Solenoid interlock
AZM201-AS
EN
Fault exclusion with regard to wiring routing must be
observed.
If for a certain application the power to unlock version of
a solenoid interlock cannot be used, for this exception
an interlock with power to lock can be used if additional
safety measure need to be realised that have an
equivalent safety level.
3. Mounting
3.1 General mounting instructions
Please observe the relevant requirements of the
standards ISO 12100, ISO 14119 and ISO 14120.
To mount the solenoid interlock, two mounting holes for M6 screws
with washers (washers included in delivery) are provided in the device.
The solenoid interlock must not be used as an end stop. Any mounting
position. The mounting position however must be chosen so that the
ingress of dirt and soiling in the used opening is avoided. The unused
actuator opening must be sealed by means of the dust-proof flap
(included in delivery).
Minimum distance between two solenoid interlocks
as well as other systems with same frequency (125 kHz): 100 mm.
Mounting of the actuator
Refer to the mounting instructions manual for the corresponding
actuator.
The actuator must be permanently fitted to the safety guards
and protected against displacement by suitable measures
(tamperproof screws, gluing, drilling of the screw heads).
3.2 Manual release
For the machine set-up, the solenoid interlock can be unlocked in a de-
energised condition. After opening of the plastic flap "A" (refer to image
"Dimensions"), the triangular key must be turned clockwise to bring the
blocking bolt in unlocking condition. The normal locking function is only
restored after the triangular key has been returned to its original position.
Caution: do not turn beyond the latching point!
After being put into operation, the manual release must be secured by
closing the plastic flap "A" and affixing the seal, which is included in
delivery.
Component
ready for operation
Component
not ready for operation
3.3 Dimensions
All measurements in mm.
40
220
155,5
5
6,5
32,5
7,5
20 1
±
50
15,5
M12
13,3
38
3,3
AS-i
Fault
Status
89
7,7
150
(B)
A
Key
A: Manual release
B: Active RFID area
Metal parts and magnetic fields in the lateral RFID area of
the solenoid interlock and the actuator can influence the
switching distance or lead to malfunctions.
3.4 Retrofit kit for Manual release/Emergency exit