mini-Physical Interface Module (SFP Mini-PIM). Table 30: 1-Port SFP Mini-PIM Physical Specifications Related Documentation Description Value Dimensions (H x W x L) 0.80 in. x 3.75 in. x 5.9 in. (2.0 cm x 9.5 cm x 14.5 cm ) Weight 3.
Chapter 8: 1-Port SFP Mini-Physical Interface Module • 1-Port SFP Mini-Physical Interface Module Supported Modules on page 75 • 1-Port SFP Mini-Physical Interface Module Key Features on page 76 • 1-Port SFP Mini-Physical Interface Module LEDs on page 77 • 1-Port SFP Mini-Physical Interface Module Basic Configuration on page 78 1-Port SFP Mini-Physical Interface Module Supported Modules You can customize the Ethernet interface type by using different one-port small form-factor pluggable (SFP) module
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 32: 1-Port SFP Mini-Physical Interface Modules (continued) Product Number Interface Type Connector SFP-GE40KT15R13 1000BASE-BX, at 40 km (TX1550 nm / RX1310 nm) LC EX-SFP-FE20KT13R15 100Base-BX Fast Ethernet Optics, at 20 km (TX 1310 nm / RX 1550 nm) LC EX-SFP-FE20KT15R13 100Base-BX Fast Ethernet Optics, at 20 km (TX 1550 nm / RX 1310 nm) LC NOTE: We strongly recommend the use of Juniper Networks SFP and
Chapter 8: 1-Port SFP Mini-Physical Interface Module • 1000BASE-LH (ZX) • Tri-Rate 10/100/1000BASE-T, Copper Transceiver • 1000BASE-BX10, at 10 km (TX1310 nm / RX1490 nm) • 1000BASE-BX10, at 10 km (TX1310 nm / RX1550 nm) • 1000BASE-BX10, at 10 km (TX1490 nm / RX1310 nm) • 1000BASE-BX10, at 10 km (TX1550 nm / RX1310 nm) • 1000BASE-BX, at 40 km (TX1310 nm / 1550 nm) • 1000BASE-BX, at 40km (TX1550 LC nm / RX1310 nm) • 100Base-BX Fast Ethernet Optics, at 20 km (TX 1310 nm / RX 1550 nm) • 100
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 33: 1-Port SFP Mini-PIM LED States LED Color State Description LINK Green On Port is online Off Port is offline Blinking Port is receiving or sending data Off Port might be on but is not receiving or sending data ACT Related Documentation Green • 1-Port SFP Mini-Physical Interface Module Overview on page 73 • 1-Port SFP Mini-Physical Interface Module Hardware Specifications on page 74 • 1-Port
Chapter 8: 1-Port SFP Mini-Physical Interface Module 3. To use the port on the Mini-PIM, you must assign it to a security zone other than the Null zone. Optionally, you can also assign the port an IP address (for example, 192.168.3.1/24). Enter or select the following settings: a. Select Configure>Security>Zones/Screens. b. Add or select a security zone other than Null; for example, Trust. c. For host inbound traffic, set the following: • Services=Allow All • Protocols=Allow All d.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide set security policies default-policy permit-all Related Documentation 80 • 1-Port SFP Mini-Physical Interface Module Overview on page 73 • 1-Port SFP Mini-Physical Interface Module Hardware Specifications on page 74 • 1-Port SFP Mini-Physical Interface Module Network Interface Specifications on page 74 • 1-Port SFP Mini-Physical Interface Module Supported Modules on page 75 • 1-Port SFP Mini-Physical Interface
CHAPTER 9 1-Port T1/E1 Mini-Physical Interface Module This chapter includes the following topics: • 1-Port T1/E1 Mini-Physical Interface Module Overview on page 81 • 1-Port T1/E1 Mini-Physical Interface Module Hardware Specifications on page 82 • 1-Port T1/E1 Mini-Physical Interface Module Network Interface Specifications on page 82 • 1-Port T1/E1 Mini-Physical Interface Module Supported Standards on page 83 • 1-Port T1/E1 Mini-Physical Interface Module Key Features on page 84 • 1-Port T1/E1 Min
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 1-Port T1/E1 Mini-Physical Interface Module Supported Loopback Diagnostics on page 85 • 1-Port T1/E1 Mini-Physical Interface Module Basic Configuration on page 86 1-Port T1/E1 Mini-Physical Interface Module Hardware Specifications Table 34 on page 82 gives the physical specifications of the 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM).
Chapter 9: 1-Port T1/E1 Mini-Physical Interface Module Table 35: 1-Port T1/E1 Mini-PIM Network Interface Specifications (continued) Specification T1 Specification E1 Specifications Transmit bit rate 1.544 Mbps 2.048 Mbps Receive bit rate 1.544 Mbps 2.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • AT&T Pub 54014 • ITU G.751, G.
Chapter 9: 1-Port T1/E1 Mini-Physical Interface Module Table 36: 1-Port T1/E1 Mini-PIM LED States LED Color State Description ALARM Yellow On Indicates that there is a local or remote alarm; device has detected a failure. Off Indicates that there are no alarms or failures. On Indicates that a loopback or line state is detected. Off Indicates that the loopback is not active. On Indicates that the Mini-PIM link is up. Off Indicates that carrier detect is not active.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • PRBS 2^11-1 (as specified in ITU-T O.153)/2047 pattern • PRBS 2^15-1 (as specified in ITU-T O.151/O.153) • PRBS 2^20-1 (as specified in ITU-T O.
Chapter 9: 1-Port T1/E1 Mini-Physical Interface Module c. For host inbound traffic, set the following: • System Services=Allow All • Protocols=Allow All d. Click OK to save changes, and click Commit to apply the configuration and other pending changes (if any). 4. To use the port on the Mini-PIM, you must also set security policies. Select the following settings: a. Select Configure>Security>Policy>Apply Policy. b. Set Policy Action: Default Policy Action=Permit-All. c.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide set security zones security-zone trust interfaces t1-1/0/0.0 host-inbound-traffic protocols all For E1 interfaces: set security zones security-zone trust interfaces e1-1/0/0.
CHAPTER 10 1-Port VDSL2 (Annex A) Mini-Physical Interface Module This chapter includes the following topics: • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Overview on page 89 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Key Features on page 90 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Supported Profiles on page 91 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Hardware Specifications on page 91 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module LEDs
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide g031104 Figure 23: VDSL2 Annex A Mini-PIM Related Documentation • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Key Features on page 90 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Supported Profiles on page 91 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module LEDs on page 92 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Hardware Specifications on page 91 • 1-Port VDSL2 (Anne
Chapter 10: 1-Port VDSL2 (Annex A) Mini-Physical Interface Module • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Cable Specifications on page 192 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Basic Configuration on page 93 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Supported Profiles A profile is a table that contains a list of preconfigured VDSL2 settings.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 38: 1-Port VDSL2 (Annex A) Mini-PIM Hardware Specifications Related Documentation Description Value Dimensions (H x W x L) 3.75 in. x 5.9 in. x 0.80 in. (9.5 cm x 14.5 cm x 2.0 cm) Weight 4.
