Press
TAB/SYS
TAB/SYS
TAB/SYS
TAB/SYS
button for
2S
2S
2S
2S
on the initial interface to enter
SYSTEM MENU
interface, set ting and test ing of the
system parameter s , storage and servo can be completed on this interface.
■
■
■
■ Charger
Charger
Charger
Charger Setup
Setup
Setup
Setup
After setting all parameters, click “ ” to save and return to the previous interface.
① Temp.
Temp.
Temp.
Temp. &
&
&
& Fans
Fans
Fans
Fans Setup
Setup
Setup
Setup
Select
SYSTEM MENU → Charger Setup → Temperature&Fans to
enter the setup interface, after setting click “ ” to
save and return to the previous interface.
Note:
When the charger internal temperature reaches to the
ON T emperature
, the fan will boot
automatically to dissipate heat, and adjust speed automatically depends on the temperature
increasing or decreasing. When the temp. exceeds (
Shut Down – Power Reduce
), the charger will
stop increasing(temp. shown in orange) via reducing the largest power limit. When the
temp.reaches (Shut Down) temperature, the charger will shut down. [ when temp. > (Shut Down-3 ) ,
the temp. shown in red flashing ]
.
When the temp. is lower than the
ON Temperature
, the fan will
keep running within the setting time of OFF Delay Time.
1 : Charger Setup M enu
2: Temp. & Fans Setup 3: Beep
T
one S etup
4: LCD S etup 5: Output P ower S etup
6: Power S upply S etup
7: Save & Load Configuration S etup
8: Calibration
9 : Extra- Function
10: Log F iles M anage 11: Servo Test
12: Pulse Test
1 : Temperature setup
Unit :
Celsius (default), Fahrenheit
Shut Down :
60 ℃ -75 ℃ ; default : 75 ℃
Power Reduce :
5 ℃ -20 ℃ ;default:10 ℃
2 : Cooling Fans setup
ON Temperature :
30 ℃ -50 ℃ ;default:40 ℃
OFF Delay Time :
0Min-10Min;default:2Min
1
2
12
11
10
9
8
7
6
5
3
2
1
4