Installation Guide

SAVE THESE INSTRUCTIONS
1300 South Wolf Road • Des Plaines, IL 60018
PHONE (847) 827-9880 • FAX (847) 827-2925 • www.junolightinggroup.com
© 2011 Juno Lighting LLC Rev 1/11 P2949 pg 1 of 2
INSTALLATION INSTRUCTIONS
JUNO TYPE MINI LED RECESSED HOUSING
MD1 – MINI DOWNLIGHTS
MG1 – MINI GIMBALS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply or secondary devices, turn off electricity at the fuse or circuit breaker box.
Note: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance
with UL 2108. Before attempting installation of any recessed lighting fixture, check your local electrical building
code. This code sets the wiring standards and installation requirements for your locality and should be understood
before starting work.
Juno Type IC fixtures are designed for direct contact with
insulating materials which are approved for this application
(Fig. 1). Fixtures may also be used in non-insulated spaces.
Note: If using MG1 Mini Gimbal in an IC application, it is
recommended that the insulation be pulled away from the
fixture to prevent insulation from falling into the room during
fixture adjustment.
Installation Instructions
Step 1. Juno Mini Downlight & Gimbal fixtures are intended
for use with any 12V AC Class 2 transformer. Note: These
fixtures consume only 5W per fixture. Refer to minimum
loading requirements of transformer selected to ensure
proper operation of fixtures. For best performance, it is
recommended that the fixture is operated with Juno TL602E
electronic transformer. Make certain power delivered to
fixtures does not exceed 12V AC. Follow all local & national
electrical codes for wiring from the transformer to the
fixtures, or from fixture to fixture if daisy-chaining (Refer
to wiring diagram).
Step 2. Cut the appropriate size circular opening in
mounting surface using a hole saw or other method.
Recommended hole size:
Mini Downlights – 2"
Mini Gimbals – 2 3/8"
Fixtures install into mounting surfaces from 1/8" to1"
thick materials.
Step 3. Route Class 2 wiring from the secondary side of the
transformer through the opening in the mounting surface. Class 2
(CL2) cable or equivalent code compliant wiring is required. Strip
secondary leads 5mm (.20") for insertion into fixture terminals.
Step 4. Remove terminal block cover located atop fixture (Fig. 2).
Insert the two secondary leads into adjacent terminals on the right
or left side of the terminal block (Fig 3). (The remaining terminals
are for daisy-chain wiring if desired.) Secondary wiring is not
polarized. Tighten terminal block screws securely to retain wires.
(4 In-lb minimum)
Figure 1
Figure 2
Figure 3
TERMINAL
BLOCK
COVER
SECONDARY LEADS
FROM TRANSFORMER
SECUREMENT
SCREW
FIELD WIRING
TERMINALS
(FOR USE WITH
18-12 AWG)