Specification Sheet

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-trac
Printed in U.S.A. ©2017 Acuity Brands Lighting, Inc. 07/21/17
2 of 2
Input Voltage 120V
Input Current (max.) 0.09A
Power Factor >0.95
T.H.D. <20%
ELECTRICAL DATA
Catalog Number
Input
Voltage
Watts
(Typical) Lumens
Efficacy
(LPW)
Rated Life
(Hours)
R600L G2 27K 80CRI SP
120V 9.5 926 98 50,000
R600L G2 27K 80CRI NFL
120V 9.5 751 79 50,000
R600L G2 27K 80CRI FL
120V 9.5 844 89 50,000
R600L G2 27K 97CRI SP
120V 9.5 695 73 50,000
R600L G2 27K 97CRI NFL
120V 9.5 563 59 50,000
R600L G2 27K 97CRI FL
120V 9.5 633 67 50,000
R600L G2 30K 97CRI SP
120V 9.5 724 76 50,000
R600L G2 30K 97CRI NFL
120V 9.5 587 62 50,000
R600L G2 30K 97CRI FL
120V 9.5 659 69 50,000
R600L G2 35K 80CRI SP
120V 9.5 984 104 50,000
R600L G2 35K 80CRI NFL
120V 9.5 798 84 50,000
R600L G2 35K 80CRI FL
120V 9.5 897 94 50,000
R600L G2 40K 90CRI SP
120V 9.5 820 86 50,000
R600L G2 40K 90CRI NFL
120V 9.5 665 70 50,000
R600L G2 40K 90CRI FL
120V 9.5 747 79 50,000
R600L G2 40K 97CRI SP
120V 9.5 753 79 50,000
R600L G2 40K 97CRI NFL
120V 9.5 610 64 50,000
R600L G2 40K 97CRI FL
120V 9.5 686 72 50,000
PERFORMANCE DATA
1
Note:
1
Performance data, including Rated Life, is based on measurements of an individual fixture operating in a 25˚C ambient.
D2.1.12G2
TRAC-LITES
10W LED
R600L G2
For 27K 80CRI fixtures, use 0.96 multiplier; for 27K 97CRI fixtures, use 0.72 multiplier; for 30K 97CRI fixtures, use 0.75 multiplier;
for 35K 80CRI fixtures, use 1.02 multiplier; for 40K 97CRI fixtures, use 0.78 multiplier.
Horizontal Aiming Angles Vertical Aiming Angles
Fixture
Beam
Type
Beam
Spread
Rated
Life CBCP
0° 30° 30° 45° 60°
MH FC L W FC L W D FC X L W FC X L W D FC X L W
SP
R600L G2
10W LED,
3000K, 80CRI
Wide Spot
18°
50000 5 0 81 5 203 1.6 1.6 132 2.2 1.9 2.0 159 3.5 2.8 1.3 449 2.0 1.3 0.9 4 206 2.3 1.7 1.5
6 141 1.9 1.9 92 2.6 2.2 2.5 102 4.3 3.5 1.6 287 2.5 1.7 1.1 5 132 2.9 2.2 1.9
7 104 2.3 2.3 67 3.0 2.6 3.0 71 5.2 4.2 1.9 200 3.0 2.0 1.4 6 92 3.5 2.6 2.2
8 79 2.6 2.6 52 3.5 3.0 3.5 52 6.1 4.9 2.3 14 7 3.5 2.3 1.6 7 67 4.0 3.0 2.6
9 63 2.9 2.9 41 3.9 3.3 4.0 40 6.9 5.6 2.6 112 4.0 2.6 1.8 8 52 4.6 3.5 3.0
NFL
R600L G2
10W LED,
3000K, 80CRI
Narrow Flood
24°
50000 19 21 3 213 1.3 1.3 13 9 1.7 1.5 2.0 60 3.5 4.0 1.7 170 2.0 1.8 1.2 2 312 1.2 1.2 1.0
4 12 0 1.7 1.7 78 2.3 2.0 2.5 38 4.3 5.0 2.2 10 9 2.5 2.3 1.5 3 13 9 1.7 1.7 1.5
5 77 2.2 2.2 50 2.9 2.5 3.0 27 5.2 6.0 2.6 75 3.0 2.7 1.8 4 78 2.3 2.3 2.0
6 53 2.6 2.6 35 3.5 3.0 3.5 20 6.1 7.0 3.0 55 3.5 3.2 2.1 5 50 2.9 2.9 2.5
7 39 3.0 3.0 25 4.1 3.5 4.0 15 6.9 8.0 3.4 42 4.0 3.6 2.4 6 35 3.5 3.5 3.0
FL
R600L G2
10W LED,
3000K, 80CRI
Flood
43°
50000 11 5 9 2 290 1.6 1.6 188 2.2 1.8 1.0 14 5 1.7 6.1 1.6 410 1.0 1.9 1.1 2 188 1.2 2.2 1.8
3 129 2.4 2.4 84 3.4 2.8 1.5 64 2.6 9.1 2.4 182 1.5 2.8 1.7 3 84 1.7 3.4 2.8
4 72 3.2 3.2 47 4.5 3.7 2.0 36 3.5 12.1 3.2 102 2.0 3.8 2.3 4 47 2.3 4.5 3.7
5 46 4.0 4.0 30 5.6 4.6 2.5 23 4.3 15.2 4.0 66 2.5 4.7 2.8 5 30 2.9 5.6 4.6
6 32 4.8 4.8 21 6.7 5.5 3.0 16 5.2 18.2 4.8 46 3.0 5.7 3.4 6 21 3.5 6.7 5.5
MH
W
L
L
Aim Point
L
X
W
Aim Point
W
Aim Point
Aiming Angle (A = 0) Aiming Angle (A = 30)
D
0
A
0
A
FOR VERTICAL AIMING ANGLES
FOR HORIZONTAL AIMING ANGLES
MH
W
L
L
Aim Point
L
X
W
Aim Point
W
Aim Point
Aiming Angle (A = 0) Aiming Angle (A = 30)
D
0
A
0
A
FOR VERTICAL AIMING ANGLES
FOR HORIZONTAL AIMING ANGLES
Vertical Aiming Angles
Horizontal Aiming Angles
CBCP • Centerbeam candlepower
FC • Footcandles at beam center (aim point)
In vertical aiming applications, aim point
(X) is determined by dividing distance from
the wall (D) by the tangent of the desired
aim angle (A) (0.5774 for 30˚, 1.0 for 45˚,
1.732 for 60˚).