Chapter 10: 1-Port VDSL2 (Annex A) Mini-Physical Interface Module • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Hardware Specifications on page 91 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Cable Specifications on page 192 • 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Basic Configuration on page 93 1-Port VDSL2 (Annex A) Mini-Physical Interface Module Basic Configuration To enable the 1-Port VDSL2 (Annex A) Mini-Physical Interface Module (Mini-PIM) installed on the SR
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide c. Click OK to save changes, and click Commit to apply the configuration and other pending changes (if any). For more information, in the J-Web interface, select Configure>Interfaces and click Help.
PART 3 Gigabit-Backplane Physical Interface Modules Supported on the SRX Series Services Gateway • 1-Port Clear Channel DS3/E3 GPIM on page 97 • 2-Port 10 Gigabit Ethernet XPIM on page 109 • 8-Port Serial GPIM on page 119 • 16-Port Gigabit Ethernet XPIM on page 131 • 24-Port Gigabit Ethernet XPIM on page 139 • Dual CT1/E1 GPIM on page 149 • Quad CT1/E1 GPIM on page 157 Copyright © 2012, Juniper Networks, Inc.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 96 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 11 1-Port Clear Channel DS3/E3 GPIM This chapter includes the following topics: • 1-Port Clear Channel DS3/E3 GPIM Overview on page 97 • 1-Port Clear Channel DS3/E3 GPIM Hardware Specifications on page 98 • 1-Port Clear Channel DS3/E3 GPIM Network Interface Specifications on page 99 • 1-Port Clear Channel DS3/E3 GPIM Supported Standards on page 101 • 1-Port Clear Channel DS3/E3 GPIM Key Features on page 101 • 1-Port Clear Channel DS3/E3 GPIM LEDs on page 102 • 1-Port Clear Channel DS3/
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide The 1-Port Clear Channel DS3/E3 GPIM can be plugged into any GPIM slot on the services gateway. Figure 24 on page 98 shows the 1-Port Clear Channel DS3/E3 GPIM front panel. g032741 Figure 24: 1-Port Clear Channel DS3/E3 GPIM Front Panel NOTE: Only SRX650 Services Gateway supports hot-swappable functionality for GPIMs.
Chapter 11: 1-Port Clear Channel DS3/E3 GPIM Table 40: 1-Port Clear Channel DS3/E3 GPIM Hardware Specifications (continued) Related Documentation Description Value Relative humidity 5% to 90% noncondensing Altitude Up to 10,000 ft (3,000 m) • 1-Port Clear Channel DS3/E3 GPIM Overview on page 97 • 1-Port Clear Channel DS3/E3 GPIM Network Interface Specifications on page 99 • 1-Port Clear Channel DS3/E3 GPIM Supported Standards on page 101 • 1-Port Clear Channel DS3/E3 GPIM Key Features on pag
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 41: 1-Port Clear Channel DS3/E3 GPIM Network Interface Specifications (continued) Description DS3 Mode E3 Mode Network alarms Supported in accordance with the ANSI specification: Supported in accordance with the ITU-T specification: • Loss of Signal (LOS) • LOS • Out of Frame (OOF) • OOF • Loss of Frame (LOF) • AIS • Alarm Identification Signal (AIS) • RDI • Phase Locked Loop (PLL) • Error c
Chapter 11: 1-Port Clear Channel DS3/E3 GPIM • 1-Port Clear Channel DS3/E3 GPIM Components on page 103 • 1-Port Clear Channel DS3/E3 GPIM Supported Loopback Diagnostics on page 104 • 1-Port Clear Channel DS3/E3 GPIM Basic Configuration on page 105 1-Port Clear Channel DS3/E3 GPIM Supported Standards The 1-Port Clear Channel DS3/E3 Gigabit-Backplane Physical Interface Module (GPIM) supports the following standards: • • Related Documentation DS3 mode standards: • ANSI TI.102, TI.107, T1.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • Support for chassis clusters • Support for anti-counterfeit check • Loopback (local, remote, and payload) and BERT, PRBS, and QRSS diagnostics support • Support for generation and detection of loopback control codes (line-loopback activate and deactivate) and FEAC codes • Maximum transmission unit (MTU) size of 4474 bytes (default) and 9192 bytes (maximum) • 1-Port Clear Channel DS3/E3
Chapter 11: 1-Port Clear Channel DS3/E3 GPIM Table 42: 1-Port Clear Channel DS3/E3 GPIM LED States (continued) LED Color State Description RDI Amber On Port is receiving remote defect indication (RDI) alarm. ALARM Green On There are no alarms or defects. Red On An alarm or a defect is present. Amber On Out-of-frame (OOF) RX multi-frame is not aligned.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 43: 1-Port Clear Channel DS3/E3 GPIM Components (continued) Related Documentation Component Location Description TX and RX coaxial connectors Middle/right of the GPIM Dual female 75-ohm BNC coaxial connectors: TX (transmit) and RX (receive). Captive screws One on each side of the GPIM Use the captive screws to hold the GPIM in place.
Chapter 11: 1-Port Clear Channel DS3/E3 GPIM • • PRBS 2^31-1 • QRSS 2^20-1 (as specified in ITU-T 0.151) BERT results should be in the following form: • Received bit count • Received error count In conformance with ANSI T1.107-1995, the 1-Port Clear Channel DS3/E3 GPIM supports both generation and detection of FEAC codes, as well as line-loopback activate and deactivate control codes.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide FPC 5 FPC 6 PIC 0 FPC 7 FPC 8 PIC 0 Power Supply 0 • REV 10 REV 10 750-023810 750-023808 AABE1433 AAAJ9355 REV 10 REV 09 750-023808 750-023810 AAAV0753 AAAC6572 Rev 03 740-024283 UE05105 FPC FPC 4x CT1E1 gPIM FPC FPC 1x CLR CH T3/E3 PS 645W AC Verify the FPC status of the interface: show chassis fpc root@srx650r03> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt D
Chapter 11: 1-Port Clear Channel DS3/E3 GPIM set interfaces t3-3/0/0 encapsulation cisco-hdlc • Add or select a security zone; for example, trust: set security zones security-zone trust interfaces t3-3/0/0.0 host-inbound-traffic system-services all • Add or select security zones for host inbound traffic: set security zones security-zone trust interfaces t3-3/0/0.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 108 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 12 2-Port 10 Gigabit Ethernet XPIM This chapter includes the following topics: • 2-Port 10 Gigabit Ethernet XPIM Overview on page 109 • 2-Port 10 Gigabit Ethernet XPIM Key Features on page 110 • 2-Port 10 Gigabit Ethernet XPIM Hardware Specifications on page 111 • 2-Port 10 Gigabit Ethernet XPIM LEDs on page 113 • 2-Port 10 Gigabit Ethernet XPIM Components on page 114 • 2-Port 10 Gigabit Ethernet XPIM Basic Configuration on page 115 2-Port 10 Gigabit Ethernet XPIM Overview The 2-Port 10
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide The 2-Port 10 Gigabit Ethernet XPIM contains two 10 Gigabit Ethernet interfaces with both copper and small form-factor pluggable plus transceiver (SFP+) terminations, to support redundancy and enable the services gateway ateway to be used as a pure security service device. The 2-Port 10 Gigabit Ethernet XPIM also provides effective MPLS/GRE termination of customer traffic with reasonable performance.
