Operating Guide

REV-1/15
DIMENSIONS
4” MINIATURE UNIVERSAL
IC NEW CONSTRUCTION
HOUSING
INCANDESCENT LAMPS
IC1
G3.1.0
Project:
Fixture Type:
Location:
Contact/Phone:
13 1/2"
Will expand
to 25"
(Reduces to 8 1/2"
with breakaway
feature)
12 1/4"
6"
6 3/4"
9 1/8"
ACCESSORIES
Catalog No. Description
4TSA Torsion Spring Adapter (for original style housing)
GU10-WHIP GU10 Socket Whip
To order, specify catalog number.
PRODUCT CODES
Catalog Number Input Voltage Lamp Rating (max.)
IC1 120V
A19/R14/R16/R20/PAR16/PAR20 (See reverse for max. trim rating)
PRODUCT DESCRIPTION
IC Air-Loc
®
New Construction Housing with all 4” trims complies
with IECC, Washington State and other state Energy Codes
• Double wall construction • Energy efficient, sealed inner housing
does not require separate ALG gasket • Air-Loc housing stops
infiltration and exfiltration of air, reducing heating and cooling
costs • Can be completely covered with insulation.
PRODUCT SPECIFICATIONS
Lamp Lamp ratings based on trim selected – see reverse.
Socket Medium base porcelain with nickel-plated copper screw
shell.
Trims Trim selection shown on reverse.
Labels U.L. listed for through-branch wiring, damp locations and
IP • Product thermally protected against improper use of lamps
• Union made • UL Listed/CSA certified • Trim No. 11, 12,
4101, 4102 and 4181 are wet location approved for covered
ceiling applications • Trims 14, 17 are wet location approved for
covered ceiling applications, when used with outdoor rated
lamps.
Testing All reports are based on published industry procedures;
field performance may differ from laboratory performance.
Product specifications subject to change without notice.
INSTALLATION
Real Nail 3 Bar Hangers Telescoping Real Nail
®
3 system
covered
under Patent D552,969
permits quick placement of housing
anywhere within 24” O.C. joists or suspended ceilings • Integral
T-bar notch and clip secures housing in suspended ceiling grid –
no accessory clips required • 24” expansion stop allows quick
placement of fixture in standard grid spacing • Bars scored in two
locations for fast, clean breaking, allowing housing installation
in tight applications • Bars captive to mounting frame • Edge-
mounted for extra strength • Captive bugle-headed ring shank
nail for quick one-step installation and easy removal with claw
hammer for fixture relocation • Quick-Loc slot (location identified
on the mounting frame) and oversized locking set screw lock
fixture in position • Bar hanger foot contoured to align to bottom
of construction joist • Alternate mounting holes included.
Junction Box Pre-wired junction box provided with (6)
1
2” and
(1)
3
4” knockouts, (4) Non-metallic sheathed cable connectors and
ground wire, U.L. listed/CSA certified for through-branch wiring,
maximum 8 No. 12 AWG 90˚ C branch circuit conductors (3 in,
3 out) • Junction box provided with removable access plates
• Knockouts equipped with pryout slots.
Mounting Frame 22-gauge die-formed galvanized steel
mounting frame • 9
1
8” L x 6
3
4” W, (excluding bar hangers)
• Rough-in section (junction box, mounting frame, housing and bar
hangers) fully assembled for ease of installation.
Housing Air-Loc IC housing, .032” aluminum • Inner housing
is vertically adjustable to accommodate up to a 1
3
4” ceiling
thickness.
4 1/2” CEILING CUTOUT