Time Code Operation Mode
Set the time code operation in [Main Menu]
B [TC/
UB] B [TC Generator].
(A P106 [ TC Generator ] )
Setting Description
Free Run The time code operates in the run
mode at all times regardless of the
recording status.
It continues to run even when the
power of the camera recorder is
turned off.
Rec Run The time code operates in the run
mode during recording. It
continues
to
run in the order of the
recorded clips as long as the SD
card is not replaced. If the SD card
is removed and recording is made
on another card, time code will be
recorded on the new card from
where it was left off in the previous
card.
Regen The time code operates in the run
mode during recording. When the
SD card is replaced, the last time
code recorded on the card is read
and recorded
on a new card so that
the time code continues in running
order.
(A P70 [Setting Time Code] )
Memo :
0
When [Main Menu] B [System] B [Record Set]
B
[Rec Mode] is set to “Interval Rec” or “Frame
Rec”, and [TC Generator] is set to “Free Run”,
Rec Run is activated.
0
When [
Main Menu
] B [System] B [Record Set]
B [Record Format] B [WFormat]/[YFormat] is
set to “AVCHD”, and [Main Menu] B [System] B
[Record Set] B [Rec Mode] is set to “Pre Rec”,
Free Run is activated.
(A P117
[ W Format ] )
(
A P118 [ Y Format ] )
Setting Time Code
Generator
Presetting the Time Code
Time code and user’s bit data generated from the
internal time code generator are recorded.
This section describes how to set [TC/UB] B [TC
Preset].
(A P106
[ TC Preset ] )
Memo :
0
When [Main Menu] B [System] B [Record Set]
B
[Record Format] B [WFrame Rate] is set to
“50p”, “50i” or “24p”, setting for “Drop” will be
disabled.
(A P118
[ W Frame Rate ] )
0
You can
configure the setting without accessing
the [TC/UB] menu screen.
(A P71 [Setting Time Code without Opening
the Menu] )
Required Settings Before Preset
1
Set [TC/UB] B [TC Generator] to
“Rec
Run
” or “Free Run”.
(A P106
[ TC Generator ] )
0
[Rec Run]:
Preset data in the time code generator
operates
in run mode during recording mode.
Set this when recording continuous time
code in connecting frames.
0
[Free Run]:
Time
code starts to operate in run mode from
the preset time in the time code generator.
Time Code and User’s Bit
69
Shooting