Chapter 12: 2-Port 10 Gigabit Ethernet XPIM • Copper Twin-AX 3m • Copper Twin-AX 5m • Copper Twin-AX 7m • Anti-counterfeit capabilities. • Quad speed support for copper mode: 10GBase-T IEEE 820.3an, 1000Base-T IEEE 802.3ab, 100Base-T IEEE 802.3u, and 10Base-T IEEE 802.3. • Standard quality of service (QoS) features. • User-configuration of fiber and copper ports: • When the interface is configured as a copper port, typical Ethernet configuration such as autonegotiation is supported.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 44: 2-Port 10 Gigabit Ethernet XPIM Hardware Specifications Description Value Dimensions (H x W x L) .78 in. H x 6.72 in. W x 8.01 in. L (1.98 cm x 17.08 cm x 20.57 cm) Weight 18.6 oz (.
Chapter 12: 2-Port 10 Gigabit Ethernet XPIM 2-Port 10 Gigabit Ethernet XPIM LEDs The 2-Port 10 Gigabit Ethernet XPIM has the LEDs listed in Table 45 on page 113. Table 45: 2-Port 10 Gigabit Ethernet XPIM LED States LED Color State Description STATUS Green On XPIM is online and functioning normally. Amber On XPIM is starting up, running diagnostics, or shutting down. Red On XPIM has failed. Off XPIM has no power and can be pulled out safely. On Port is online. Off Port is offline.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 2-Port 10 Gigabit Ethernet XPIM Components on page 114 • 2-Port 10 Gigabit Ethernet XPIM Basic Configuration on page 115 2-Port 10 Gigabit Ethernet XPIM Components The 2-Port 10 Gigabit Ethernet XPIM contains the components listed in Table 46 on page 114.
Chapter 12: 2-Port 10 Gigabit Ethernet XPIM NOTE: We strongly recommend the use of Juniper Networks SFP/SFP+ and XFP transceivers. We cannot guarantee correct operation if other transceivers are used. The transceiver type can be different in each port, as long as a supported part number is used.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide the J-Web interface, the Point and Click CLI, or the CLI. In addition, you can configure a wide variety of options that are not encountered frequently.
Chapter 12: 2-Port 10 Gigabit Ethernet XPIM Using the Point and Click CLI to Set Interface Mode and Speed Options To set the interface mode and speed options for the 2-Port 10 Gigabit Ethernet XPIM with the Point and Click CLI: 1. From the J-Web interface main menu, select Configure>CLI Tools>CLI Tools>Point and Click CLI. 2. Next to Interfaces, click Configure or Edit. The Interfaces page displays. 3. Click the Interface name or click Edit. The details page for the specified interface appears. 4.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide NOTE: The interface xe-6/0/0 is the correct configuration if the 2-Port 10 Gigabit Ethernet XPIM is installed in slot 6. If the 2-Port 10 Gigabit Ethernet XPIM is installed in slot 2 (valid only on SRX650), then the correct interface configuration would be xe-2/0/0 • Assign MTU values: set interfaces xe-6/0/0 unit 0 family inet mtu mtu values • Set link options: set interfaces xe-6/0/0 gigether-options802.
CHAPTER 13 8-Port Serial GPIM • 8-Port Serial GPIM Overview on page 119 • 8-Port Serial GPIM Hardware Specifications on page 120 • 8-Port Serial GPIM Network Interface Specifications on page 121 • 8-Port Serial GPIM Key Features on page 122 • 8-Port Serial GPIM LEDs on page 123 • 8-Port Serial GPIM Components on page 123 • 8-Port Serial GPIM Interface Cables on page 124 • 8-Port Serial GPIM Basic Configuration on page 126 8-Port Serial GPIM Overview The 8-Port Serial Gigabit-Backplane Physi
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • 8-Port Serial GPIM Hardware Specifications on page 120 • 8-Port Serial GPIM Components on page 123 • 8-Port Serial GPIM Key Features on page 122 • 8-Port Serial GPIM LEDs on page 123 • 8-Port Serial GPIM Interface Cables on page 124 • 8-Port Serial GPIM Network Interface Specifications on page 121 • 8-Port Serial GPIM Basic Configuration on page 126 8-Port Serial GPIM Hardware Specif
Chapter 13: 8-Port Serial GPIM • 8-Port Serial GPIM Basic Configuration on page 126 8-Port Serial GPIM Network Interface Specifications Table 49 on page 121 lists the network interface specifications of the 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM). Table 49: 8-Port Serial GPIM Network Interface Specifications Description Specification Network Interface Specifications Line encoding NRZ and NRZI Line Protocols • EIA-530 • EIA-530A • EIA-449 • RS-232 • V.35 • X.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 8-Port Serial GPIM Components on page 123 • 8-Port Serial GPIM Key Features on page 122 • 8-Port Serial GPIM LEDs on page 123 • 8-Port Serial GPIM Interface Cables on page 124 • 8-Port Serial GPIM Basic Configuration on page 126 8-Port Serial GPIM Key Features The 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM) provides the following key features: Related Documentation 122 • Autoselection
Chapter 13: 8-Port Serial GPIM 8-Port Serial GPIM LEDs Table 50 on page 123 lists the LEDs of the 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM). Table 50: 8-Port Serial GPIM LED States LED Color State Description STATUS Green On GPIM is online and functioning normally. Amber On GPIM is starting up, running diagnostics, or shutting down. Red On GPIM has failed. Off GPIM has no power and can be removed safely. Yellow On An alarm is present.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 51: 8-Port Serial GPIM Components Component Location Description ONLINE/OFFLINE button Right side of the GPIM To gracefully shut down the GPIM (if the Services and Routing Engine is on), press down and hold the button for 4 to 5 seconds and then release. The GPIM gracefully shuts down and turns off the power supply units (PSUs). Only SRX650 Services Gateway supports hot-swappable functionality for GPIMs.
