User Manual

Table Of Contents
Settings and Operation of the Camera
Recorder
1
Set to Camera mode.
(A P
18 [Operation Modes] )
2
Set [TC/UB] B [TC Generator
] as follows.
0
Slave device:
Select “Free Run(Ext)
”.
0
Master device:
Select “Free Run
”.
3
Set LCD monitor or viewfinder to Display 1
screen.
4
Set the master device and run the time
code.
0
When the built-in time code generator is
synchronized with the external time code
data input, the Z icon on Display 1 screen
lights up.
0
When
time code is not synchronized or time
code input is not available, the Z icon goes
out.
.
P13000K
1/100
F1. 6
0
dB
AE+6
ND 1 /6 4
12 :34 :56
Jan 24,2012
00:00: 00.00
40 30 20
10
0
5 . 6 f t
Memo :
0
The built-in time code generator will continue
operation even when the master device is
disconnected after synchronization.
0
User’s
bit will become data in the master device.
0
While the [TC] terminal is connected, the time
code may be out of synchronization when the
[A/V Set] B [Video Set] B [HDMI/SDI Out]
setting of the Master device and Slave device is
being changed.
(A P112
[ HDMI/SDI Out ] )
Setting Zebra Pattern
When the luminance level range for displaying
zebra patterns is specified, diagonal lines (zebra
pattern) are displayed at areas with the specified
luminance levels during shooting.
.
AE L
EVE
L
PUSH AUTO
ZEBRA/5
1
Set the zebra display pattern.
Select the display pattern in [LCD/VF] B
[Shooting Assist] B [Zebra].
2
Specify the brightness (luminance) level
range for displaying zebra pattern.
Specify the upper and lower limits of the
luminance level in
[LCD/VF] B [Shooting
Assist] B [Zebra] B [Top] and [Bottom].
Item Settings Options
Top Upper luminance
limit for displaying
[Zebra]
5% - 100%, Over
(in
5 % increments)
Bottom Lower luminance
limit for displaying
[Zebra]
0% - 100% (in 5 %
increments)
3
Display the zebra pattern.
Press the [ZEBRA/5]
button to display the zebra
pattern in the specified range.
.
During zebra pattern display, (zebra icon)
is displayed on the display screen in Camera
mode.
Memo :
0
“Zebra” is assigned to
[ZEBRA/5] button in
factory default.
0
“Zebra” can also be assigned to other user
buttons.
(A P38
[Assignment of Functions to User
Buttons] )
71