Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...................................................................................................................... 4 CHARACTERISTICS.............................................................................................................................................................. 5 INSTALLATION .................................................................................................................................................
Bedienungsanleitung INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE....................................................................................................................................13 CHARAKTERISTIKEN .........................................................................................................................................................14 MONTAGE.....................................................................................................................................
RECOMMENDATIONS AND SUGGESTIONS INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. • The minimum safety distance between the cooker top and the extractor hood is 650 mm. • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. • For Class I appliances, check that the domestic power supply guarantees adequate earthing.
CHARACTERISTICS 650 min. 60 740 870 1200 64 42 Dimensions 598-898 300 490 260 108 150 15 Components Ref. 1 2 2.1 2.2 9 14.1 15 14.1 Q.ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 1 Telescopic Chimney comprising: 9 1 Upper Section 1 Lower Section 1 Reducer Flange ø 150-120 mm 2.1 2 Air Outlet Connection Extension 1 Air Outlet Connection 2 Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 7.
INSTALLATION 1÷2 Wall drilling and bracket fixing 116 116 650 min. 12a 320 11 X 7.2.1 Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob. • Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
Mounting the hood body Vr • Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. • Hook the hood body onto the screws 12a. • Fully tighten support screws 12a. • Adjust screws Vr to level the hood body. 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.
ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. 7.2.1 Flue assembly Upper exhaust flue • Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.
USE L T1 T2 T3 T4 T5 F The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button . Touch control L T1 Basic functions Dual Function Indicator lights When briefly pressed it switches the lighting system on and off. When pressed for 2 seconds it starts the lighting system in “courtesy light” mode. The lamps are fed at a reduced power of approximately 5W.
Touch control T5 F Basic functions Indicator lights When pressed the motor is set to the intensive speed timed to 5 minutes. At the end of 5 minutes of intensive speed the hood starts again at the speed it was set Touch control lit to previously. In case the hood is set to the intensive speed directly from OFF-state it will then start from the first speed after 5 minutes of intensive speed. Touch control lit Metal grease filters satuWhen pressed for 4 seconds it resets the filter alarm ration alarm.
MAINTENANCE Grease filters CLEANING OF THE METAL CASSETTE FILTERS Alarm reset • Stop the motor. • Press the F -touch control for at least 4 seconds until the T1 -touch control flashes. Cleaning the filters • Filters can be washed in the dish machine. They need to be washed every 2 months or even more frequently in case of particularly intensive use of the hood. • Remove the filters one by one pushing them towards the back side of the unit and simultaneously pulling downwards.
Odour filter (Recirculation Version) This filter cannot be washed or regenerated, and must be replaced when the F touch control starts to flash, or at least once every 4 months. The alarm is only triggered when the motor is on. Enabling/Disabling the alarm signal • In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of installation or later. • Switch off the lights and the motor.