Installation Guide

Juno Type TC & PL fixtures are designed for
installations where housing and J-Box will not
come into contact with insulation. Insulation
must be spaced 3” away from the housing
and J-Box (Fig. 1)*. Blinking light after instal-
lation indicates that improper bulb or trim is
being used or that fixture has been improperly
covered with insulation.
Step 1. Locate center of proposed open-
ing on ceiling and use template to mark
and accurately cut a 4-3/8” (for 4” hous-
ings), 5-1/2” (for 5” housings) or a 6-5/8”
(for 6” housings) opening. For sloped ceil-
ing housings, an oval hole template is
provided. (Fig. 3).
Step 2. Follow steps 1-4 under electrical
connection.
Step 3. Press housing through ceiling
opening so it is flush to ceiling (Fig. 4).
Push retention clips outwards until each
clip tab clicks into position. On some
housings, a single “T” slot clip is provided
for additional support. Insert clip through
“T” slot from inside housing, force clip
down with screwdriver until clip is seated.
Secure clip by tightening screw. (Fig. 5).
(Note: To remove housing from ceiling, push
tab on clip upward to disengage).
Step 4. Install trim using coil, leaf,
torsion, or push-in springs as provided
(Fig. 6). Remove socket paint protector
cover and install proper lamp (light bulb)
as listed on housing label.
WARNING: For your safety, read and understand instructions completely before starting installation. Before wiring to power supply, turn off
electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with UL1571, 1570 or 1598.
Before attempting installation of any recessed lighting fixture, check your local electrical building code. This code sets the wiring and installation
requirements for your locality and should be understood before starting your work.
NOTE: Use of Non-Juno trims voids Juno warranty.
TYPE TC & PL for Non-Insulated Ceilings
TYPE IC for Insulated Ceilings
Installation Steps Electrical Connection Instructions
Step 1. Provide electrical service
according to your local electrical code
to the wiring box located on the remodel
housing. Supply wire insulation must be
rated for at least 90°C.
Step 2. Remove wiring box cover.
Remove the appropriate knock-out to
connect flexible metal conduit or non-
metallic cable to wiring box with proper
connectors (by others) (Fig. 7).
Step 3. Connect supply wires to fixture
wires with proper size wire nuts (not
supplied), so as to cover all bare current-
carrying conductors. Connect black
fixture wire to hot, white fixture wire to
neutral and green fixture wire to ground
(Fig. 8).
Step 4. Place all wiring and connections
back in wiring box and replace cover.
3"
Figure 1
Figure 2
Figure 3
Black
Lamp Socket
Thermal Protector
White
120V
Figure 8
Figure 4
Figure 7
Figure 5
Figure 6
*In Canada, when insulation is present, Type IC fixtures
must be used.
Juno Type IC fixtures are designed for direct
contact with insulating materials which are
approved for this application (Fig. 2). Blinking
light after installation indicates that improper
bulb or trim is being used.
Use Juno Air-Loc Gaskets or Air-Loc Rated
Trims with Juno IC housings for additional
energy savings and to comply with
Washington State and other energy codes.
Mark means lamp contains
mercury. Follow disposal laws
See www.lamprecycle.org
Hg
JUNO
®
TYPE IC & TC REMODEL RECESSED HOUSING INSTALLATION INSTRUCTIONS
1 of 1
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-recessed
©2017 Acuity Brands Lighting, Inc Rev 3/17 P3060