User manual

when main counter = zero
A
utomatic reset to preset value 2
when main counter = zero
T
otal counter counts (sub from
preset value 1) all count pulses
from main counter
Output 1 active when Total
counter
< zero
Manual reset sets both counters
to the preset values
Electrical reset sets only main
counter to preset value 2
Tracking Preset mode
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero
Preset 1 relative to Preset 2
Tracking Preset mode with
automatic reset
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero.
Automatic reset to zero when
main counter = preset value 2.
Preset 1 relative to Preset 2
For the subtracting modes (SUB, SUBAR,
SUBBAT and SUBTOT), a „Reset“ (via the
key or the input) resets the counter/the
time counter to a new preset value 2.
7.8.3.3 Main menu for configuration
Main menu for matching the
input pulses to the display.
Multiplication factor
can be programmed from
00.0001 to 99.9999 The setting
00.0000 will not be accepted.
Division factor
can be programmed from
01.0000 to 99.9999
A setting < 01.0000 will not be
accepted.
Decimal point setting
(only optical function)
0 no decimal place
0.0 1 decimal place
0.00 2 decimal places
0.000 3 decimal places
0.0000 4 decimal places
0.00000 5 decimal places
Set value
Set value can be programmed
from -999999 to 999999
A previously programmed
decimal point will be displayed
7.8.3.4 Main menu for reset mode
Main menu for setting the reset
mode
Reset mode
M
anual reset (reset key) and
electrical reset (reset input)
No reset possible
(reset key and reset input
inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible
(reset key)
Electrical Reset:
Always resets only the main counter.
Manual Reset:
Resets the main counter (ACTUAL) and
auxiliary counters (BATCH or TOTAL), if the
value of the main counter or the value of an
auxiliary counters is shown on the display.
7.8.3.5 Preset 1
see below 7.9.5.5
7.8.3.6 Preset 2
see below 7.9.5.6
7.8.4 Tacho/Frequency meter
7.8.4.1 Main menu for the Signal and
Control inputs
Main menu for programming the
signal and control inputs
Input polarity
PNP: switching to Plus
for all inputs in common
NPN: switching to 0 V
for all inputs in common
Filter for signal inputs INP A
and INP B
maximum count frequency
Damped to approx. 30 Hz