Chapter 13: 8-Port Serial GPIM GPIM. The device to which you are connecting and the serial interface types determine which type of cable you need. Table 52: Juniper Networks Supported Cables Product Number Interface Type Letter Connector Type SRX-CBL-RS232-DTE-2 RS-232 cable (DTE) C Male SRX-CBL-RS232-DCE-2 RS-232 cable (DCE) D Female SRX-CBL-V35-DTE-2 V.35 cable (DTE) E Male SRX-CBL-V35-DCE-2 V.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 8-Port Serial GPIM Components on page 123 • 8-Port Serial GPIM Key Features on page 122 • 8-Port Serial GPIM LEDs on page 123 • 8-Port Serial GPIM Network Interface Specifications on page 121 • 8-Port Serial GPIM Basic Configuration on page 126 8-Port Serial GPIM Basic Configuration The 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM) is a network interface card (NIC) that installs in the front
Chapter 13: 8-Port Serial GPIM To configure the 8-Port Serial GPIM and configure a network interface on the GPIM: 1.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Device flags : Present Running Interface flags: Point-To-Point Internal: 0x0 Link flags : Keepalives Hold-times : Up 0 ms, Down 0 ms CoS queues : 8 supported, 8 maximum usable queues Last flapped : 2012-03-01 11:07:13 PST (10:57:02 ago) Statistics last cleared: Never Traffic statistics: Input bytes : 0 0 bps Output bytes : 0 0 bps Input packets: 0 0 pps Output packets: 0 0 pps Input errors: Errors: 3, Drops: 0, Framing er
Chapter 13: 8-Port Serial GPIM user@host# set security zones security-zone zone-name interfaces interface-name host-inbound-traffic protocols all 7.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 130 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 14 16-Port Gigabit Ethernet XPIM This chapter includes the following topics: • 16-Port Gigabit Ethernet XPIM Overview on page 131 • 16-Port Gigabit Ethernet XPIM Key Features on page 132 • 16-Port Gigabit Ethernet XPIM Hardware Specifications on page 133 • 16-Port Gigabit Ethernet XPIM LEDs on page 133 • 16-Port Gigabit Ethernet XPIM Components on page 135 • 16-Port Gigabit Ethernet XPIM Basic Configuration on page 136 16-Port Gigabit Ethernet XPIM Overview The 16-Port Gigabit Ethernet
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide g032725 Figure 31: 16-Port Gigabit Ethernet XPIM g032726 Figure 32: 16-Port Gigabit Ethernet with PoE XPIM Related Documentation • 16-Port Gigabit Ethernet XPIM Key Features on page 132 • 16-Port Gigabit Ethernet XPIM Hardware Specifications on page 133 • 16-Port Gigabit Ethernet XPIM LEDs on page 133 • 16-Port Gigabit Ethernet XPIM Components on page 135 • 16-Port Gigabit Ethernet XPIM Basic Configuration o
Chapter 14: 16-Port Gigabit Ethernet XPIM • 16-Port Gigabit Ethernet XPIM Basic Configuration on page 136 16-Port Gigabit Ethernet XPIM Hardware Specifications The 16-Port Gigabit Ethernet XPIM has the specifications listed in Table 53 on page 133. Table 53: 16-Port Gigabit Ethernet XPIM Hardware Specifications Related Documentation Description Value Dimensions (H x W x L) 1.58 in. H x 6.72 in. W x 8.5 in. L (4.0 cm x 17.1 cm x 21.6 cm) Weight 16.5 oz (0.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 54: 16-Port Gigabit Ethernet XPIM LED States (continued) LED Color State Description LINK/ACT Green On Port is online. Off Port is offline. Blinking Port is receiving or sending data. N/A N/A Not used on the non-PoE XPIM. Green On Port is PoE enabled and online. Off Port is offline. Blinking Port is PoE enabled and receiving or sending data.
Chapter 14: 16-Port Gigabit Ethernet XPIM • Power over Ethernet Support on SRX Series Services Gateway Interfaces on page 12 16-Port Gigabit Ethernet XPIM Components The 16-Port Gigabit Ethernet XPIM contains the components listed in Table 55 on page 135. Table 55: 16-Port Gigabit Ethernet XPIM Components Component Location Description XPIM ONLINE/OFFLINE button Right side of the XPIM Use the XPIM ONLINE/OFFLINE button to gracefully shut down the XPIM.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 16-Port Gigabit Ethernet XPIM Basic Configuration To enable the 16-Port Gigabit Ethernet XPIM installed on the SRX Series Services Gateway, you must configure its properties. You can perform the same configuration tasks using either the J-Web interface or the CLI. In addition, you can configure a wide variety of options that are not encountered frequently.
Chapter 14: 16-Port Gigabit Ethernet XPIM Using the CLI To perform basic configuration for the 16-Port Gigabit Ethernet XPIM and to configure network interfaces for the services gateway with the CLI: • Verify that the 16-Port Gigabit Ethernet XPIM is installed on the services gateway: show chassis hardware • Verify the FPC status of the interface: show chassis fpc • Assign the port an IP address: set interfaces ge-1/0/0 unit 0 family inet address interface address/destination prefix • Assign MTU val
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 138 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 15 24-Port Gigabit Ethernet XPIM This chapter includes the following topics: • 24-Port Gigabit Ethernet XPIM Overview on page 139 • 24-Port Gigabit Ethernet XPIM Key Features on page 140 • 24-Port Gigabit Ethernet XPIM Hardware Specifications on page 141 • 24-Port Gigabit Ethernet XPIM LEDs on page 142 • 24-Port Gigabit Ethernet XPIM Components on page 143 • 24-Port Gigabit Ethernet XPIM Basic Configuration on page 145 24-Port Gigabit Ethernet XPIM Overview The 24-Port Gigabit Ethernet
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide NOTE: Only SRX650 Services Gateway supports hot-swappable functionality for GPIMs. Figure 35 on page 140 shows the 24-Port Gigabit Ethernet XPIM, and Figure 36 on page 140 shows the 24-Port Gigabit Ethernet XPIM with PoE.
Chapter 15: 24-Port Gigabit Ethernet XPIM Related Documentation • 24-Port Gigabit Ethernet XPIM Overview on page 139 • 24-Port Gigabit Ethernet XPIM Hardware Specifications on page 141 • 24-Port Gigabit Ethernet XPIM LEDs on page 142 • 24-Port Gigabit Ethernet XPIM Components on page 143 • 24-Port Gigabit Ethernet XPIM Basic Configuration on page 145 24-Port Gigabit Ethernet XPIM Hardware Specifications The 24-Port Gigabit Ethernet XPIM has the hardware specifications listed in Table 57 on page
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • 24-Port Gigabit Ethernet XPIM Key Features on page 140 • 24-Port Gigabit Ethernet XPIM LEDs on page 142 • 24-Port Gigabit Ethernet XPIM Components on page 143 • 24-Port Gigabit Ethernet XPIM Basic Configuration on page 145 24-Port Gigabit Ethernet XPIM LEDs The 24-Port Gigabit Ethernet XPIM has the LEDs listed in Table 58 on page 142.
Chapter 15: 24-Port Gigabit Ethernet XPIM g032727 Figure 37: 24-Port Gigabit Ethernet XPIM g032728 Figure 38: 24-Port Gigabit Ethernet XPIM with PoE Related Documentation • 24-Port Gigabit Ethernet XPIM Overview on page 139 • 24-Port Gigabit Ethernet XPIM Key Features on page 140 • 24-Port Gigabit Ethernet XPIM Hardware Specifications on page 141 • 24-Port Gigabit Ethernet XPIM Components on page 143 • 24-Port Gigabit Ethernet XPIM Basic Configuration on page 145 • Power over Ethernet Suppo
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 59: 24-Port Gigabit Ethernet XPIM Components (continued) Component Location Description 24 fixed Gigabit Ethernet ports labeled 0–23 Middle of the XPIM NOTE: Each port on the 24-Port Gigabit Ethernet with PoE XPIM supports Power over Ethernet (PoE). NOTE: The 24-Port Gigabit Ethernet with PoE XPIM port labels are yellow instead of white.
Chapter 15: 24-Port Gigabit Ethernet XPIM Table 60: 24-Port Gigabit Ethernet XPIM SFP Transceivers Related Documentation Product Number Interface Type Connector JX-SFP-FE-FX 100Base-FX Fast Ethernet optical transceiver SFP LC JX-SFP-1GE-LH 1000Base-LH Gigabit Ethernet optical transceiver SFP, 80 Km reach LC JX-SFP-1GE-LX 1000Base-LX Gigabit Ethernet optical transceiver SFP LC JX-SFP-1GE-SX 1000Base-SX Gigabit Ethernet optical transceiver SFP, 550 m reach without DDM (Difference in the Depth
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide tasks using either the J-Web interface or the CLI. In addition, you can configure a wide variety of options that are not encountered frequently. NOTE: When installing the 24-Port Gigabit Ethernet XPIM, which uses four slots, you must install it in the 20-Gigabit GPIM slots 2 and 6, which refer to the bottom four slots 1 to 4, or the top four slots 5 to 8.
