INSTRUCTIONS

Table Of Contents
CH1/2 Limiter Mode
For setting whether to link the limiter operation of
[CH-1] and [CH-2].
Select “Link” to link or “Separate
” to separate.
[Setting Values: Link, RSeparate]
Memo :
0
This option
is selectable when both the [AUDIO
SELECT CH-1] and [AUDIO SELECT CH-2]
selection switches are set to “AUX”, and the
[AUDIO SELECT CH-1/CH-2 AUTO/MANUAL]
selection switch is set to “AUTO” at the same
time.
This option is selectable when the [AUDIO
SELECT CH-1] selection switch is set to
“INPUT1”, the [AUDIO SELECT CH-2] selection
switch is set to “INTPUT2”, and the [AUDIO
SELECT CH-1/CH-2 AUTO/MANUAL]
selection switch is set to “AUTO” at the same
time.
In all other cases, it is fixed at “Separate”.
CH1 Limiter/CH2 Limiter
Sets the limiter operation for [CH-1] and [CH-2]
separately.
9
Threshold Level
Sets the maximum recording level of
[
CH-1] and
[CH-2] respectively.
[Setting Values: -17dBFS, -15dBFS, -12dBFS,
-9dBFS, R -6dBFS, Off]
9
Attack Time
Sets the time to activate the limiter for
[CH-1] and
[CH-2] respectively.
[Setting Values: Fast,
RMiddle, Slow]
9
Decay Time
Sets
the
time to deactivate the limiter operation for
[CH-1] and [CH-2] respectively.
[Setting Values: Fast, RMiddle, Slow]
CH3/4 Limiter Mode
For setting whether to link the limiter operation of
[CH-3] and [CH-4].
Select “Link” to link or “Separate
” to separate.
[Setting Values: Link, RSeparate]
Memo :
0
This option
is selectable when both the [AUDIO
SELECT CH-3] and [AUDIO SELECT CH-4]
selection switches are set to “AUX”, and [Audio
Set] B [CH3/4 Input Level] B [CH3]/[CH4] is set
to “Auto” at the same time.
This option is selectable when the [AUDIO
SELECT CH-3] selection switch is set to
“INPUT1”, the [AUDIO SELECT CH-4] selection
switch is set to “INTPUT2”, and [Audio Set] B
[CH3/4 Input Level] B [CH3]/[CH4] is set to
“Auto” at the same time.
In all other cases, it is fixed at “Separate”.
(A
P71 [For CH-3/CH-4] )
CH3 Limiter/CH4 Limiter
Sets the limiter operation for [CH-3] and [CH-4]
separately.
9
Threshold Level
Sets the maximum recording level of
[CH-3] and
[CH-4
] respectively.
[Setting Values: -17dBFS, -15dBFS, -12dBFS,
-9dBFS, R -6dBFS, Off]
9
Attack Time
Sets the time to activate the limiter for
[CH-3] and
[CH-4
] respectively.
[Setting Values: Fast, RMiddle, Slow]
9
Decay Time
Sets
the
time to deactivate the limiter operation for
[CH-3] and [CH-4] respectively.
[Setting Values: Fast, RMiddle, Slow]
128
A/V Set Menu
Menu Display and Detailed Settings