User manual

When ending the programme via
END.PRG. YES the counter contents are
reset.
No
count pulses, frequencies or times are
detected or measured whilst programming
is taking place.
7.8 Programming menu
Factory settings are highlighted in grey
7.8.1 Select language
Main menu: Select language
Help Text
Help Text ON
Help Text OFF
Select language for Help Text
English
German (Deutsch)
When ‘Help Text ON’ is selected, a
running text in English or German
automatically appears after 3 sec. in the
display. This provides an explanation of
the menu item. Once a running text has
started, it can be cancelled by pressing
any key.
7.8.2 Setting the Basic Function
Main menu: Basic function
Basic Function
Pulse counter (7.9.3)
Timer/Hour meter
(7.9.5)
Tacho/Frequency meter (7.9.4)
Changing the basic function causes all
parameters to be reset to factory settings.
7.8.3 Pulse Counter
7.8.3.1 Main menu for the Signal and Control
inputs
Main menu for programming the
signal and control inputs
Input polarity
P
NP: switching to Plus
for all inputs in common
NPN: switching to 0 V
f
or all inputs in common
Filter for signal inputs INP A
and INP B
Maximum count frequency
Damped to approx. 30 Hz
(for control with mechanical
contacts)
Count Input mode
(See also under 15.)
Count/Direction control
INP A: count input
INP B: count direction input
Differential counting [A – B]
INP A: count input add
INP B: count input sub
Totalising [A + B]
INP A: count input add
INP B: count input add
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature with pulse
doubling (x2)
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A will be
counted
Quadrature x4
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A and
INP B will be counted.
Ratio measurement [A / B]
INP A: count input A
INP B: count input B
Percentage differential
counting
[(A – B) / A in %]
INP A: count input A
INP B: count input B
User input 1
User input 2
When the MPI input is activated
the display is “frozen” and
remains “frozen” until the MPI
input is deactivated.
e
n
g
l
i
s
h
Page 7