Time meter CODIX 543
(CODIX 544: Operating mode time meter)
1. Description
• 6 digit time meter with SET/RESET function
• Red LED display, character height 14 mm
• Display range from 0 to 999 999
• Leading zeros suppression
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Programming via two setting keys on the
front side
• During programming, the display guides the
user with text prompts
• Time meter operating modes
– Counting while INP B is inactive (GAtE.Lo)
– Counting while INP B is active (GatE.hi)
– Count Start/Stop with INP B edge (Inb.Inb)
– Count Start with INP A edge, count Stop-
with INP B edge (InA.Inb)
• Counting ranges h; min; s; h.min.s
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
• Optional optocoupler output
english
4.3 Multitplying factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0“ is not accepted!
4.5 Decimal point
The decimal point defines the
resolution
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to
4 decimal places. „0“ is not
accepted!
4.4 Dividing factor
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
B
4.2 Switching on the 30 Hz filter
30 Hz filter off (f
max
)
30 Hz filter on
4.6 Display mode
Value conversion and
display in 1/s
Value conversion and
display in 1/min
4.7 Max. time to wait until „0“ is displayed
This parameter indicates, how long it takes,
when measuring is active, until „0“ is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
4.8 End of programming
The programming routine is
repeated once more. The
values set until now can be
checked and modified.
The programming routine
wil be left and all values set
will be stored as new pa-
rameters.
Afterwards the device is
ready for operation.