User guide

CHAPTER 11
Hardware Replacement
Replacing the Cooling Fans on page 43
Replacing a Hard Drive on page 44
Replacing IOC Modules on page 44
Replacing a Power Supply on page 46
Replacing the Cooling Fans
The SA 6500 ships with two cooling fans installed in the back of the chassis. If you need
to replace one of the cooling fans, you can “hot-swap” the faulty fan for a replacement
during operation in a matter of moments. You can purchase additional cooling fans from
your authorized Juniper reseller, or you can purchase them in the future to replace faulty
or failed cooling fans, as necessary.
To remove and install a cooling fan module:
1. To release the cooling fan module, do one of the following:
Press and slide the release trigger toward the center of the cooling fan module
Loosen the thumbscrews
2. Grasp the cooling fan module and carefully pull it out.
CAUTION: Once you remove the cooling fan module, it is important that
you replace it with a replacement cooling fan. The second fan is required
for proper air flow across the chassis’s internal components; it is not a
redundant fan.
3. Line the a cooling fan module up with an empty cooling fan port on the back of the
chassis.
4. Slowly slide the module into the chassis until it clicks into place.
5. If your cooling fan is equipped with thumb screws, tighten the screws.