Chapter 15: 24-Port Gigabit Ethernet XPIM Using the CLI To perform basic configuration for the 24-Port Gigabit Ethernet XPIM and to configure network interfaces for the services gateway with the CLI: • Verify that the 24-Port Gigabit Ethernet XPIM is installed on the services gateway: show chassis hardware • Verify the FPC status of the interface: show chassis fpc • Assign the port an IP address: set interfaces ge-2/0/0 unit 0 family inet address interface address/destination prefix • Assign MTU val
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 148 Copyright © 2012, Juniper Networks, Inc.
CHAPTER 16 Dual CT1/E1 GPIM This chapter includes the following topics: • Dual CT1/E1 GPIM Overview on page 149 • Dual CT1/E1 GPIM Key Features on page 150 • Dual CT1/E1 GPIM Network Interface Specifications on page 151 • Dual CT1/E1 GPIM Hardware Specifications on page 151 • Dual CT1/E1 GPIM LEDs on page 152 • Dual CT1/E1 GPIM Components on page 153 • Dual CT1/E1 GPIM Basic Configuration on page 153 Dual CT1/E1 GPIM Overview A Gigabit-Backplane Physical Interface Module (GPIM) is a network i
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Figure 39: Dual CT1/E1 GPIM Related Documentation • Dual CT1/E1 GPIM Key Features on page 150 • Dual CT1/E1 GPIM Network Interface Specifications on page 151 • Dual CT1/E1 GPIM Hardware Specifications on page 151 • Dual CT1/E1 GPIM LEDs on page 152 • Dual CT1/E1 GPIM Components on page 153 • Dual CT1/E1 GPIM Basic Configuration on page 153 • Installing a Gigabit-Backplane Physical Interface Module on the SR
Chapter 16: Dual CT1/E1 GPIM Dual CT1/E1 GPIM Network Interface Specifications The Dual CT1/E1 Gigabit-Backplane Physical Interface Module (GPIM) provides the network interface specifications specific to T1 or E1 modes, listed in Table 61 on page 151.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 62: Dual CT1/E1 GPIM Hardware Specifications Related Documentation Description Value Dimensions (H x W x L) 0.78 in. H x 6.72 in. W x 8.1 in. L (19.8 mm x 170.8 mm x 205.7 mm) Weight 15.4 oz (0.
Chapter 16: Dual CT1/E1 GPIM • Dual CT1/E1 GPIM Hardware Specifications on page 151 • Dual CT1/E1 GPIM Components on page 153 • Dual CT1/E1 GPIM Basic Configuration on page 153 Dual CT1/E1 GPIM Components The Dual CT1/E1 Gigabit-Backplane Physical Interface Module (GPIM) contains the components listed in Table 64 on page 153.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide the same configuration tasks using either the J-Web interface or the CLI. In addition, you can configure a wide variety of options that are not encountered frequently.
Chapter 16: Dual CT1/E1 GPIM c. Click OK to save changes, and click Commit to apply the configuration and other pending changes (if any). For advanced configuration information, see the Junos OS Network Interfaces Configuration Guide.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • Verify that the Dual CT1/E1 GPIM is installed on the services gateway: show chassis hardware • Verify the FPC status of the interface: show chassis fpc • Configure the parent CE1 interface with no partitioning: set interfaces ce1-3/0/0 no-partition interface-type e1 • Configure the child E1 interface and assign an IP address: set interfaces e1-3/0/0 unit 0 family inet address ip4–address/prefix • Assign MTU val
CHAPTER 17 Quad CT1/E1 GPIM This chapter includes the following topics: • Quad CT1/E1 GPIM Overview on page 157 • Quad CT1/E1 GPIM Key Features on page 158 • Quad CT1/E1 GPIM Network Interface Specifications on page 159 • Quad CT1/E1 GPIM Hardware Specifications on page 159 • Quad CT1/E1 GPIM LEDs on page 160 • Quad CT1/E1 GPIM Components on page 161 • Quad CT1/E1 GPIM Basic Configuration on page 161 Quad CT1/E1 GPIM Overview A Gigabit-Backplane Physical Interface Module (GPIM) is a network i
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide g032730 Figure 40: Quad CT1/E1 GPIM Related Documentation • Quad CT1/E1 GPIM Key Features on page 158 • Quad CT1/E1 GPIM Network Interface Specifications on page 159 • Quad CT1/E1 GPIM Hardware Specifications on page 159 • Quad CT1/E1 GPIM LEDs on page 160 • Quad CT1/E1 GPIM Components on page 161 • Quad CT1/E1 GPIM Basic Configuration on page 161 • Installing a Gigabit-Backplane Physical Interface Module
Chapter 17: Quad CT1/E1 GPIM Quad CT1/E1 GPIM Network Interface Specifications The Quad CT1/E1 Gigabit-Backplane Physical Interface Module (GPIM) provides the network interface specifications specific to T1 or E1 modes, listed in Table 65 on page 159.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 66: Quad CT1/E1 GPIM Hardware Specifications Related Documentation Description Value Dimensions (H x W x L) 0.78 in. H x 6.72 in. W x 8.1 in. L (19.8 mm x 170.8 mm x 205.7 mm) Weight 15.4 oz (0.
Chapter 17: Quad CT1/E1 GPIM • Quad CT1/E1 GPIM Components on page 161 • Quad CT1/E1 GPIM Basic Configuration on page 161 Quad CT1/E1 GPIM Components The Quad CT1/E1 Gigabit-Backplane Physical Interface Module (GPIM) contains the components listed in Table 68 on page 161. Table 68: Quad CT1/E1 GPIM Components Component Location Description GPIM ONLINE/OFFLINE button Right side of the GPIM Use the GPIM ONLINE/OFFLINE button to gracefully shut down the GPIM.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide the same configuration tasks using either the J-Web interface or the CLI. In addition, you can configure a wide variety of options that are not encountered frequently.
Chapter 17: Quad CT1/E1 GPIM c. Click OK to save changes, and click Commit to apply the configuration and other pending changes (if any). For advanced configuration information, see the Junos OS Network Interfaces Configuration Guide.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • Verify that the Quad CT1/E1 GPIM is installed on the services gateway: show chassis hardware • Verify the FPC status of the interface: show chassis fpc • Configure the parent CE1 interface with no partitioning: set interfaces ce1-1/0/0 no-partition interface-type e1 • Configure the child E1 interface and assign an IP address: set interfaces e1-1/0/0 unit 0 family inet address ip4–address/prefix • Assign MTU val
PART 4 Appendixes • SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts on page 167 • Contacting Customer Support and Returning SRX Series Services Gateway Hardware Components on page 235 Copyright © 2012, Juniper Networks, Inc.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 166 Copyright © 2012, Juniper Networks, Inc.
