Owner's Manual

Table Of Contents
4 Command control
21 / 45 PJ05030305B
Command Code
Table 4-12 PANEL ALIGNMENT(ZONE) DATA CMD
HEX
ASCII
Function
transmitting
referencing
0x50
0x52
P
R’
Data of Red [Panel Alignment(Zone)Red]
0x50 0x42
P
B
Data of Blue [Panel Alignment(Zone)Blue
Parameters
Data Length: 256
Horizontal and Vertical data of 11x11 Adjustment zone composed of binary data. Data could be -31 (0xE1) to +31(0x1F).
Data is assigned by 2 bytes and its order is from Horizontal to Vertical. The order of Adjustment zone is shown at a table below.
121 (Adjustment zone) x 2 (Horizontal / Vertical) + 13 (reserved) =256 Byte
Data No.
Horizontal position of zone
Vertical position of zone
Horizontal / Vertical
1
0
0
Horizontal
2
Vertical
3
1
0
Horizontal
4
Vertical
5
2
0
Horizontal
6
Vertical
(skip)
21
10
0
Horizontal
22
Vertical
23
0
1
Horizontal
24
Vertical
(skip)
239
9
10
Horizontal
240
Vertical
241
10
10
Horizontal
242
Vertical
243-256
Reserved
The Byte order is little endian.
When the projector is not powered on and it receives the command, the projector ignores the command and does not respond.
If the projector receives gamma data larger than 256 bytes, it is judged as invalid data and the projector does not respond.