SYSTEM MENU Charger Setup Power Supply
to enter the setup interface.
After selecting input source, click the " " followed the option, enters the relevant power supply setting to
set the parameters, after setting click to save and return to the previous interface.
Save
Save
Save
Save &
&
&
& Load
Load
Load
Load Configuration
Configuration
Configuration
Configuration Set
Set
Set
Set up
up
up
up
Select Save
Save
Save
Save &
&
&
& Load
Load
Load
Load Config
Config
Config
Config on
SYSTEM MENU
and enter the setup interface.
Note: 1. Users can save configuration to SD card, just load via SD card if use again.
2. After loading the configuration files, in addition to
Calibration Select
, it will cover all
settings within the device.
DC Power Supply Setting
Low Voltage Limi t :
9V-48V ; default: 10V
Current Limit:
1A -65A; default: 65A
Battery Power Source Setting
Low Voltage Limit:
9V-48V; default: 10V
Current Limit:
1A-65A; default: 65A
1: Regenerative Enable
2. Regen. V oltage Limit:
9V-48V; default: 14.5V
3. Regen. Current Limit:
1A-65A; default: 10A
Tick
Regenerative enable
to active power supply
regenerative feature, enable the charger to charge
back to the power supply in the discharge process.