Owner's Manual

Table Of Contents
4 Command control
24 / 45 PJ05030305B
4.9 Model status asking [MoDel]
Used for referring model status of the projector.
Command code
Table 4-15 MODEL STATUS CMD
HEX
ASCII
Function
Operation
Reference
0x4D 0x44
'M'
'D'
Model status asking [MoDel]
-
Parameters
Data length: 14
Table 4-16 MODEL STATUS CMD DATA
Parameters
0x49
0x4C
0x41
0x46
0x50
0x4A
0x20
0x2D
0x2D
0x20
0x41
0x30
(*)
(*)
I
L
A
F
P
J
SP
-
-
SP
A
0’
(*)
(*)
(*) DLA-Z1 or RS4500 = A0(0x41,0x30),
4.9.1 Reference
Use the command as shown in the following examples.
Purpose: To confirm the model status of the current projector.
(1) Transmit the data from the external controller to the projector as follows.
1: External controller
0x3F
0x89
0x01
0x4D
0x44
0x0A
'?'(Reference)
PJ
Individual : 1
'M'
'D'
End
(2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows.
2: Projector
0x06
0x89
0x01
0x4D
0x44
0x0A
ACK
PJ
Individual : 1
'M'
'D'
End
(3) The projector transmits a report of the model status to the external controller.
3: Projector
0x40
0x89
0x01
0x4D
0x44
Parameters 14 bytes
0x0A
'@'(Response)
PJ
Individual : 1
'M'
'D'
Model status
End
By the above exchange, it can be confirmed model status of the projector.