User manual

Internally the preset counter
c
ontinues counting.
When the MPI input is activated
the current count value for the
p
reset that has just been
s
elected will be adopted as the
new preset value.
(See also 8.2.2)
W
hen the MPI input is activated
the preset counter will be set to
the value specified in the
parameter SETPT. (See also 8.3)
Lock input
When the Lock input is activated,
the programming is inhibited.
When the Lock input is activated,
the setting of the preset values is
inhibited.
When the Lock input is activated,
the setting of the preset values
and the programming are both
inhibited.
7.8.3.2 Main menu for Output operations
Main menu for determining the
operation of the outputs
Output operation
(See also under 18.)
Count mode ADDING
Outputs active when count status
>
preset value
Reset to zero
Count mode SUBTRACTING
Output 1 active when
count status
<
preset value 1
Output 2 active when
count status <
0
Reset to preset 2
Count mode ADDING with
automatic reset
Output 1 active when count
status
>
preset value 1
Output 2 (timed signal) active
when count status = preset value
2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic reset
Output 1 active when count
status
<
preset value 1
Output 2 (timed signal) active
w
hen count status = 0
Automatic reset to preset 2 when
c
ount status = 0
Reset to preset 2
C
ount mode ADDING with
a
utomatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset 2
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter
>
preset 1
Manual reset sets both counters
to zero.
Electrical reset sets only the
main counter to zero.
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset 2 when
main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter
>
preset 1
Manual reset sets main counter
to preset value 2 , batch counter
to zero
Electrical reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter
>
preset value 1
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
Page 8