Datasheet

5
Specifications
WX15 WX20 WX60 WX100 WX STACK
Performance
Total reduction throughput
speed
64 Kbps to 1 Mbps 64 Kbps to 2 Mbps 512 Kbps to 20 Mbps 1 Mbps to 20 Mbps 1 Mbps to 155 Mbps
IPsec throughput 1 Mbps 2 Mbps 15 Mbps 15 Mbps N/A
Tunnels supported Up to 6 with all
features enabled
Up to 10 with all
features enabled
Up to 110 with all
features enabled
Up to 105 with all
features enabled
Up to 660 with all
features enabled
Connections
Network interfaces Two copper fail-to-wire
10/100 Ethernet ports
Two copper fail-to-wire
10/100 Ethernet ports
Two copper fail-to-wire
10/100/1000 Ethernet
ports
Two copper
10/100/1000 fail-to-
wire Ethernet ports
or two fiber 1000
Ethernet ports
WX Stack includes 1
WX100 and up to 6 WX
Series clients (excluding
WX15s and WX20s)
Power
Power requirement 100-240 VAC,
50-60 Hz, 50 Watts
max or 170 BTU/hr
100-240 VAC,
50-60 Hz, 150 Watts
max or 510 BTU/hr
100-240 VAC,
50-60 Hz, 150 Watts
max or 510 BTU/hr
Dual 100-240 VAC,
50-60 Hz, 300 Watts
max or 1025 BTU/hr
Dimensions and Weight
(W x H x D) 15.3 x 1.8 x 9.1 in
(38.9 x 4.5 x 23 cm)
1 rack unit
17.1 x 1.8 x 14.3 in
(43.4 x 4.5 x 36.3 cm)
1 rack unit
17.1 x 3.4 x 16.7 in
(43.4 x 8.7 x 42.4 cm)
2 rack units
17.1 x 3.4 x 16.7 in
(43.4 x 8.7 x 42.4 cm)
2 rack units
Weight 4 lbs (1.8 kg) 19 lbs (8.6 kg) 20.2 lbs (9.2 kg) 30 lbs (13.6 kg)
Operating Environment
Temperature 41° to 104° F
(5° to 40° C)
41° to 104° F
(5° to 40° C)
41° to 104° F
(5° to 40° C)
41° to 104° F
(5° to 40° C)
Humidity 10% to 85%,
noncondensing at
95° F (35° C)
10% to 85%,
noncondensing at
95° F (35° C)
10% to 85%,
noncondensing at
95° F (35° C)
10% to 85%,
noncondensing at
95° F (35° C)
Maximum altitude 10,000  (3,048 m) 10,000  (3,048 m) 10,000  (3,048 m) 10,000  (3,048 m)
Non-operating Environment
Temperature -40° to 158° F
(-40° to 70° C)
-40° to 158° F
(-40° to 70° C)
-40° to 158° F
(-40° to 70° C)
-40° to 158° F
(-40° to 70° C)
Humidity 5% to 95%,
noncondensing at
95° F (35° C)
5% to 95%,
noncondensing at
95° F (35° C)
5% to 95%,
noncondensing at
95° F (35° C)
5% to 95%,
noncondensing at
95° F (35° C)
Maximum altitude 40,000  (12,192 m) 40,000  (12,192 m) 40,000  (12,192 m) 40,000  (12,192 m)
Regulations
Emissions FCC Class A, EN 55022
Class A, EN 55024
Immunity,
EN 61000-3-2, VCCI
Class A
FCC Class A, EN 55022
Class A, EN 55024
Immunity,
EN 61000-3-2, VCCI
Class A
FCC Class A, EN 55022
Class A, EN 55024
Immunity,
EN 61000-3-2, VCCI
Class A
FCC Class A, EN 55022
Class A, EN 55024
Immunity,
EN 61000-3-2, VCCI
Class A
Safety CAN/CSA-C22.2 No.
60950-1-03 - UL
60950-1 and
EN 60950-1
CAN/CSA-C22.2 No.
60950-1-03 - UL
60950-1 and
EN 60950-1
CAN/CSA-C22.2 No.
60950-1-03 - UL
60950-1 and
EN 60950-1
CAN/CSA-C22.2 No.
60950-1-03 - UL
60950-1 and
EN 60950-1
Acoustic noise Maximum noise level is
less than 70 dB
Maximum noise level is
less than 70 dB
Maximum noise level is
less than 70 dB
Maximum noise level is
less than 70 dB
Juniper Networks Services and Support