Specification

Project:
Fixture Type:
Location:
Contact/Phone:
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed
Printed in U.S.A. ©2017 Acuity Brands Lighting, Inc. Rev. 03/01/17
1 of 2
DIMENSIONS
G3.1.1
4” MINIATURE UNIVERSAL
TC NEW CONSTRUCTION
HOUSING
INCANDESCENT LAMPS
TC1 SERIES
5 3/8"
12 1/8"
13 1/2"
Will expand
to 25"
(Reduces to 8 1/2"
with breakaway
feature)
6 3/4"
9 1/8"
Real Nail 3
Real Nail 2
(S option)
4 1/2” CEILING CUTOUT
PRODUCT DESCRIPTION
TC New Construction Housing design for use in non-insulated areas
• If installed where insulation is present, the insulation must be pulled
back 3” from all sides of the TC housing.
PRODUCT SPECIFICATIONS
Lamp Lamp ratings based on trim selected – see page 2.
Socket Detachable medium base porcelain with nickel-plated copper
screw shell.
Trims Trim selection shown on page 2.
Labels UL listed for through-branch wiring, damp locations and IP
• Product thermally protected against improper use of lamps or insulation
• Union made • UL Listed/CSA certified • Trim No. 11, 12, 4101, 4102
and 4181 are wet location approved for covered ceiling applications
• Trims 14, 17 are wet location approved for covered ceiling
applications, when used with outdoor rated lamps.
Testing All reports are based on published industry procedures;
field performance may differ from laboratory performance.
Specifications subject to change without notice.
INSTALLATION
Real Nail
®
Bar Hangers Telescoping, Patented (US Patent D552,969)
Real Nail 3 and Real Nail 2 systems permits quick placement of housing
anywhere within 24” O.C. joists or suspended ceilings • Bars scored
in two locations for fast, clean breaking, allowing housing installation
in tight applications • Bars captive to mounting frame • Edge-mounted
for extra strength • Quick-Loc slot (location identified on the mounting
frame) and oversized locking set screw lock fixture in position • May be
installed either perpendicular or parallel to junction box.
Real Nail 3 Bar Hanger Integral T-bar notch and clip secures housing
in suspended ceiling grid – no accessory clips required • 24” expansion
stop allows quick placement of fixture in standard grid spacing
• Captive bugle-headed ring shank nail for quick one-step installation
and easy removal with claw hammer for fixture relocation • Bar hanger
foot contoured to align to bottom of construction joist • Alternate mount-
ing holes included.
Real Nail 2 Bar Hanger (S options) Small bar hanger foot designed
to install directly on strapping construction material • Features Real Nail
captive nail system for quick one-step installation • G2405 accessory
clips required for suspended ceiling installation.
Junction Box Pre-wired junction box provided with (5)
1
2” and (1)
3
4
knockouts, (4) Non-metallic sheathed cable connectors and ground wire,
U.L. listed/CSA certified for through-branch wiring, maximum 8 No.
12 AWG 90˚ C branch circuit conductors (4 in, 4 out) • Junction box
provided with removable access plates • Knockouts equipped with
pryout slots.
Mounting Frame 22-gauge die-formed galvanized steel mounting frame
• 9
1
8” L x 6
3
4” W, (excluding bar hangers) • Rough-in section (junction
box, mounting frame, housing and bar hangers) fully assembled for ease
of installation.
Housing TC housing, 22-gauge galvanized steel • Housing is vertically
adjustable to accommodate up to a 1
1
4” ceiling thickness.
Catalog Number Input Voltage Lamp Rating
TC1
4” Incandescent New Construction Non-IC Housing 120V R14/R16/R20/PAR16/PAR20 (See page 2 for max. trim rating)
TC1 S
4” Incandescent New Construction Non-IC Housing with smaller footprint bar hanger (Real Nail 2) 120V R14/R16/R20/PAR16/PAR20 (See page 2 for max. trim rating)
PRODUCT CODES
Catalog Number Description
4TSA
4" Housing Trim Adapter
GU10WHIP
Medium Base to GU10 Adapter
G2405
T-Bar Clips (Set of 4), for S option only
To order, specify catalog number.
Accessories
Housing and trim can be ordered together or separate, but will always ship separately.

Summary of content (2 pages)