LD-2500 - LEAK DETECTOR JB INDUSTRIES INC.
Declaration of Conformity This is to certify that this equipment, designed by JB Industries 601 N. Farnsworth Ave., Aurora, IL 60505 USA meets the essential safety requirements of the European Union and is placed on the market accordingly.
LD-2500 HUNTER Features JB’s HUNTER combines sophisticated technology with durability for an instrument with outstanding sensitivity. • Electrochemical heated-diode sensor • “No-reset” detection of CFCs, HCFCs, and HFCs • Automatic adjustment (zeroing) to refrigerants in leak test area • Rugged, flexible probe with a foam filter for sensor protection • High/Low sensitivity and power in one switch To get the best performance from your HUNTER leak detector, please read this manual carefully before use.
How to Install the “D” Alkaline Batteries 1. Remove the battery cover by releasing the latch and sliding the cover down and off of the handle. 2. Install two “D” size alkaline batteries as shown in Figure 1. 3. Reinstall the battery cover by aligning it with the handle and sliding it up until the latch engages. When the batteries reach the end of their life, the green Low Battery indicator will start flashing.
Figure 2: Installing the sensor Using the LD-2500 HUNTER WARNING DO NOT OPERATE THIS INSTRUMENT IN THE PRESENCE OF GASOLINE, NATURAL GAS, PROPANE, OR IN ANY OTHER COMBUSTIBLE ATMOSPHERES. HOW TO FIND LEAKS NOTE: A sudden whipping of the leak detector probe or blowing into the sensor tip will affect the air flow over the sensor and cause the instrument to alarm. 1. Place tip of the leak detector probe as close as possible to the site of the suspected leak.
Cleaning the HUNTER’s Housing The JB LD-2500 HUNTER’s plastic housing can be cleaned with standard household detergent or isopropyl alcohol. Care should be taken to prevent the cleaner from entering the instrument. Since gasoline and other solvents may damage plastic, protect the unit from contact with these substances. Troubleshooting Except for batteries and the sensor, the internal parts of the LD-2500 HUNTER refrigerant leak detector are not user serviceable.
Warranty and Liability JB warranties your LD-2500 HUNTER Refrigerant Leak Detector to be free from defects of materials or workmanship for two years from the date of purchase. JB does not warrant items that deteriorate under normal use, including power cells, sensors and filters. In addition, JB does not warrant any instrument that has been subjected to misuse, negligence, or accident, or has been repaired or altered by anyone other than JB.
Special Information for Automotive Technicians Cont. At each area checked, the probe shall be moved around the location, at a rate no more than 1 to 2 inches/second (25 to 50 mm/second) and no more than 1/4 inch (5 mm) from the surface completely around the position. Slower and closer movement of the probe greatly improves the likelihood of nding a leak. 8.