Operation Manual

- 16 -
PROBLEMS CHECK LIST
PROBLEM PROBABLE CAUSE SOLUTION
Pilot will not light Gas valve may be OFF Turn the gas valve ON
Tank fuel empty Refill LPG tank
Opening blocked Clean or replace opening
Air in supply system Purge air from lines
Loose connections Check all fittings
Pilot will not stay on Debris around pilot Clean dirty area
Loose connections Tighten connections
Thermocouple bad Replace thermocouple
Gas leak in line Check connections
Lack of fuel pressure Tank near empty. Refill LPG tank.
B
If the appliance is in case of any defaults or problems of assembly or useˈplease don’t try to modify it by yourselfˈ
contact your supplier or distributor to solve it.
urner will not light Pressure is low Tank near empty. Refill LPG tank.
Opening blocked Remove and clean
Control not ON Turn valve to ON
Thermocouple bad Replace thermocouple
Pilot light assembly bent Place pilot properly
Not in correct location Position properly and retry