APPENDIX A SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts • 1-Port T1/E1 Mini-Physical Interface Module Cable Specifications on page 167 • 1-Port ADSL2+ Mini-Physical Interface Module Cable Specifications on page 171 • 1-Port Serial Mini-Physical Interface Module Cable Specifications on page 172 • 1-Port G.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 69 on page 168 gives RJ-48 connector to RJ-48 connector (straight) pinouts.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 70: RJ-48 Connector to RJ-48 Connector (Crossover) Pinouts (continued) Related Documentation RJ-48 Pin (on T1/E1 Mini-PIM) RJ-48 Pin (Data Numbering Form) Signal 3 3 Shield/Return/Ground 6 6 Shield/Return/Ground 7 No connect No connect 8 No connect No connect • RJ-48 Connector to RJ-48 Connector (Straight) Pinouts for the 1-Port T1/E1 Mini-Physical Interface Module on page 167 • RJ-48 Con
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 71: RJ-48 Connector to DB-15 Connector (Straight) Pinouts (continued) Related Documentation RJ-48 Pin (on T1/E1 Mini-PIM) DB-15 Pin (Data Numbering Form) Signal 10 No connect No connect 11 No connect No connect 12 No connect No connect 13 No connect No connect 14 No connect No connect 15 No connect No connect • RJ-48 Connector to RJ-48 Connector (Straight) Pinouts for the 1-Port T1/E1 Mini-Ph
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 72: RJ-48 Connector to DB-15 Connector (Crossover) Pinouts (continued) Related Documentation RJ-48 Pin (on T1/E1 Mini-PIM) DB-15 Pin (Data Numbering Form) Signal 8 No connect No connect 9 No connect No connect 10 No connect No connect 11 No connect No connect 12 No connect No connect 13 No connect No connect 14 No connect No connect 15 No connect No connect • RJ-48 Connector to
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 73: RJ-11 Connector Pinouts for the 1-Port ADSL2+ Mini-PIM (continued) Related Documentation Pin Signal 3 RJ P-Tip 4 RJ N-Ring 5 No connect 6 No connect • 1-Port ADSL2+ Mini-Physical Interface Module Overview on page 33 • 1-Port ADSL2+ Mini-Physical Interface Module Hardware Specifications on page 34 1-Port Serial Mini-Physical Interface Module Cable Specifications This topic includes the following s
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 74: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 15 1 - Shield Ground 1 2 2 Transmit Data (A) 60 3 59 Receive Data (A) 37 4 38 Request to Send (A) 48 5 47 Clear to Send (A) 33 6 - Data Set Ready (A) 57 7 - Signal Ground 13 8 14 Received Line Signal Detector (A) 51 9 52 Receive Clock (B) 14 10 13 Received L
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 74: EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) Related Documentation LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 30 to 29 - - - • EIA-530A DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 174 • RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 176 • RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physi
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 75: EIA-530A DTE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) Related Documentation LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 57 7 - Signal Ground 13 8 14 Received Line Signal Detector (A) 6 9 5 Receive Clock (B) 14 10 13 Received Line Signal Detector (B) 51 11 52 Terminal Timing (B) 55 12 56 Transmit Clock (B) 38 13 37 Clear to Send (B) 59 14 60 Transmi
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 177 • RS-422/449 (EIA-449) DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 178 • RS-422/449 (EIA-449) DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 180 • V.35 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 182 • V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 76: RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) Related Documentation LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 22 to 21 - - - • EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 172 • RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 177 • RS-422/449 (EIA-449) DCE Cable Pinouts for the 1-Po
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 77: RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) Related Documentation LFH-60 Pin DB-25 Pin LFH-60 Pairing Description 56 15 - Transmit Clock 5 17 - Receive Clock 41 18 - Local Loopback 33 20 - Data Terminal Ready 52 24 - Terminal Clock 22 to 21 - - - 18 to 17 - - - • EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 172
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 78: RS-422/449 DCE Cable Pinouts for the 1-Port Serial Mini-PIM LFH-60 Pin DC-37 (DB-37) Pin LFH-60 Pairing Description 15 1 - Shield Ground 1 4 2 Send Data (A) 56 5 55 Send Timing (A) 60 6 59 Receive Data (A) 37 7 38 Request to Send (A) 52 8 51 Receive Timing (A) 48 9 47 Clear to Send (A) 45 10 - Local Loopback 33 11 34 Data Mode (A) 9 12 10 Terminal Ready (A) 13
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 78: RS-422/449 DCE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) Related Documentation LFH-60 Pin DC-37 (DB-37) Pin LFH-60 Pairing Description 6 35 5 Terminal Timing (B) 57 37 - Send Common 26 to 25 - - - • EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 172 • EIA-530A DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on pag
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 79: RS-422/449 DTE Cable Pinouts for the 1-Port Serial Mini-PIM (continued) LFH-60 Pin DC-37 (DB-37) Pin LFH-60 Pairing Description 48 7 47 Request to Send (A) 5 8 6 Receive Timing (A) 37 9 38 Clear to Send (A) 41 10 - Local Loopback 9 11 10 Data Mode (A) 33 12 34 Terminal Ready (A) 13 13 14 Receive Ready (A) 52 17 51 Terminal Timing (A) 36 19 - Signal Ground 4 20 -
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 172 • EIA-530A DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 174 • RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 176 • RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 177 • RS-422/449 (EIA-449
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 80: V.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide V.35 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module Table 81 on page 184 describes the V.35 DTE cable pinouts. Table 81: V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Related Documentation • EIA-530A DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 172 • EIA-530A DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 174 • RS-232 DCE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 176 • RS-232 DTE Cable Pinouts for the 1-Port Serial Mini-Physical Interface Module on page 177 • RS-422/449
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 82: X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 83: X.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 1-Port G.SHDSL 8-Wire Mini-PIM Wire Modes The 1-Port G.SHDSL 8-wire Mini-Physical Interface Module (Mini-PIM) requires different combination of RJ-45 cables depending upon the connection available on the patch panel. Table 84 on page 188 lists the cables that you can order from Juniper Networks to connect the 1-Port G.SHDSL 8-Wire Mini-PIM. Table 84: 1-Port G.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Figure 42: G.SHDSL Mini-PIM Operating in 4X2-Wire Mode Figure 43 on page 189 shows the topology for G.SHDSL 8-Wire Mini-PIM operating in 1X8-wire mode. Figure 43: G.SHDSL Mini-PIM Operating in 1X8-Wire Mode RJ-45 Cable (RJ-45 to Four RJ-11 Connectors) Pin Assignment Table 85 on page 189 shows the pin assignments of the RJ-45 cable (RJ-45 to four RJ-11).
