17 / 45 PJ05030305B
4.5 Setup [SetUp]
Used to change the initial setting.
Command code
Table 4-9 SETUP CMD
HEX
ASCII
Function
0x53
0X55R
'S'
'U'
Initial setting [SetUp]
Parameters
Data length: No regulation
Sub command table (Mandatory command only)
Table 4-10 SETUP CMD SUB
HEX
ASCII
Function
Last
Memory
Operation
Reference
0x52 0x53
'R' 'S'
Switch the external control
command protocol
No
-
0x52
0x43
‘R’
‘C’
Switch the IR code
No
It consists ofSub command+ Setting”. The Sub command consists of ASCII character two bytes.
Sub commands parameters are as follow.
Parameters when the Sub command is [0x52,0x53] : Data length 1
HEX
ASCII
Operation
0x31
1’
Compatible command system
Parameters when the Sub command is [0x52,0x43] : Data length 1
HEX
ASCII
Operation
0x30
0’
A code(0x73)
0x31
1’
B code(0x63)