Installation Sheet
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
NON-METALLIC
CABLE (NM)
ROMEX PLATE
ARMORED CABLE
(BX)
CONDUIT PLATE
& CONNECTOR
(2 ports provided for
loop-feed supply wiring if desired)
MOUNTING SCREW
PUSH-IN WIRE CONNECTOR
FIXTURE JOINER
For use with 120V, 60Hz electrical power supply only. WARNING: TO PREVENT OVERHEATING AND ELECTRICAL SHOCK DO
NOT INSTALL IN SMALL ENCLOSED SPACES. TO PREVENT ELECTRICAL SHOCK DO NOT INSTALL IN WET ENVIRONMENTS.
PRO-SERIES HALOGEN, PRO-SERIES XENON UNDERCABINET LIGHT
Juno Series Low Voltage ULH Halogen or UPX Xenon Luminaires
INSTALLATION INSTRUCTIONS
© 2016 Acuity Brands Lighting, Inc. Printed in China P5025 Rev 6/16 pg 1 of 2
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
1. Read all of these instructions before installing fixture.
2. Keep these instructions in a safe place for future reference
3. Only qualified electricians in accordance with local codes should
perform all installations.
4. WARNING: FOR HARD WIRE INSTALLATION (NM & BX) MAKE
SURE ELECTRICAL POWER SUPPLY FOR INSTALLATION
CIRCUIT IS SHUT DOWN AT ELECTRICAL SERVICE PANEL
BEFORE STARTING INSTALLATION. DO NOT RE-ENERGIZE
CIRCUIT UNTIL INSTALLATION IS FULLY COMPLETED.
5. Fixture is designed to be electrically grounded for hard wire
(NM & BX) installations. WARNING: TO PREVENT SHOCK
CLOSELY FOLLOW GROUNDING DIRECTIONS.
WAYS TO ELECTRICALLY FEED FIXTURE
Electrical power can be brought to the fixture using different
techniques:
• Non-Metallic Cable (NM) using ROMEX PLATE (provided and
mounted on fixtures).
• Armored Cable (BX) using optional CONDUIT PLATE and
die-cast aluminum electrical connector (provided loose).
• Connections can also be made using fixture knockouts
(2 & 3 lamp units) and connector supplied loose.
• Wiring module accessory ULH-DWM (sold separately) can be
used for forward mount applications if necessary to allow for
remote supply wiring.
WIRING CONNECTIONS - Non-Metallic Cable (NM)
1. Loosen screw on ROMEX PLATE and remove.
2. Push NM supply cable through rectangular wire grip in plate so
outer jacket of cable projects about 3/4˝ through plate.
3. Inside fixture are three wires with PUSH-IN WIRE CONNECTOR
fitted to each end. Carefully pull these out of fixture. Do not pull
with excessive force.
4. Using strip length guides on PUSH-IN WIRE CONNECTOR make
sure lengths of exposed wire on supply cable are correct.
5. Insert each of the three wires from the NM supply cable into each
of the three PUSH-IN WIRE CONNECTORS with respective
color wires. Black to black, white to white, and green (or bare
copper wire) to green. Make sure that feed wires are securely
gripped by the PUSH-IN WIRE CONNECTOR and that with the
exception of a bare ground wire, none of the supply wires show
exposed wire where they enter the PUSH-IN WIRE CONNECTOR.
6. Neatly push wires and PUSH-IN WIRE CONNECTORS into
opening in back of the fixture.
7. Properly engage ROMEX PLATE in back of fixture and tighten
screw. Do not over tighten screw. Make sure that lock washer is
installed under head of screw for proper grounding.
WIRING CONNECTIONS - Armored Cable (BX)
1. Loosen screw on ROMEX PLATE. Remove plate and discard.
2. Mount die-cast aluminum electrical connector to the flat side of the
CONDUIT PLATE. Securely tighten nut.
3. Push BX cable into connector. Make sure BX cable has a properly
installed plastic insulating bushing (not provided). Tighten clamp
screws securely making sure that BX cable remains fully seated in
connector during tightening.
4. Perform steps 3-7 (above, for NM cable).
NOTE: In some BX installations there may not be a separate
grounding wire provided. Grounding is achieved through the spiral
wound metal jacket of the BX cable.
NOTE: The die-cast aluminum connector can also be used with
NM cable if desired.
NOTE: 2 die-cast connectors can be used for loop feed supply
wiring (2 & 3 lamp units) if desired. (For 2nd die-cast connector,
order accessory ULH-CONN.)