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 85: RJ-45 Cable (RJ-45 to Four RJ-11 Connectors) Pinout Details (continued) RJ-45 Pin Number Connections RJ-11 Pin Number Connections Plug Number 7 Tip 3 3 Tip 3 of 4th port P4 8 Ring 3 4 Ring 3 of 4th port Figure 44 on page 190 shows the RJ-45 cable design that connects to four RJ-11 cable connections.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 86: RJ-45 Cable (RJ-45 to Two RJ-11 Connectors) Pinout Details (continued) Signal Signal Signal RJ-11 Pin Number Plug 1 Plug 2 3 Tip 2 3 - Tip 2 of 2nd port 4 Tip 0 3 Tip 0 of 1st port - 5 Ring 0 4 Ring 0 of 1st port - 6 Ring 2 4 - Ring 2 of 2nd port 7 Tip 3 2 - Tip 3 of 2nd port 8 Ring 3 5 - Ring 3 of 2nd port RJ-45 Pin Number Figure 45 on page 191 shows the RJ-45 cable
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 87: Standard RJ-45 Cable Pinout Details Related Documentation RJ-45 Pin Number Connections 1 Tip 2 Ring 3 Tip 4 Tip 5 Ring 6 Ring 7 Tip 8 Ring • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Overview on page 59 • 1-Port G.SHDSL 8-Wire Mini-Physical Interface Module Supported Standards on page 60 • 1-Port G.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Figure 46: RJ-11 Cable Pinout for 1-Port VDSL2 (Annex A) Mini-PIM Table 88 on page 193 shows the pin assignments of the RJ-11 cable.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • EIA-530A DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 202 • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 206 • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 210 • EIA-530 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 214 • RS-2
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 89: EIA-449 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir Pair Pairing Description VHDCI-68 Pin DB-37 (1) Pin T4 8 O Pair 5 T2 Terminal Timing (A) T50 9 O Pair 6 T48 Request to Send (A) T8 10 I T49 11 O Pair 7 T47 Terminal Ready (A) T45 12 I Pair 8 T43 Data Mode (A) T46 13 O Pair 9 T44 Receive Ready (A) T38 17 I Pair 10 T36 Receive Timing (A) T33 1
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 89: EIA-449 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-37 (2) Pin Output (O) and Input (I) Pair Pairing Description VHDCI-68 Pin DB-37 (1) Pin T48 27 O Pair 6 T50 Request to Send (B) T47 29 O Pair 7 T59 Terminal Ready (B) T43 30 I Pair 8 T45 Data Mode (B) T44 31 O Pair 9 T46 Receiver Ready (B) T36 35 I Pair 10 T38 Receive Timing (B) T51 37 Shield Ground T
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 89: EIA-449 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-37 (2) Pin Output (O) and Input (I) T26 10 I T67 11 O Pair 7 T65 Terminal Ready (A) T63 12 I Pair 8 T61 Data Mode (A) T64 13 O Pair 9 T62 Receive Ready (A) T56 17 I Pair 10 T54 Receive Timing (A) T18 19 Shield Ground T24 20 Shield Ground T57 22 I Pair 1 T59 Receive Data (B) T23 23 O Pair 2
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 89: EIA-449 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-37 (2) Pin Output (O) and Input (I) Pair Pairing Description T61 30 I Pair 8 T63 Data Mode (B) T62 31 O Pair 9 T64 Receiver Ready (B) T54 35 I Pair 10 T56 Receive Timing (B) T27 37 VHDCI-68 Pin T29 to T27 Related Documentation 198 DB-37 (1) Pin Shield Ground Protocol Identifier_1 • EIA-449 DTE Cable Pinouts f
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts • X.21 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 229 EIA-449 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module Table 90 on page 199 gives the EIA-449 DTE cable pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM).
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 90: EIA-449 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir 200 DB-37 (2) Pin Output (O) and Input (I) Pair Pairing Description VHDCI-68 Pin DB-37 (1) Pin T39 24 I Pair 3 T41 Send Data (B) T48 25 O Pair 4 T50 Request to Send (B) T36 26 I Pair 5 T38 Receive Timing (B) T40 27 I Pair 6 T42 Clear to Send (B) T43 29 I Pair 7 T45 Data Mode (B) T47 30 O Pair 8 T49 Te
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 90: EIA-449 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-37 (2) Pin Output (O) and Input (I) Pair Pairing Description T63 11 I Pair 7 T61 Data Mode (A) T67 12 O Pair 8 T65 Terminal Ready (A) T64 13 I Pair 9 T62 Receive Ready (A) T22 17 O Pair 10 T20 Terminal Timing (A) T18 19 Shield Ground T24 20 Shield Ground T32 22 O Pair 1 T34 Send Data (B) T23
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • EIA-449 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 194 • EIA-530 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 214 • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 210 • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Modul
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 91: EIA-530A DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir Pair Pairing Description VHDCI-68 Pin DB-25 (1) Pin T42 4 I Pair 4 T40 Clear to Send (A) T50 5 O Pair 5 T48 Request to Send (A) T49 6 O T37 7 T46 8 O Pair 6 T44 Receive Ready (A) T2 9 O Pair 7 T4 Terminal Timing (B) T44 10 O Pair 6 T46 Receiver Ready (B) T36 11 I Pair 8 T38 Receive Timing (
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 91: EIA-530A DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir 204 VHDCI-68 Pin DB-25 (1) Pin T45 20 T51 23 T38 24 DB-25 (2) Pin Output (O) and Input (I) Pair Pairing I Description Data Mode (A) Shield Ground I Pair 8 T36 Receive Timing (A) T11 to T15 Protocol Identifier_1 T35 to T33 Protocol Identifier_2 T52 1 Shield Ground T59 2 I Pair 1 T57 Receive Data (A) T34 3 O P
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 91: EIA-530A DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T23 12 O Pair 2 T25 Send Timing (B) T66 13 O Pair 5 T68 Request to Send (B) T57 14 I Pair 1 T59 Receive Data (B) T25 15 O Pair 2 T23 Send Timing (A) T32 16 O Pair 3 T34 Send Data (B) T22 17 O Pair 7 T20 Terminal Timing (A) T26 18
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 210 • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 206 • RS-232 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 220 • RS-232 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 218 • V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 92: EIA-530A DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir Output (O) and Input (I) Pair Pairing Description 8 I Pair 6 T44 Receive Ready (A) T36 9 I Pair 7 T38 Receive Timing (B) T44 10 I Pair 6 T36 Receiver Ready (B) T2 11 O Pair 8 T4 Terminal Timing (B) T5 12 I Pair 2 T4 Send Timing (B) T40 13 I Pair 5 T42 Clear to Send (B) T14 14 O Pair 1 T16 Sen
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 92: EIA-530A DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir VHDCI-68 Pin DB-25 (1) Pin DB-25 (2) Pin Output (O) and Input (I) Pair Pairing T1 to T3 208 Description Protocol Mode T52 1 Shield Ground T34 2 O Pair 1 T32 Send Data (A) T59 3 I Pair 3 T57 Receive Data (A) T68 4 O Pair 4 T66 Clear to Send (A) T60 5 I Pair 5 T58 Data Mode (A) T63 6 I T18 7 T64 8 I P
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 92: EIA-530A DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T56 17 I Pair 7 T54 Receive Timing (A) T28 18 O T66 19 O T67 20 O T24 23 T22 24 VHDCI-68 Pin Related Documentation DB-25 (1) Pin Local Loopback Pair 4 T68 Request to Send (B) Terminal Ready (A) Shield Ground O Pair 8 T20 Terminal Timing (A
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • V.35 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 226 • V.35 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 222 • X.21 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 232 • X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 93: EIA-530 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description VHDCI-68 Pin DB-25 (1) Pin T44 10 O Pair 6 T46 Receiver Ready (B) T36 11 I Pair 8 T38 Receive Timing (B) T5 12 O Pair 9 T7 Send Timing (B) T48 13 O Pair 4 T50 Request to Send (B) T39 14 I Pair 1 T41 Receive Data (B) T7 15 O Pair 9 T
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 93: EIA-530 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir VHDCI-68 Pin 212 DB-25 (1) Pin DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T52 1 Shield Ground T59 2 I Pair 1 T57 Receive Data (A) T34 3 O Pair 2 T32 Send Data (A) T60 4 I Pair 3 T58 Clear to Send (A) T68 5 O Pair 4 T66 Request to Send (A) T67 6 O Pair 5 T65 Terminal Ready (A) T65 2
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 93: EIA-530 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T32 16 O Pair 2 T34 Send Data (B) T22 17 O Pair 7 T20 Terminal Timing (A) T26 18 I T58 19 I Pair 3 T60 Clear to Send (B) T63 20 I Pair 10 T61 Data Mode (A) T61 23 I Pair 10 T63 Data Mode (B) T56 24 I Pair 8 T54 Receive Timing (A)
