IT Libretto Istruzioni 2 GB Instruction Manual 11 FR Manuel d’Instructions DE Bedienungsanleitung 20 NL Gebruiksaanwijzing 38 29
Dear Customer, If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come.
RECOMMENDATIONS AND SUGGESTIONS INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. • The minimum safety distance between the cooker top and the extractor hood is 650 mm. • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. • For Class I appliances, check that the domestic power supply guarantees adequate earthing.
CHARACTERISTICS Dimensions 260 300 800 - 1130 670 200 163 898 25 0 20 520 Components 15 14.1 7.3 2.1 12a 7.2.1 12c 2 2.2 11 12a 11 Ref. 1 2 2.1 2.2 14.1 15 Q.ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 1 Telescopic Chimney comprising: 1 Upper Section 1 Lower Section 2 Air Outlet Connection Extension 1 Air Outlet Connection Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 7.
INSTALLATION 1÷2 Wall drilling and bracket fixing 650 min. 12a 116 116 395 11 X 7.2.1 Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob. • Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
Mounting the hood body • Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. • Hook the hood body onto the screws 12a. • Fully tighten support screws 12a • Adjust screws Vr to level the hood body. Vr 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.
Flue assembly Upper exhaust flue • Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated. • Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied. • Make sure that the outlet of the extensions pieces is aligned with the chimney outlets. Lower exhaust flue • Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.
USE Control panel L S1 M V1 V2 S2 V3 S3 L Light Switches the lighting system on and off. S1 Led Motor running led. S2 Led Intensive speed led. S3 Led Filter Alarm indicator led. Lights up when the grease filters are saturated and flashes when the odour filters are exhausted. M Motor Switches the extractor motor on and off at low speed. Used to provide a continuos and silent air change in the presence of light cooking vapours.
MAINTENANCE Grease filters CLEANING METAL SELF-SUPPORTING GREASE FILTERS Alarm signal reset • Switch off the lights and extractor motor. • Press button V2 for at least 3 seconds, until the leds start to flash. Cleaning the filters • The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher. • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER • The filter is not washable and cannot be regenerated. It must be replaced when led S3 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on. Alarm signal reset • Switch off the lights and extractor motor. • Press button V2 for at least 3 seconds, until the leds start to flash.
Quest’apparecchio è conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettromagnetica e C.E.E. 93/68 relativa alla marcatura CE. This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/ 336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.