DIMENSIONS
5” UNIVERSAL
IC REMODEL HOUSING
INCANDESCENT LAMPS
IC20R
G2.1.1
Project:
Fixture Type:
Location:
Contact/Phone:
7 1/2"
12 1/2"
5 7/8"
PRODUCT CODES
Catalog Number Input Voltage Lamp Rating (max.)
IC20R 120V A19/BR30/PAR20/PAR30/PAR30L/R20/R30 (See reverse for max. trim rating)
ACCESSORIES
Catalog No. Description
ALG5R Air-Loc Gasket
To order, specify catalog number.
PRODUCT DESCRIPTION
IC Air-Loc
®
Remodel Housing • Energy efficient, sealed housing
• IC Remodel Housing for remodel application where back side of
ceiling is not accessible • Installs through an opening in the ceiling
from below • Secured in place by factory installed remodel
springs • Can be completely covered with insulation • When used
with Air-Loc Gasket (see accessories), stops infiltration and
exfiltration of air, reducing heating and cooling costs • Trims
shown with Air-Loc symbol do not require gasket.
PRODUCT SPECIFICATIONS
Lamp Lamp ratings based on trim selected–see reverse.
Socket Medium base porcelain with nickel-plated copper screw
shell • Drop socket with spring to accommodate certain trim
installation.
Trims Trim selection shown on reverse.
Labels U.L. listed for through-branch wiring, damp locations and
IP • Product thermally protected against improper use of lamps
• Union made • UL Listed/CSA certified • Trims 210N, 211 and
212N are wet location approved for covered ceiling applications
• Trims 215 and 216 are wet location approved for covered
ceiling applications, when used with outdoor rated lamps.
Testing All reports are based on published industry procedures;
field performance may differ from laboratory performance.
Product specifications subject to change without notice.
INSTALLATION
Junction Box Pre-wired junction box, UL listed/CSA certified for
through-branch wiring maximum 4 No. 12 AWG 90˚ C branch
circuit conductors (2 in, 2 out) • Junction box provided with
removable access plate, (5)
1
2” knockouts, (4) Non-metallic
sheathed cable connectors and ground wire • Knockouts
equipped with pryout slots.
Housing IC housing, .032” aluminum sealed for Air-Loc
Compliance • Remodel springs accommodate up to 1
1
/
8
” ceiling
thickness.
5 1/2” CEILING CUTOUT