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • V.35 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 226 • V.35 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 222 • X.21 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 232 • X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 94: EIA-530 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description VHDCI-68 Pin DB-25 (1) Pin T2 11 O Pair 8 T4 Terminal Timing (B) T5 12 I Pair 9 T7 Send Timing (B) T40 13 I Pair 4 T42 Clear to Send (B) T14 14 O Pair 1 T16 Send Data (B) T7 15 I Pair 9 T5 Send Timing (A) T39 16 I Pair 2 T41 Receiv
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 94: EIA-530 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir VHDCI-68 Pin 216 DB-25 (1) Pin DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T52 1 Shield Ground T34 2 O Pair 1 T32 Send Data (A) T59 3 I Pair 2 T57 Receive Data (A) T68 4 O Pair 3 T66 Request to Send (A) T60 5 I Pair 4 T58 Clear to Send (A) T63 6 I Pair 5 T61 Data Mode (A) T61 22 I
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 94: EIA-530 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Pair Pairing Description T57 16 I Pair 2 T59 Receive Data (B) T56 17 I Pair 7 T54 Receive Timing (A) T28 18 O T66 19 O Pair 3 T68 Request to Send (B) T67 20 O Pair 10 T65 Terminal Ready (A) T65 23 O Pair 10 T67 Terminal Ready (B) T22 24 O Pair 8 T20 Termi
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • RS-232 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 220 • RS-232 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 218 • V.35 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 226 • V.35 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 222 • X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 95: RS-232 DCE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Description VHDCI-68 Pin DB-25 (1) Pin T45 20 I Data Mode (A) T38 24 I Receive Timing (A) T13 to T12 T52 1 T59 2 I Receive Data (A) T34 3 O Send Data (A) T60 4 I Clear to Send (A) T68 5 O Request to Send (A) T67 6 O Terminal Ready (A) T55 7 T64 8 O Receive Re
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 210 • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 206 • EIA-530A DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 202 • RS-232 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 220 • V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 96: RS-232 DTE Cable Pinouts for the 8-Port Serial GPIM (continued) Dir DB-25 (2) Pin Output (O) and Input (I) Description VHDCI-68 Pin DB-25 (1) Pin T38 17 I Receive Timing (A) T10 18 O Local Loopback T49 20 O Terminal Ready (A) T4 24 O Terminal Timing (A) T13 to T12 Protocol Identifier_0 T1 to T3 Protocol Mode T52 1 Shield Ground T34 2 O Send Data (A) T59 3 I Receive Dat
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Related Documentation • EIA-449 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 199 • EIA-449 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 194 • EIA-530 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 214 • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 97: V.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 97: V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 97: V.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • X.21 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 232 • X.21 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 229 V.35 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module Table 98 on page 226 gives the V.35 DTE cable pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM). Table 98: V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 98: V.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 98: V.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 206 • EIA-530A DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 202 • RS-232 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 220 • RS-232 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 218 •
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Table 99: X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 99: X.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide X.21 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module Table 100 on page 232 gives the X.21 DTE cable pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module (GPIM). NOTE: For X.21 protocol, even if the cable is not connected to the other end, the LED status will show green. Table 100: X.
Appendix A: SRX Series Services Gateways Interface Cable Specifications and Connector Pinouts Table 100: X.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 234 • EIA-530 DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 214 • EIA-530 DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 210 • EIA-530A DTE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 206 • EIA-530A DCE Cable Pinouts for 8-Port Serial Gigabit-Backplane Physical Interface Module on page 202 •
APPENDIX B Contacting Customer Support and Returning SRX Series Services Gateway Hardware Components • Return Procedure for SRX Series Services Gateway Hardware Components on page 235 • Locating the SRX Series Services Gateway Hardware Component Mini-PIM or GPIM Serial Number Label on page 236 • Information You Might Need to Supply to JTAC on page 237 • Contacting Customer Support on page 237 • Packing the Hardware Components for Shipment on page 238 Return Procedure for SRX Series Services Gatew
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide For more information about return and repair policies, see the customer support Web page at http://www.juniper.net/support/guidelines.html. For product problems or technical support issues, open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (outside the United States).
Appendix B: Contacting Customer Support and Returning SRX Series Services Gateway Hardware Components Information You Might Need to Supply to JTAC If you are returning a hardware component to Juniper Networks for repair or replacement, obtain a Return Materials Authorization (RMA) number from Juniper Networks Technical Assistance Center (JTAC).
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide • Information You Might Need to Supply to JTAC on page 237 • Packing the Hardware Components for Shipment on page 238 Packing the Hardware Components for Shipment Follow these guidelines for packing and shipping individual components of the services gateway: • When you return a component, make sure that it is adequately protected with packing materials and packed so that the pieces are prevented from moving around in
PART 5 Index • Index on page 241 Copyright © 2012, Juniper Networks, Inc.
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 240 Copyright © 2012, Juniper Networks, Inc.
Index Symbols #, comments in configuration statements....................xv ( ), in syntax descriptions.....................................................xv 1-Port ADSL2+ Mini-PIM.......................................................33 basic configuration........................................................39 hardware specifications..............................................34 key features.......................................................................37 LED states...........................
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 1-Port VDSL2 (Annex A) Mini-PIM...................................89 Annex A.............................................................................89 basic configuration........................................................94 hardware specifications...............................................91 key features.....................................................................90 LEDs..............................
Index overview...........................................................................149 specifications..................................................................151 E E1 ports Dual CT1/E1 GPIM.........................................................149 Quad CT1/E1 GPIM.......................................................157 RJ-48 cable pinouts.....................................................167 E3 mode 1-Port Clear Channel DS3/E3 GPIM ......................
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide Juniper Networks Technical Assistance Center See JTAC JX-SFP-1000BASE-T............................................................75 JX-SFP-1FE-FX..................................................................52, 75 JX-SFP-1GE-LH...............................................................52, 145 JX-SFP-1GE-LX........................................................52, 75, 145 JX-SFP-1GE-SX...........................
Index RJ-48 pinouts Mini-PIM...........................................................................167 S Serial Mini-PIM overview.............................................................................67 serial number label, GPIM.................................................236 services gateway Mini-PIMs.............................................................................4 removing blank faceplates.........................................24 removing GPIMs...............................
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide 246 Copyright © 2012, Juniper Networks, Inc.